Wide range analysis of ozone gas concentration in ultraviolet region

The purpose of this research is to investigate the development of optical gas sensor employing absorption spectroscopy technique for ozone concentration measurement. Additionally, wide range analysis has been conducted to improve range of ozone concentration measurement using ultraviolet light absor...

Full description

Saved in:
Bibliographic Details
Main Author: Yaacob, Maslina
Format: Thesis
Language:English
Published: 2016
Subjects:
Online Access:http://eprints.utm.my/id/eprint/78749/1/MaslinaYaacobPFKE2016.pdf
http://eprints.utm.my/id/eprint/78749/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:106209
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.78749
record_format eprints
spelling my.utm.787492018-08-30T08:06:56Z http://eprints.utm.my/id/eprint/78749/ Wide range analysis of ozone gas concentration in ultraviolet region Yaacob, Maslina TK Electrical engineering. Electronics Nuclear engineering The purpose of this research is to investigate the development of optical gas sensor employing absorption spectroscopy technique for ozone concentration measurement. Additionally, wide range analysis has been conducted to improve range of ozone concentration measurement using ultraviolet light absorption. Simulation of ozone absorption cross section in ultraviolet region was conducted via Spectralcalc.com® simulator. Simulation result for ozone absorption cross section was then verified by comparison with result from previous studies, showing small percentage of difference less than 3.05 %. In addition, the simulator was also used to investigate the effect of pressure and temperature on ozone absorption cross section. Simulation result showed ozone absorption cross section to exhibit negligible effect of pressure and temperature from 0.1 atm until 2.0 atm and from 293 K until 305 K, respectively. Next, path length of gas cell that suits with detection range of ozone monitor was determined through Spectralcalc.com® simulator. Finally, transmissive type gas cell is fabricated at optimum length of 10 cm. Based on the experiment results wide range analysis was conducted at 10 cm gas cell by consideration of less relative error of concentration. It was observed that wavelengths at 232 nm, 233 nm, 234 nm, 235 nm, 236 nm, 284 nm, 285 nm, 286 nm and 287 nm exhibit capability to measure ozone concentration using ultraviolet light absorption at high concentration value with wide range of concentration measurement from 619 ppm until 932 ppm. Of this, 285 nm was chosen due to its high resolution value at 17 ppm. The sensor exhibits fast response time and recovery time, both at 20 s. Peak of ozone absorption cross sections were observed in both experiment and simulation, located at 260.45 nm and 255.44 nm, respectively. Meanwhile, the values of peak of ozone absorption cross section were observed in experiment and simulation at 164.37 × 10-23 m2 molecule-1 and 114.86 × 10-23 m2 molecule-1, respectively. Significantly, this research has successfully demonstrated possibility of conducting wide-range analysis employing consideration of less relative error concentration. Particularly, vast improvement range of ozone concentration measurement has been achieved by wavelength selection which is far from the peak of ozone absorption cross section. 2016-06 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/78749/1/MaslinaYaacobPFKE2016.pdf Yaacob, Maslina (2016) Wide range analysis of ozone gas concentration in ultraviolet region. PhD thesis, Universiti Teknologi Malaysia, Faculty of Electrical Engineering. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:106209
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Yaacob, Maslina
Wide range analysis of ozone gas concentration in ultraviolet region
description The purpose of this research is to investigate the development of optical gas sensor employing absorption spectroscopy technique for ozone concentration measurement. Additionally, wide range analysis has been conducted to improve range of ozone concentration measurement using ultraviolet light absorption. Simulation of ozone absorption cross section in ultraviolet region was conducted via Spectralcalc.com® simulator. Simulation result for ozone absorption cross section was then verified by comparison with result from previous studies, showing small percentage of difference less than 3.05 %. In addition, the simulator was also used to investigate the effect of pressure and temperature on ozone absorption cross section. Simulation result showed ozone absorption cross section to exhibit negligible effect of pressure and temperature from 0.1 atm until 2.0 atm and from 293 K until 305 K, respectively. Next, path length of gas cell that suits with detection range of ozone monitor was determined through Spectralcalc.com® simulator. Finally, transmissive type gas cell is fabricated at optimum length of 10 cm. Based on the experiment results wide range analysis was conducted at 10 cm gas cell by consideration of less relative error of concentration. It was observed that wavelengths at 232 nm, 233 nm, 234 nm, 235 nm, 236 nm, 284 nm, 285 nm, 286 nm and 287 nm exhibit capability to measure ozone concentration using ultraviolet light absorption at high concentration value with wide range of concentration measurement from 619 ppm until 932 ppm. Of this, 285 nm was chosen due to its high resolution value at 17 ppm. The sensor exhibits fast response time and recovery time, both at 20 s. Peak of ozone absorption cross sections were observed in both experiment and simulation, located at 260.45 nm and 255.44 nm, respectively. Meanwhile, the values of peak of ozone absorption cross section were observed in experiment and simulation at 164.37 × 10-23 m2 molecule-1 and 114.86 × 10-23 m2 molecule-1, respectively. Significantly, this research has successfully demonstrated possibility of conducting wide-range analysis employing consideration of less relative error concentration. Particularly, vast improvement range of ozone concentration measurement has been achieved by wavelength selection which is far from the peak of ozone absorption cross section.
format Thesis
author Yaacob, Maslina
author_facet Yaacob, Maslina
author_sort Yaacob, Maslina
title Wide range analysis of ozone gas concentration in ultraviolet region
title_short Wide range analysis of ozone gas concentration in ultraviolet region
title_full Wide range analysis of ozone gas concentration in ultraviolet region
title_fullStr Wide range analysis of ozone gas concentration in ultraviolet region
title_full_unstemmed Wide range analysis of ozone gas concentration in ultraviolet region
title_sort wide range analysis of ozone gas concentration in ultraviolet region
publishDate 2016
url http://eprints.utm.my/id/eprint/78749/1/MaslinaYaacobPFKE2016.pdf
http://eprints.utm.my/id/eprint/78749/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:106209
_version_ 1643657992767275008