Investigation of torque generation capability of mixed flow turbine under steady state conditions

A mixed flow turbine is a type of turbine that is used mostly in turbocharger engine for vehicle. The ability of this turbine in obtain maximum efficiency on a wider operating range makes it more favorable compared to axial turbine and radial turbine. In this project, one of the factors affecting tu...

Full description

Saved in:
Bibliographic Details
Main Authors: Izaiddin, M. A. S., Mustaffa, A. F., Padzillah, M. H.
Format: Article
Published: Penerbit UTM Press 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/76735/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85035100789&doi=10.11113%2fjt.v79.11924&partnerID=40&md5=c4f6304018652d8176c687be81b11df7
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.76735
record_format eprints
spelling my.utm.767352018-04-30T13:56:08Z http://eprints.utm.my/id/eprint/76735/ Investigation of torque generation capability of mixed flow turbine under steady state conditions Izaiddin, M. A. S. Mustaffa, A. F. Padzillah, M. H. T Technology (General) A mixed flow turbine is a type of turbine that is used mostly in turbocharger engine for vehicle. The ability of this turbine in obtain maximum efficiency on a wider operating range makes it more favorable compared to axial turbine and radial turbine. In this project, one of the factors affecting turbine performance which is torque has been studied using simulation. The simulation is then being run by varying the mass flow supply to the turbine. In this simulation, torque generation has been identified and plot on the entire blade surface. This torque generation capability is then been compared between 0.25 kg/s, 0.45 kg/s and 0.65 kg/s mass flow. From the simulation, the torque generated is founded to fluctuate along the turbine blade surface. Besides, the torque generated at the leading edge and trailing edge surface are negative. The magnitude of torque generated increases, as the mass flow increased. At the mid span of the blade, torque generated at 0.25 kg/s, 0.45 kg/s and 0.65 kg/s is -3.73 × 10-3Nm, 4.33 × 10-3Nm, and 11.8 × 10-3Nm respectively. Penerbit UTM Press 2017 Article PeerReviewed Izaiddin, M. A. S. and Mustaffa, A. F. and Padzillah, M. H. (2017) Investigation of torque generation capability of mixed flow turbine under steady state conditions. Jurnal Teknologi, 79 (7-3). pp. 105-112. ISSN 0127-9696 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85035100789&doi=10.11113%2fjt.v79.11924&partnerID=40&md5=c4f6304018652d8176c687be81b11df7 DOI:10.11113/jt.v79.11924
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic T Technology (General)
spellingShingle T Technology (General)
Izaiddin, M. A. S.
Mustaffa, A. F.
Padzillah, M. H.
Investigation of torque generation capability of mixed flow turbine under steady state conditions
description A mixed flow turbine is a type of turbine that is used mostly in turbocharger engine for vehicle. The ability of this turbine in obtain maximum efficiency on a wider operating range makes it more favorable compared to axial turbine and radial turbine. In this project, one of the factors affecting turbine performance which is torque has been studied using simulation. The simulation is then being run by varying the mass flow supply to the turbine. In this simulation, torque generation has been identified and plot on the entire blade surface. This torque generation capability is then been compared between 0.25 kg/s, 0.45 kg/s and 0.65 kg/s mass flow. From the simulation, the torque generated is founded to fluctuate along the turbine blade surface. Besides, the torque generated at the leading edge and trailing edge surface are negative. The magnitude of torque generated increases, as the mass flow increased. At the mid span of the blade, torque generated at 0.25 kg/s, 0.45 kg/s and 0.65 kg/s is -3.73 × 10-3Nm, 4.33 × 10-3Nm, and 11.8 × 10-3Nm respectively.
format Article
author Izaiddin, M. A. S.
Mustaffa, A. F.
Padzillah, M. H.
author_facet Izaiddin, M. A. S.
Mustaffa, A. F.
Padzillah, M. H.
author_sort Izaiddin, M. A. S.
title Investigation of torque generation capability of mixed flow turbine under steady state conditions
title_short Investigation of torque generation capability of mixed flow turbine under steady state conditions
title_full Investigation of torque generation capability of mixed flow turbine under steady state conditions
title_fullStr Investigation of torque generation capability of mixed flow turbine under steady state conditions
title_full_unstemmed Investigation of torque generation capability of mixed flow turbine under steady state conditions
title_sort investigation of torque generation capability of mixed flow turbine under steady state conditions
publisher Penerbit UTM Press
publishDate 2017
url http://eprints.utm.my/id/eprint/76735/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85035100789&doi=10.11113%2fjt.v79.11924&partnerID=40&md5=c4f6304018652d8176c687be81b11df7
_version_ 1643657395293913088
score 13.18916