Extracranial internal carotid artery calcium volume measurement using computer tomography

BACKGROUND: The extent of calcium volume in the carotid arteries of contrast-based computer tomography (CT) is a valuable indicator of stroke risk. This study presents an automated, simple and fast calcium volume computation system. Since the high contrast agent can sometimes obscure the presence of...

Full description

Saved in:
Bibliographic Details
Main Authors: Baradaran, H., Ng., C. R., Gupta, A., Noor, N. M., Al-Dasuqi, K. W., Mtui, E. E., Rijal, O. M., Giannopoulos, A., Nicolaides, A., Laird, J. R., Saba, L., Suri, J. S.
Format: Article
Published: Edizioni Minerva Medica 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/81061/
http://dx.doi.org/10.23736/S0392-9590.17.03811-1
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.81061
record_format eprints
spelling my.utm.810612019-07-24T03:06:41Z http://eprints.utm.my/id/eprint/81061/ Extracranial internal carotid artery calcium volume measurement using computer tomography Baradaran, H. Ng., C. R. Gupta, A. Noor, N. M. Al-Dasuqi, K. W. Mtui, E. E. Rijal, O. M. Giannopoulos, A. Nicolaides, A. Laird, J. R. Saba, L. Suri, J. S. T Technology (General) BACKGROUND: The extent of calcium volume in the carotid arteries of contrast-based computer tomography (CT) is a valuable indicator of stroke risk. This study presents an automated, simple and fast calcium volume computation system. Since the high contrast agent can sometimes obscure the presence of calcium in the CT slices, it is therefore necessary to identify these slices before the corrected volume can be estimated. METHODS: The system typically consists of segmenting the calcium region from the CT scan into slices based on Hounsfield Unit-based threshold, and subsequently computing the summation of the calcium areas in each slice. However, when the carotid volume has intermittently higher concentration of contrast agent, a dependable approach is adapted to correct the calcium region using the neighboring slices, thereby estimating the correct volume. Furthermore, mitigation is provided following the regulatory constraints by changing the system to semi-automated criteria as a fall back solution. We evaluate the automated and semi-automated techniques using completely manual calcium volumes computed based on the manual tracings by the neuroradiologist. RESULT S: A total of 64 patients with calcified plaque in the internal carotid artery were analyzed. Using the above algorithm, our automated and semi-automated system yields correlation coefficients (CC) of 0.89 and 0.96 against first manual readings and 0.90 and 0.96 against second manual readings, respectively. Using the t-test, there was no significant difference between the automated and semi-automated methods against manual. The intra-observer reliability was excellent with CC 0.98. CONCLUSIONS: Compared to automated method, the semi-automated method for calcium volume is acceptable and closer to manual strategy for calcium volume. Further work evaluating and confirming the performance of our semi-automated protocol is now warranted. Edizioni Minerva Medica 2017 Article PeerReviewed Baradaran, H. and Ng., C. R. and Gupta, A. and Noor, N. M. and Al-Dasuqi, K. W. and Mtui, E. E. and Rijal, O. M. and Giannopoulos, A. and Nicolaides, A. and Laird, J. R. and Saba, L. and Suri, J. S. (2017) Extracranial internal carotid artery calcium volume measurement using computer tomography. International Angiology, 36 (5). pp. 445-461. ISSN 0392-9590 http://dx.doi.org/10.23736/S0392-9590.17.03811-1 DOI:10.23736/S0392-9590.17.03811-1
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic T Technology (General)
spellingShingle T Technology (General)
Baradaran, H.
Ng., C. R.
Gupta, A.
Noor, N. M.
Al-Dasuqi, K. W.
Mtui, E. E.
Rijal, O. M.
Giannopoulos, A.
Nicolaides, A.
Laird, J. R.
Saba, L.
Suri, J. S.
Extracranial internal carotid artery calcium volume measurement using computer tomography
description BACKGROUND: The extent of calcium volume in the carotid arteries of contrast-based computer tomography (CT) is a valuable indicator of stroke risk. This study presents an automated, simple and fast calcium volume computation system. Since the high contrast agent can sometimes obscure the presence of calcium in the CT slices, it is therefore necessary to identify these slices before the corrected volume can be estimated. METHODS: The system typically consists of segmenting the calcium region from the CT scan into slices based on Hounsfield Unit-based threshold, and subsequently computing the summation of the calcium areas in each slice. However, when the carotid volume has intermittently higher concentration of contrast agent, a dependable approach is adapted to correct the calcium region using the neighboring slices, thereby estimating the correct volume. Furthermore, mitigation is provided following the regulatory constraints by changing the system to semi-automated criteria as a fall back solution. We evaluate the automated and semi-automated techniques using completely manual calcium volumes computed based on the manual tracings by the neuroradiologist. RESULT S: A total of 64 patients with calcified plaque in the internal carotid artery were analyzed. Using the above algorithm, our automated and semi-automated system yields correlation coefficients (CC) of 0.89 and 0.96 against first manual readings and 0.90 and 0.96 against second manual readings, respectively. Using the t-test, there was no significant difference between the automated and semi-automated methods against manual. The intra-observer reliability was excellent with CC 0.98. CONCLUSIONS: Compared to automated method, the semi-automated method for calcium volume is acceptable and closer to manual strategy for calcium volume. Further work evaluating and confirming the performance of our semi-automated protocol is now warranted.
format Article
author Baradaran, H.
Ng., C. R.
Gupta, A.
Noor, N. M.
Al-Dasuqi, K. W.
Mtui, E. E.
Rijal, O. M.
Giannopoulos, A.
Nicolaides, A.
Laird, J. R.
Saba, L.
Suri, J. S.
author_facet Baradaran, H.
Ng., C. R.
Gupta, A.
Noor, N. M.
Al-Dasuqi, K. W.
Mtui, E. E.
Rijal, O. M.
Giannopoulos, A.
Nicolaides, A.
Laird, J. R.
Saba, L.
Suri, J. S.
author_sort Baradaran, H.
title Extracranial internal carotid artery calcium volume measurement using computer tomography
title_short Extracranial internal carotid artery calcium volume measurement using computer tomography
title_full Extracranial internal carotid artery calcium volume measurement using computer tomography
title_fullStr Extracranial internal carotid artery calcium volume measurement using computer tomography
title_full_unstemmed Extracranial internal carotid artery calcium volume measurement using computer tomography
title_sort extracranial internal carotid artery calcium volume measurement using computer tomography
publisher Edizioni Minerva Medica
publishDate 2017
url http://eprints.utm.my/id/eprint/81061/
http://dx.doi.org/10.23736/S0392-9590.17.03811-1
_version_ 1643658598985760768
score 13.214268