Magnetic field measurement from 132/275 KV overhead power lines

This paper presents a study on magnetic field radiated from 132/275kV overhead power lines. The magnetic field radiation from overhead power lines have become a concern to the public due to its adverse health effects such as leukemia in children. A report from World Health Organization (WHO) stated...

Full description

Saved in:
Bibliographic Details
Main Authors: Jimbin, V. S., Ahmad, N. A.
Format: Article
Published: Penerbit UTM Press 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/76754/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85008165468&doi=10.11113%2fjt.v79.7270&partnerID=40&md5=2e1aa5bcc26516d5d544fa951a5a2ce2
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.76754
record_format eprints
spelling my.utm.767542018-04-30T14:03:03Z http://eprints.utm.my/id/eprint/76754/ Magnetic field measurement from 132/275 KV overhead power lines Jimbin, V. S. Ahmad, N. A. T Technology (General) This paper presents a study on magnetic field radiated from 132/275kV overhead power lines. The magnetic field radiation from overhead power lines have become a concern to the public due to its adverse health effects such as leukemia in children. A report from World Health Organization (WHO) stated that radiated magnetic fields from overhead power lines may cause leukemia in children if they are exposed to it every day. Therefore, the main objective of this study is to measure the magnetic field radiated from 132/275kV power lines. EMDEX II, a free body meter is used to measure the magnetic field at 1 meter above ground level and the lateral profile was proven using MATLAB calculation. The measurement was done at SJK (T) Gelang Patah and Taman Pulai Utama at a distance of 35 meter from the outermost conductor. The results from both locations show that the radiated magnetic field is much lower than the exposure limit stated in the ICNIRP standard, in which the highest data recorded is only 4mG. The lateral profile magnetic field also shows that exposure to magnetic fields directly below the overhead power line are within the ICNIRP recommended exposure limits. Thus, it can be concluded that the magnetic field radiated by 132/275kV power lines in Malaysia operate at a safe level. Penerbit UTM Press 2017 Article PeerReviewed Jimbin, V. S. and Ahmad, N. A. (2017) Magnetic field measurement from 132/275 KV overhead power lines. Jurnal Teknologi, 79 (1). pp. 89-95. ISSN 0127-9696 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85008165468&doi=10.11113%2fjt.v79.7270&partnerID=40&md5=2e1aa5bcc26516d5d544fa951a5a2ce2 DOI:10.11113/jt.v79.7270
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic T Technology (General)
spellingShingle T Technology (General)
Jimbin, V. S.
Ahmad, N. A.
Magnetic field measurement from 132/275 KV overhead power lines
description This paper presents a study on magnetic field radiated from 132/275kV overhead power lines. The magnetic field radiation from overhead power lines have become a concern to the public due to its adverse health effects such as leukemia in children. A report from World Health Organization (WHO) stated that radiated magnetic fields from overhead power lines may cause leukemia in children if they are exposed to it every day. Therefore, the main objective of this study is to measure the magnetic field radiated from 132/275kV power lines. EMDEX II, a free body meter is used to measure the magnetic field at 1 meter above ground level and the lateral profile was proven using MATLAB calculation. The measurement was done at SJK (T) Gelang Patah and Taman Pulai Utama at a distance of 35 meter from the outermost conductor. The results from both locations show that the radiated magnetic field is much lower than the exposure limit stated in the ICNIRP standard, in which the highest data recorded is only 4mG. The lateral profile magnetic field also shows that exposure to magnetic fields directly below the overhead power line are within the ICNIRP recommended exposure limits. Thus, it can be concluded that the magnetic field radiated by 132/275kV power lines in Malaysia operate at a safe level.
format Article
author Jimbin, V. S.
Ahmad, N. A.
author_facet Jimbin, V. S.
Ahmad, N. A.
author_sort Jimbin, V. S.
title Magnetic field measurement from 132/275 KV overhead power lines
title_short Magnetic field measurement from 132/275 KV overhead power lines
title_full Magnetic field measurement from 132/275 KV overhead power lines
title_fullStr Magnetic field measurement from 132/275 KV overhead power lines
title_full_unstemmed Magnetic field measurement from 132/275 KV overhead power lines
title_sort magnetic field measurement from 132/275 kv overhead power lines
publisher Penerbit UTM Press
publishDate 2017
url http://eprints.utm.my/id/eprint/76754/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85008165468&doi=10.11113%2fjt.v79.7270&partnerID=40&md5=2e1aa5bcc26516d5d544fa951a5a2ce2
_version_ 1643657400317640704