Assessment of atomization parameters for flat fan nozzles based on wind tunnel measurements

The main objective of this study involved testing of nozzle type, driving speed and wind speed effects on atomization parameters for broadcast spraying application. Two broadcast nozzle types flat fan extended range XR11003 and flat fan drift guard nozzle DG11003 were tested under wind tunnel condit...

Full description

Saved in:
Bibliographic Details
Main Authors: Hassen, N. S., Sidik, N. A. C.
Format: Article
Published: Penerbit Akademia Baru 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/76388/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85042744654&partnerID=40&md5=7f0e94e46b2373d5dd883309a3fa7c34
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.76388
record_format eprints
spelling my.utm.763882018-06-29T22:25:25Z http://eprints.utm.my/id/eprint/76388/ Assessment of atomization parameters for flat fan nozzles based on wind tunnel measurements Hassen, N. S. Sidik, N. A. C. TJ Mechanical engineering and machinery The main objective of this study involved testing of nozzle type, driving speed and wind speed effects on atomization parameters for broadcast spraying application. Two broadcast nozzle types flat fan extended range XR11003 and flat fan drift guard nozzle DG11003 were tested under wind tunnel conditions. To validate spraying results, the reference nozzle of spraying systems flat fan TeeJet nozzle TP11003 was used for comparison. The results of this study indicate an obvious effect of the technical variables and wind variable on atomization parameters. The nozzle DG11003 produced droplet size spectra of D0.1, D0.5 and D0.9 bigger than the extended range nozzle and reference nozzle. The droplet size spectra became smaller under increasing of the driving speed. Droplet size parameters generally tended to be coarser at the higher wind speeds. This study supports the use of nozzle DG11003 as a means for controlling spray distribution. Penerbit Akademia Baru 2017 Article PeerReviewed Hassen, N. S. and Sidik, N. A. C. (2017) Assessment of atomization parameters for flat fan nozzles based on wind tunnel measurements. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 38 (1). pp. 1-9. ISSN 2289-7879 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85042744654&partnerID=40&md5=7f0e94e46b2373d5dd883309a3fa7c34
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Hassen, N. S.
Sidik, N. A. C.
Assessment of atomization parameters for flat fan nozzles based on wind tunnel measurements
description The main objective of this study involved testing of nozzle type, driving speed and wind speed effects on atomization parameters for broadcast spraying application. Two broadcast nozzle types flat fan extended range XR11003 and flat fan drift guard nozzle DG11003 were tested under wind tunnel conditions. To validate spraying results, the reference nozzle of spraying systems flat fan TeeJet nozzle TP11003 was used for comparison. The results of this study indicate an obvious effect of the technical variables and wind variable on atomization parameters. The nozzle DG11003 produced droplet size spectra of D0.1, D0.5 and D0.9 bigger than the extended range nozzle and reference nozzle. The droplet size spectra became smaller under increasing of the driving speed. Droplet size parameters generally tended to be coarser at the higher wind speeds. This study supports the use of nozzle DG11003 as a means for controlling spray distribution.
format Article
author Hassen, N. S.
Sidik, N. A. C.
author_facet Hassen, N. S.
Sidik, N. A. C.
author_sort Hassen, N. S.
title Assessment of atomization parameters for flat fan nozzles based on wind tunnel measurements
title_short Assessment of atomization parameters for flat fan nozzles based on wind tunnel measurements
title_full Assessment of atomization parameters for flat fan nozzles based on wind tunnel measurements
title_fullStr Assessment of atomization parameters for flat fan nozzles based on wind tunnel measurements
title_full_unstemmed Assessment of atomization parameters for flat fan nozzles based on wind tunnel measurements
title_sort assessment of atomization parameters for flat fan nozzles based on wind tunnel measurements
publisher Penerbit Akademia Baru
publishDate 2017
url http://eprints.utm.my/id/eprint/76388/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85042744654&partnerID=40&md5=7f0e94e46b2373d5dd883309a3fa7c34
_version_ 1643657296690020352
score 13.18916