Extracranial internal carotid artery calcium volume measurement using computer tomography
BACKGROUND: The extent of calcium volume in the carotid arteries of contrast-based computer tomography (CT) is a valuable indicator of stroke risk. This study presents an automated, simple and fast calcium volume computation system. Since the high contrast agent can sometimes obscure the presence of...
Saved in:
Main Authors: | , , , , , , , , , , , |
---|---|
Format: | Article |
Published: |
Edizioni Minerva Medica
2017
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/81061/ http://dx.doi.org/10.23736/S0392-9590.17.03811-1 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.81061 |
---|---|
record_format |
eprints |
spelling |
my.utm.810612019-07-24T03:06:41Z http://eprints.utm.my/id/eprint/81061/ Extracranial internal carotid artery calcium volume measurement using computer tomography Baradaran, H. Ng., C. R. Gupta, A. Noor, N. M. Al-Dasuqi, K. W. Mtui, E. E. Rijal, O. M. Giannopoulos, A. Nicolaides, A. Laird, J. R. Saba, L. Suri, J. S. T Technology (General) BACKGROUND: The extent of calcium volume in the carotid arteries of contrast-based computer tomography (CT) is a valuable indicator of stroke risk. This study presents an automated, simple and fast calcium volume computation system. Since the high contrast agent can sometimes obscure the presence of calcium in the CT slices, it is therefore necessary to identify these slices before the corrected volume can be estimated. METHODS: The system typically consists of segmenting the calcium region from the CT scan into slices based on Hounsfield Unit-based threshold, and subsequently computing the summation of the calcium areas in each slice. However, when the carotid volume has intermittently higher concentration of contrast agent, a dependable approach is adapted to correct the calcium region using the neighboring slices, thereby estimating the correct volume. Furthermore, mitigation is provided following the regulatory constraints by changing the system to semi-automated criteria as a fall back solution. We evaluate the automated and semi-automated techniques using completely manual calcium volumes computed based on the manual tracings by the neuroradiologist. RESULT S: A total of 64 patients with calcified plaque in the internal carotid artery were analyzed. Using the above algorithm, our automated and semi-automated system yields correlation coefficients (CC) of 0.89 and 0.96 against first manual readings and 0.90 and 0.96 against second manual readings, respectively. Using the t-test, there was no significant difference between the automated and semi-automated methods against manual. The intra-observer reliability was excellent with CC 0.98. CONCLUSIONS: Compared to automated method, the semi-automated method for calcium volume is acceptable and closer to manual strategy for calcium volume. Further work evaluating and confirming the performance of our semi-automated protocol is now warranted. Edizioni Minerva Medica 2017 Article PeerReviewed Baradaran, H. and Ng., C. R. and Gupta, A. and Noor, N. M. and Al-Dasuqi, K. W. and Mtui, E. E. and Rijal, O. M. and Giannopoulos, A. and Nicolaides, A. and Laird, J. R. and Saba, L. and Suri, J. S. (2017) Extracranial internal carotid artery calcium volume measurement using computer tomography. International Angiology, 36 (5). pp. 445-461. ISSN 0392-9590 http://dx.doi.org/10.23736/S0392-9590.17.03811-1 DOI:10.23736/S0392-9590.17.03811-1 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
T Technology (General) |
spellingShingle |
T Technology (General) Baradaran, H. Ng., C. R. Gupta, A. Noor, N. M. Al-Dasuqi, K. W. Mtui, E. E. Rijal, O. M. Giannopoulos, A. Nicolaides, A. Laird, J. R. Saba, L. Suri, J. S. Extracranial internal carotid artery calcium volume measurement using computer tomography |
description |
BACKGROUND: The extent of calcium volume in the carotid arteries of contrast-based computer tomography (CT) is a valuable indicator of stroke risk. This study presents an automated, simple and fast calcium volume computation system. Since the high contrast agent can sometimes obscure the presence of calcium in the CT slices, it is therefore necessary to identify these slices before the corrected volume can be estimated. METHODS: The system typically consists of segmenting the calcium region from the CT scan into slices based on Hounsfield Unit-based threshold, and subsequently computing the summation of the calcium areas in each slice. However, when the carotid volume has intermittently higher concentration of contrast agent, a dependable approach is adapted to correct the calcium region using the neighboring slices, thereby estimating the correct volume. Furthermore, mitigation is provided following the regulatory constraints by changing the system to semi-automated criteria as a fall back solution. We evaluate the automated and semi-automated techniques using completely manual calcium volumes computed based on the manual tracings by the neuroradiologist. RESULT S: A total of 64 patients with calcified plaque in the internal carotid artery were analyzed. Using the above algorithm, our automated and semi-automated system yields correlation coefficients (CC) of 0.89 and 0.96 against first manual readings and 0.90 and 0.96 against second manual readings, respectively. Using the t-test, there was no significant difference between the automated and semi-automated methods against manual. The intra-observer reliability was excellent with CC 0.98. CONCLUSIONS: Compared to automated method, the semi-automated method for calcium volume is acceptable and closer to manual strategy for calcium volume. Further work evaluating and confirming the performance of our semi-automated protocol is now warranted. |
format |
Article |
author |
Baradaran, H. Ng., C. R. Gupta, A. Noor, N. M. Al-Dasuqi, K. W. Mtui, E. E. Rijal, O. M. Giannopoulos, A. Nicolaides, A. Laird, J. R. Saba, L. Suri, J. S. |
author_facet |
Baradaran, H. Ng., C. R. Gupta, A. Noor, N. M. Al-Dasuqi, K. W. Mtui, E. E. Rijal, O. M. Giannopoulos, A. Nicolaides, A. Laird, J. R. Saba, L. Suri, J. S. |
author_sort |
Baradaran, H. |
title |
Extracranial internal carotid artery calcium volume measurement using computer tomography |
title_short |
Extracranial internal carotid artery calcium volume measurement using computer tomography |
title_full |
Extracranial internal carotid artery calcium volume measurement using computer tomography |
title_fullStr |
Extracranial internal carotid artery calcium volume measurement using computer tomography |
title_full_unstemmed |
Extracranial internal carotid artery calcium volume measurement using computer tomography |
title_sort |
extracranial internal carotid artery calcium volume measurement using computer tomography |
publisher |
Edizioni Minerva Medica |
publishDate |
2017 |
url |
http://eprints.utm.my/id/eprint/81061/ http://dx.doi.org/10.23736/S0392-9590.17.03811-1 |
_version_ |
1643658598985760768 |
score |
13.214268 |