Assessing stir bar sorptive extraction for triazine herbicides extraction by using a central composite design approach

A (PDMS)-coated stir bar was prepared for a glass jacket-free stir bar sorptive extraction (SBSE) configuration by adhesion technique for the extraction of triazine herbicides prior to quantification using a gas chromatography-flame ionization detector (GC-FID). A central composite design (CCD) was...

Full description

Saved in:
Bibliographic Details
Main Authors: Abidin, N. A. Z., Abdullah, M. P., Al-Qaim, F. F., Khalik, W. M. A. W. M., Othman, M. R.
Format: Article
Language:English
Published: Malaysian Society of Analytical Sciences 2018
Subjects:
Online Access:http://eprints.utm.my/id/eprint/79811/1/FouadFadhilAlQaim2018_AssessingStirBarSorptiveExtraction.pdf
http://eprints.utm.my/id/eprint/79811/
http://dx.doi.org/10.17576/mjas-2018-2201-06
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.79811
record_format eprints
spelling my.utm.798112019-01-28T06:56:04Z http://eprints.utm.my/id/eprint/79811/ Assessing stir bar sorptive extraction for triazine herbicides extraction by using a central composite design approach Abidin, N. A. Z. Abdullah, M. P. Al-Qaim, F. F. Khalik, W. M. A. W. M. Othman, M. R. T Technology (General) A (PDMS)-coated stir bar was prepared for a glass jacket-free stir bar sorptive extraction (SBSE) configuration by adhesion technique for the extraction of triazine herbicides prior to quantification using a gas chromatography-flame ionization detector (GC-FID). A central composite design (CCD) was used in the optimization of extraction and desorption conditions. At optimum conditions, values of factors were set as pH 8.5, with no addition of NaCl, for 25 minutes of extraction time, and 24 minutes of desorption time. Under optimal experimental conditions, the proposed method has linear ranges at 0.1 – 100 µgL-1 with correlation of determination (R2), ranging from 0.9991 – 0.9995, respectively. The limit of detection (LODs) and limit of quantification (LOQs) of three triazines were found to be ranging from 0.015 – 0.023 µgL-1 and 0.047 – 0.060 µgL-1, respectively. Malaysian Society of Analytical Sciences 2018-02 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/79811/1/FouadFadhilAlQaim2018_AssessingStirBarSorptiveExtraction.pdf Abidin, N. A. Z. and Abdullah, M. P. and Al-Qaim, F. F. and Khalik, W. M. A. W. M. and Othman, M. R. (2018) Assessing stir bar sorptive extraction for triazine herbicides extraction by using a central composite design approach. Malaysian Journal of Analytical Sciences, 22 (1). ISSN 1394-2506 http://dx.doi.org/10.17576/mjas-2018-2201-06 DOI:10.17576/mjas-2018-2201-06
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic T Technology (General)
spellingShingle T Technology (General)
Abidin, N. A. Z.
Abdullah, M. P.
Al-Qaim, F. F.
Khalik, W. M. A. W. M.
Othman, M. R.
Assessing stir bar sorptive extraction for triazine herbicides extraction by using a central composite design approach
description A (PDMS)-coated stir bar was prepared for a glass jacket-free stir bar sorptive extraction (SBSE) configuration by adhesion technique for the extraction of triazine herbicides prior to quantification using a gas chromatography-flame ionization detector (GC-FID). A central composite design (CCD) was used in the optimization of extraction and desorption conditions. At optimum conditions, values of factors were set as pH 8.5, with no addition of NaCl, for 25 minutes of extraction time, and 24 minutes of desorption time. Under optimal experimental conditions, the proposed method has linear ranges at 0.1 – 100 µgL-1 with correlation of determination (R2), ranging from 0.9991 – 0.9995, respectively. The limit of detection (LODs) and limit of quantification (LOQs) of three triazines were found to be ranging from 0.015 – 0.023 µgL-1 and 0.047 – 0.060 µgL-1, respectively.
format Article
author Abidin, N. A. Z.
Abdullah, M. P.
Al-Qaim, F. F.
Khalik, W. M. A. W. M.
Othman, M. R.
author_facet Abidin, N. A. Z.
Abdullah, M. P.
Al-Qaim, F. F.
Khalik, W. M. A. W. M.
Othman, M. R.
author_sort Abidin, N. A. Z.
title Assessing stir bar sorptive extraction for triazine herbicides extraction by using a central composite design approach
title_short Assessing stir bar sorptive extraction for triazine herbicides extraction by using a central composite design approach
title_full Assessing stir bar sorptive extraction for triazine herbicides extraction by using a central composite design approach
title_fullStr Assessing stir bar sorptive extraction for triazine herbicides extraction by using a central composite design approach
title_full_unstemmed Assessing stir bar sorptive extraction for triazine herbicides extraction by using a central composite design approach
title_sort assessing stir bar sorptive extraction for triazine herbicides extraction by using a central composite design approach
publisher Malaysian Society of Analytical Sciences
publishDate 2018