The Effect of PCA-g-MWCNTs loading on the performance of PES/MWCNTs hemodialysis membrane

Membrane fouling is one of the biggest obstacles towards hemodialysis treatment. In this work, multi-walled carbon nanotubes (MWCNTs) are incorporated to enhance the hydrophilicity and antifouling property of polyethersulfone (PES) hemodialysis membrane. Prior to the mixing, surface functionalisatio...

Full description

Saved in:
Bibliographic Details
Main Authors: Abidin, M. N. Z., Goh, P. S., Ismail, A. F., Othman, M. H. D., Hasbullah, H., Said, N., Kadir, S. H. S. A., Kamal, F., Abdullah, M. S., Ng, B. C.
Format: Article
Published: Italian Association of Chemical Engineering - AIDIC 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/75841/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85019430043&doi=10.3303%2fCET1756269&partnerID=40&md5=544dc50b53b8f8a5883009ece0a568e7
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.75841
record_format eprints
spelling my.utm.758412018-05-30T04:01:43Z http://eprints.utm.my/id/eprint/75841/ The Effect of PCA-g-MWCNTs loading on the performance of PES/MWCNTs hemodialysis membrane Abidin, M. N. Z. Goh, P. S. Ismail, A. F. Othman, M. H. D. Hasbullah, H. Said, N. Kadir, S. H. S. A. Kamal, F. Abdullah, M. S. Ng, B. C. TP Chemical technology Membrane fouling is one of the biggest obstacles towards hemodialysis treatment. In this work, multi-walled carbon nanotubes (MWCNTs) are incorporated to enhance the hydrophilicity and antifouling property of polyethersulfone (PES) hemodialysis membrane. Prior to the mixing, surface functionalisation of MWCNTs was carried out to introduce a large hyperbranched poly (citric acid) (PCA) for better dispersion. PCA-grafted (g)- MWCNTs were prepared by grafting citric acid monohydrate onto the wall of purified MWCNTs. PCA-g- MWCNTs (0 - 0.2 wt%) were then dispersed in PES and polyvinylpyrrolidone blends. The membranes were spun at 50 cm air gap, characterised in terms of morphology and hydrophilic properties before tested for pure water flux (PWF) and protein rejection using bovine serum albumin (BSA). The results revealed that, compared to the neat PES membrane, the PES/MWCNTs membranes were more hydrophilic. The highest PWF (110.4 L m-2 h-1) was achieved by the membrane incorporated with 0.1 wt% PCA-g-MWCNTs. Same trend was observed for protein rejection, where up to 0.1 wt% loading of PCA-g-MWCNTs, the PES/MWCNTs membrane rejected 97.3 % of BSA compared to 88.2 % as obtained from the neat membrane. It was found that the PES/MWCNTs membranes possessed a greater PWF recovery ratio, proving that the membranes antifouling property was improved. The addition of PCA-g-MWCNTs in the membranes enhanced the hydrophilicity as well as the antifouling property of the PES membrane for hemodialysis application. Italian Association of Chemical Engineering - AIDIC 2017 Article PeerReviewed Abidin, M. N. Z. and Goh, P. S. and Ismail, A. F. and Othman, M. H. D. and Hasbullah, H. and Said, N. and Kadir, S. H. S. A. and Kamal, F. and Abdullah, M. S. and Ng, B. C. (2017) The Effect of PCA-g-MWCNTs loading on the performance of PES/MWCNTs hemodialysis membrane. Chemical Engineering Transactions, 56 . pp. 1609-1614. ISSN 2283-9216 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85019430043&doi=10.3303%2fCET1756269&partnerID=40&md5=544dc50b53b8f8a5883009ece0a568e7
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TP Chemical technology
spellingShingle TP Chemical technology
Abidin, M. N. Z.
Goh, P. S.
Ismail, A. F.
Othman, M. H. D.
Hasbullah, H.
Said, N.
Kadir, S. H. S. A.
Kamal, F.
Abdullah, M. S.
Ng, B. C.
The Effect of PCA-g-MWCNTs loading on the performance of PES/MWCNTs hemodialysis membrane
description Membrane fouling is one of the biggest obstacles towards hemodialysis treatment. In this work, multi-walled carbon nanotubes (MWCNTs) are incorporated to enhance the hydrophilicity and antifouling property of polyethersulfone (PES) hemodialysis membrane. Prior to the mixing, surface functionalisation of MWCNTs was carried out to introduce a large hyperbranched poly (citric acid) (PCA) for better dispersion. PCA-grafted (g)- MWCNTs were prepared by grafting citric acid monohydrate onto the wall of purified MWCNTs. PCA-g- MWCNTs (0 - 0.2 wt%) were then dispersed in PES and polyvinylpyrrolidone blends. The membranes were spun at 50 cm air gap, characterised in terms of morphology and hydrophilic properties before tested for pure water flux (PWF) and protein rejection using bovine serum albumin (BSA). The results revealed that, compared to the neat PES membrane, the PES/MWCNTs membranes were more hydrophilic. The highest PWF (110.4 L m-2 h-1) was achieved by the membrane incorporated with 0.1 wt% PCA-g-MWCNTs. Same trend was observed for protein rejection, where up to 0.1 wt% loading of PCA-g-MWCNTs, the PES/MWCNTs membrane rejected 97.3 % of BSA compared to 88.2 % as obtained from the neat membrane. It was found that the PES/MWCNTs membranes possessed a greater PWF recovery ratio, proving that the membranes antifouling property was improved. The addition of PCA-g-MWCNTs in the membranes enhanced the hydrophilicity as well as the antifouling property of the PES membrane for hemodialysis application.
format Article
author Abidin, M. N. Z.
Goh, P. S.
Ismail, A. F.
Othman, M. H. D.
Hasbullah, H.
Said, N.
Kadir, S. H. S. A.
Kamal, F.
Abdullah, M. S.
Ng, B. C.
author_facet Abidin, M. N. Z.
Goh, P. S.
Ismail, A. F.
Othman, M. H. D.
Hasbullah, H.
Said, N.
Kadir, S. H. S. A.
Kamal, F.
Abdullah, M. S.
Ng, B. C.
author_sort Abidin, M. N. Z.
title The Effect of PCA-g-MWCNTs loading on the performance of PES/MWCNTs hemodialysis membrane
title_short The Effect of PCA-g-MWCNTs loading on the performance of PES/MWCNTs hemodialysis membrane
title_full The Effect of PCA-g-MWCNTs loading on the performance of PES/MWCNTs hemodialysis membrane
title_fullStr The Effect of PCA-g-MWCNTs loading on the performance of PES/MWCNTs hemodialysis membrane
title_full_unstemmed The Effect of PCA-g-MWCNTs loading on the performance of PES/MWCNTs hemodialysis membrane
title_sort effect of pca-g-mwcnts loading on the performance of pes/mwcnts hemodialysis membrane
publisher Italian Association of Chemical Engineering - AIDIC
publishDate 2017
url http://eprints.utm.my/id/eprint/75841/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85019430043&doi=10.3303%2fCET1756269&partnerID=40&md5=544dc50b53b8f8a5883009ece0a568e7
_version_ 1643657174372581376
score 13.160551