Harmful gases profiling in Meru Menora Tunnel using SICK sensor

This paper discusses the study on the measured harmful gases due to traffic emission in the Meru Menora Tunnel, a Malaysia highway tunnel. The hazardous gasses data would help in promoting essential ventilation system inside the tunnel for the health and safety of the users. The emission gasses conc...

Full description

Saved in:
Bibliographic Details
Main Authors: Baharun, A. N., Murad, N. A., Malik, N. N. N. A.
Format: Article
Language:English
Published: Universitas Ahmad Dahlan 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/75637/1/NAMurad_HarmfulGasesProfilinginMeruMenora.pdf
http://eprints.utm.my/id/eprint/75637/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85020209509&doi=10.12928%2fTELKOMNIKA.v15i2.6141&partnerID=40&md5=ef4b0e1121fbf1d04c7e1af782a80386
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.75637
record_format eprints
spelling my.utm.756372018-04-27T01:39:17Z http://eprints.utm.my/id/eprint/75637/ Harmful gases profiling in Meru Menora Tunnel using SICK sensor Baharun, A. N. Murad, N. A. Malik, N. N. N. A. TK Electrical engineering. Electronics Nuclear engineering This paper discusses the study on the measured harmful gases due to traffic emission in the Meru Menora Tunnel, a Malaysia highway tunnel. The hazardous gasses data would help in promoting essential ventilation system inside the tunnel for the health and safety of the users. The emission gasses concentration reading is divided into two main components comprise of Nitrogen Dioxide (NO2), and Carbon Monoxide (CO). Other than that, the visibility also been measured by using SICK sensor. The measurement has been done during normal, festive and school holiday seasons. Festive season shows the highest number of traffic and thus giving the worst air quality. Ventilation fan system can be activated based on the concentration level of gases and visibility in the tunnel. Universitas Ahmad Dahlan 2017 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/75637/1/NAMurad_HarmfulGasesProfilinginMeruMenora.pdf Baharun, A. N. and Murad, N. A. and Malik, N. N. N. A. (2017) Harmful gases profiling in Meru Menora Tunnel using SICK sensor. Telkomnika (Telecommunication Computing Electronics and Control), 15 (2). pp. 888-894. ISSN 1693-6930 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85020209509&doi=10.12928%2fTELKOMNIKA.v15i2.6141&partnerID=40&md5=ef4b0e1121fbf1d04c7e1af782a80386
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Baharun, A. N.
Murad, N. A.
Malik, N. N. N. A.
Harmful gases profiling in Meru Menora Tunnel using SICK sensor
description This paper discusses the study on the measured harmful gases due to traffic emission in the Meru Menora Tunnel, a Malaysia highway tunnel. The hazardous gasses data would help in promoting essential ventilation system inside the tunnel for the health and safety of the users. The emission gasses concentration reading is divided into two main components comprise of Nitrogen Dioxide (NO2), and Carbon Monoxide (CO). Other than that, the visibility also been measured by using SICK sensor. The measurement has been done during normal, festive and school holiday seasons. Festive season shows the highest number of traffic and thus giving the worst air quality. Ventilation fan system can be activated based on the concentration level of gases and visibility in the tunnel.
format Article
author Baharun, A. N.
Murad, N. A.
Malik, N. N. N. A.
author_facet Baharun, A. N.
Murad, N. A.
Malik, N. N. N. A.
author_sort Baharun, A. N.
title Harmful gases profiling in Meru Menora Tunnel using SICK sensor
title_short Harmful gases profiling in Meru Menora Tunnel using SICK sensor
title_full Harmful gases profiling in Meru Menora Tunnel using SICK sensor
title_fullStr Harmful gases profiling in Meru Menora Tunnel using SICK sensor
title_full_unstemmed Harmful gases profiling in Meru Menora Tunnel using SICK sensor
title_sort harmful gases profiling in meru menora tunnel using sick sensor
publisher Universitas Ahmad Dahlan