Charge-coupled device based on optical tomography system for monitoring two-phase flow
An application of charge-coupled device (CCD) linear sensor and laser diode in an optical tomography (OPT) system is presented. The measurements are based on the final light intensity received by the sensor. The aim is to analyse and demonstrate the capability of laser with a CCD in an OPT system fo...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Published: |
Institution of Engineering and Technology
2017
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/76110/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-85041485856&doi=10.1049%2fel.2016.3084&partnerID=40&md5=743506acd5d26c23db4420c2117dd99a |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.76110 |
---|---|
record_format |
eprints |
spelling |
my.utm.761102018-05-30T04:21:55Z http://eprints.utm.my/id/eprint/76110/ Charge-coupled device based on optical tomography system for monitoring two-phase flow Jamaludin, J. Rahim, R. A. Rahim, H. A. Rahiman, M. H. F. Rohani, J. M. TK Electrical engineering. Electronics Nuclear engineering An application of charge-coupled device (CCD) linear sensor and laser diode in an optical tomography (OPT) system is presented. The measurements are based on the final light intensity received by the sensor. The aim is to analyse and demonstrate the capability of laser with a CCD in an OPT system for detecting transparent objects in crystal clear water. The image reconstruction algorithms used were filtered images of linear back projection algorithms. These algorithms were programmed using LabVIEW programming software. Experiments in detecting transparent hollow straw were conducted. Based on the results, statistical analysis was performed to verify that the captured data were valid compared with the actual object data. The object's characteristics such as diameter also are observed. In conclusion, a non-intrusive and non-invasive OPT system that can detect transparent objects in crystal clear water is successfully developed. Institution of Engineering and Technology 2017 Article PeerReviewed Jamaludin, J. and Rahim, R. A. and Rahim, H. A. and Rahiman, M. H. F. and Rohani, J. M. (2017) Charge-coupled device based on optical tomography system for monitoring two-phase flow. Electronics Letters, 53 (5). pp. 331-333. ISSN 0013-5194 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85041485856&doi=10.1049%2fel.2016.3084&partnerID=40&md5=743506acd5d26c23db4420c2117dd99a |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Jamaludin, J. Rahim, R. A. Rahim, H. A. Rahiman, M. H. F. Rohani, J. M. Charge-coupled device based on optical tomography system for monitoring two-phase flow |
description |
An application of charge-coupled device (CCD) linear sensor and laser diode in an optical tomography (OPT) system is presented. The measurements are based on the final light intensity received by the sensor. The aim is to analyse and demonstrate the capability of laser with a CCD in an OPT system for detecting transparent objects in crystal clear water. The image reconstruction algorithms used were filtered images of linear back projection algorithms. These algorithms were programmed using LabVIEW programming software. Experiments in detecting transparent hollow straw were conducted. Based on the results, statistical analysis was performed to verify that the captured data were valid compared with the actual object data. The object's characteristics such as diameter also are observed. In conclusion, a non-intrusive and non-invasive OPT system that can detect transparent objects in crystal clear water is successfully developed. |
format |
Article |
author |
Jamaludin, J. Rahim, R. A. Rahim, H. A. Rahiman, M. H. F. Rohani, J. M. |
author_facet |
Jamaludin, J. Rahim, R. A. Rahim, H. A. Rahiman, M. H. F. Rohani, J. M. |
author_sort |
Jamaludin, J. |
title |
Charge-coupled device based on optical tomography system for monitoring two-phase flow |
title_short |
Charge-coupled device based on optical tomography system for monitoring two-phase flow |
title_full |
Charge-coupled device based on optical tomography system for monitoring two-phase flow |
title_fullStr |
Charge-coupled device based on optical tomography system for monitoring two-phase flow |
title_full_unstemmed |
Charge-coupled device based on optical tomography system for monitoring two-phase flow |
title_sort |
charge-coupled device based on optical tomography system for monitoring two-phase flow |
publisher |
Institution of Engineering and Technology |
publishDate |
2017 |
url |
http://eprints.utm.my/id/eprint/76110/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-85041485856&doi=10.1049%2fel.2016.3084&partnerID=40&md5=743506acd5d26c23db4420c2117dd99a |
_version_ |
1643657220422893568 |
score |
13.209306 |