Instantaneous protection scheme for backup protection of high-voltage transmission lines

The protection scheme focused on in this study is a typical protection system used in high-voltage systems such as 132 kV, 275 kV, and 500 kV. The research will analyze the existing protection scheme for transmission lines that the power utility has implemented and will propose a new protection sche...

Full description

Saved in:
Bibliographic Details
Main Authors: Syed Nasir, Syed Norazizul, Mohd. Zin, Abdullah Asuhaimi
Format: Article
Language:English
Published: Turkiye Klinikleri Journal of Medical Sciences 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/77534/1/SyedNorazizulSyedNasir2017_InstantaneousProtectionSchemeforBackupProtectionofHighVoltage.pdf
http://eprints.utm.my/id/eprint/77534/
http://dx.doi.org/10.3906/elk-1511-9
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.77534
record_format eprints
spelling my.utm.775342018-11-30T07:09:55Z http://eprints.utm.my/id/eprint/77534/ Instantaneous protection scheme for backup protection of high-voltage transmission lines Syed Nasir, Syed Norazizul Mohd. Zin, Abdullah Asuhaimi TK Electrical engineering. Electronics Nuclear engineering The protection scheme focused on in this study is a typical protection system used in high-voltage systems such as 132 kV, 275 kV, and 500 kV. The research will analyze the existing protection scheme for transmission lines that the power utility has implemented and will propose a new protection scheme to improve the performance of the existing scheme. The existing protection scheme currently implemented by the power utility for backup protection operation has a longer fault-clearing time and no restoration time, and it does not utilize support relays. This study will focus on a backup protection operation on high-voltage overhead transmission lines, which take up communication when the main protection has failed to communicate, the relay has failed due to loss of DC supply, or the relay function itself has been blocked. Moreover, all the support relays will be utilized in order to improve the protection system. The improvement will consider three elements, which are the fault-clearing time, fast restoration time, and relay utilization. Each improvement to the protection system will have its own philosophy and concrete rationale, which have advantages or disadvantages for the transmission line. The effect of the improvement scheme will also consider the outcomes in other schemes to ensure that time coordination does not overlap. Every possibility of a fault will be analyzed in order to have a clear understanding of the effects of the three elements. CAPE software will be used as a tool for simulation and to analyze its compatibility with real applications. CAPE software is able to model a real-life transmission line and is also able to simulate faults in the tested area. The results of the simulation show that the backup protection operation improved fault-clearing time and restoration time. It also increased the network's system stability, particularly during the occurrence of maximum fault currents. Turkiye Klinikleri Journal of Medical Sciences 2017 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/77534/1/SyedNorazizulSyedNasir2017_InstantaneousProtectionSchemeforBackupProtectionofHighVoltage.pdf Syed Nasir, Syed Norazizul and Mohd. Zin, Abdullah Asuhaimi (2017) Instantaneous protection scheme for backup protection of high-voltage transmission lines. Turkish Journal of Electrical Engineering & Computer Sciences, 25 (4). pp. 3261-3272. ISSN 1300-0632 http://dx.doi.org/10.3906/elk-1511-9 DOI: 10.3906/elk-1511-9
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Syed Nasir, Syed Norazizul
Mohd. Zin, Abdullah Asuhaimi
Instantaneous protection scheme for backup protection of high-voltage transmission lines
description The protection scheme focused on in this study is a typical protection system used in high-voltage systems such as 132 kV, 275 kV, and 500 kV. The research will analyze the existing protection scheme for transmission lines that the power utility has implemented and will propose a new protection scheme to improve the performance of the existing scheme. The existing protection scheme currently implemented by the power utility for backup protection operation has a longer fault-clearing time and no restoration time, and it does not utilize support relays. This study will focus on a backup protection operation on high-voltage overhead transmission lines, which take up communication when the main protection has failed to communicate, the relay has failed due to loss of DC supply, or the relay function itself has been blocked. Moreover, all the support relays will be utilized in order to improve the protection system. The improvement will consider three elements, which are the fault-clearing time, fast restoration time, and relay utilization. Each improvement to the protection system will have its own philosophy and concrete rationale, which have advantages or disadvantages for the transmission line. The effect of the improvement scheme will also consider the outcomes in other schemes to ensure that time coordination does not overlap. Every possibility of a fault will be analyzed in order to have a clear understanding of the effects of the three elements. CAPE software will be used as a tool for simulation and to analyze its compatibility with real applications. CAPE software is able to model a real-life transmission line and is also able to simulate faults in the tested area. The results of the simulation show that the backup protection operation improved fault-clearing time and restoration time. It also increased the network's system stability, particularly during the occurrence of maximum fault currents.
format Article
author Syed Nasir, Syed Norazizul
Mohd. Zin, Abdullah Asuhaimi
author_facet Syed Nasir, Syed Norazizul
Mohd. Zin, Abdullah Asuhaimi
author_sort Syed Nasir, Syed Norazizul
title Instantaneous protection scheme for backup protection of high-voltage transmission lines
title_short Instantaneous protection scheme for backup protection of high-voltage transmission lines
title_full Instantaneous protection scheme for backup protection of high-voltage transmission lines
title_fullStr Instantaneous protection scheme for backup protection of high-voltage transmission lines
title_full_unstemmed Instantaneous protection scheme for backup protection of high-voltage transmission lines
title_sort instantaneous protection scheme for backup protection of high-voltage transmission lines
publisher Turkiye Klinikleri Journal of Medical Sciences
publishDate 2017
url http://eprints.utm.my/id/eprint/77534/1/SyedNorazizulSyedNasir2017_InstantaneousProtectionSchemeforBackupProtectionofHighVoltage.pdf
http://eprints.utm.my/id/eprint/77534/
http://dx.doi.org/10.3906/elk-1511-9
_version_ 1643657568757743616
score 13.160551