Gas analysis technique for gas insulated switchgear condition monitoring and diagnosis

Sulphur hexafluoride gas insulated switchgear (GIS) is widely used in electrical power supply system and therefore needs regular preventive maintenance. Usual diagnosis methods used are based on acoustic, optical, electrical and ultra high frequency techniques. A new method with great potential is u...

Full description

Saved in:
Bibliographic Details
Main Author: Ibrahim, Visa Musa
Format: Thesis
Language:English
Published: 2018
Subjects:
Online Access:http://eprints.utm.my/id/eprint/79570/1/VisaMusaIbrahimPFKE2018.pdf
http://eprints.utm.my/id/eprint/79570/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.79570
record_format eprints
spelling my.utm.795702018-10-31T13:00:03Z http://eprints.utm.my/id/eprint/79570/ Gas analysis technique for gas insulated switchgear condition monitoring and diagnosis Ibrahim, Visa Musa TK Electrical engineering. Electronics Nuclear engineering Sulphur hexafluoride gas insulated switchgear (GIS) is widely used in electrical power supply system and therefore needs regular preventive maintenance. Usual diagnosis methods used are based on acoustic, optical, electrical and ultra high frequency techniques. A new method with great potential is using gas by-products analysis. Previous gas by-products research is confined to a plane-plane electrode instead of typical coaxial GIS configuration, a limited number of defect types and the by-products analysis using gas chromatography. In this thesis, partial discharge experiments using a purposely designed coaxial GIS chamber were carried out to expand the diagnosis database for a new set of simulated defects represented by three categories, namely sole defect, hybrid defect, and material dependent defect. A total of eight defects namely, free conducting particle, electrode to dielectric void, electrode protrusion, fixed particle aluminium on spacer, fixed copper particle on spacer, electrode protrusion-fixed copper particle hybrid, electrode protrusion-free copper particle hybrid, and electrode to dielectric void-free copper particle hybrid were simulated. In each experiment lasting up to 50 hours, continually applied voltage at 0.2 MPa pressure, samples of gas by-products were taken at 10 hour intervals for an off-line Fourier transform infrared spectrometer gas analyses. A total of 12 gas by-products due to partial discharge activity in all defects were detected. Arranged according to significance, these are hexafluoroethane, sulphur dioxide, sulfuryl fluoride, octafluoropropane, silicon tetrafluoride, thionyl fluoride, carbon monoxide, disulfur decafluoride, hydrogen fluoride, tetrafluoromethane, carbonyl sulphide and tetrafluoride. Arranged according to significance, the most harmful gases are produced by the defects such as electrode protrusion-fixed copper particle hybrid, fixed copper particle, electrode protrusion-free copper particle hybrid and electrode protrusion. The type, number, concentration and chemical stability of by-product gases are found to be closely correlated to the type of defect. Further analyses using pattern recognition with eight algorithms based on the presence and concentration of the gas by-products were carried out. The random forest algorithm successfully recognises a given defect with an accuracy of 87.5%. The performance of the random forest algorithm is 1.5 times better than the next best algorithm. This research illustrates the feasibility and applicability of an effective GIS diagnostic using gas by-products analyses, in particular, using the random forest pattern recognition. 2018 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/79570/1/VisaMusaIbrahimPFKE2018.pdf Ibrahim, Visa Musa (2018) Gas analysis technique for gas insulated switchgear condition monitoring and diagnosis. PhD thesis, Universiti Teknologi Malaysia, Faculty of Electrical Engineering.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Ibrahim, Visa Musa
Gas analysis technique for gas insulated switchgear condition monitoring and diagnosis
description Sulphur hexafluoride gas insulated switchgear (GIS) is widely used in electrical power supply system and therefore needs regular preventive maintenance. Usual diagnosis methods used are based on acoustic, optical, electrical and ultra high frequency techniques. A new method with great potential is using gas by-products analysis. Previous gas by-products research is confined to a plane-plane electrode instead of typical coaxial GIS configuration, a limited number of defect types and the by-products analysis using gas chromatography. In this thesis, partial discharge experiments using a purposely designed coaxial GIS chamber were carried out to expand the diagnosis database for a new set of simulated defects represented by three categories, namely sole defect, hybrid defect, and material dependent defect. A total of eight defects namely, free conducting particle, electrode to dielectric void, electrode protrusion, fixed particle aluminium on spacer, fixed copper particle on spacer, electrode protrusion-fixed copper particle hybrid, electrode protrusion-free copper particle hybrid, and electrode to dielectric void-free copper particle hybrid were simulated. In each experiment lasting up to 50 hours, continually applied voltage at 0.2 MPa pressure, samples of gas by-products were taken at 10 hour intervals for an off-line Fourier transform infrared spectrometer gas analyses. A total of 12 gas by-products due to partial discharge activity in all defects were detected. Arranged according to significance, these are hexafluoroethane, sulphur dioxide, sulfuryl fluoride, octafluoropropane, silicon tetrafluoride, thionyl fluoride, carbon monoxide, disulfur decafluoride, hydrogen fluoride, tetrafluoromethane, carbonyl sulphide and tetrafluoride. Arranged according to significance, the most harmful gases are produced by the defects such as electrode protrusion-fixed copper particle hybrid, fixed copper particle, electrode protrusion-free copper particle hybrid and electrode protrusion. The type, number, concentration and chemical stability of by-product gases are found to be closely correlated to the type of defect. Further analyses using pattern recognition with eight algorithms based on the presence and concentration of the gas by-products were carried out. The random forest algorithm successfully recognises a given defect with an accuracy of 87.5%. The performance of the random forest algorithm is 1.5 times better than the next best algorithm. This research illustrates the feasibility and applicability of an effective GIS diagnostic using gas by-products analyses, in particular, using the random forest pattern recognition.
format Thesis
author Ibrahim, Visa Musa
author_facet Ibrahim, Visa Musa
author_sort Ibrahim, Visa Musa
title Gas analysis technique for gas insulated switchgear condition monitoring and diagnosis
title_short Gas analysis technique for gas insulated switchgear condition monitoring and diagnosis
title_full Gas analysis technique for gas insulated switchgear condition monitoring and diagnosis
title_fullStr Gas analysis technique for gas insulated switchgear condition monitoring and diagnosis
title_full_unstemmed Gas analysis technique for gas insulated switchgear condition monitoring and diagnosis
title_sort gas analysis technique for gas insulated switchgear condition monitoring and diagnosis
publishDate 2018
url http://eprints.utm.my/id/eprint/79570/1/VisaMusaIbrahimPFKE2018.pdf
http://eprints.utm.my/id/eprint/79570/
_version_ 1643658234111721472
score 13.159267