Image reconstruction for solid profile measurement in ERT using non-invasive approach

Image reconstruction software and its image reconstruction algorithm are an important step towards constructing a tomography system. This paper demonstrates an image reconstruction of solid profile using linear back projection (LBP) algorithm and global threshold. A forward problem and inverse probl...

Full description

Saved in:
Bibliographic Details
Main Authors: Wahab, Y. A., Rahim, R. A., Rahiman, M. H. F., Ling, L. P., Aw, S. R., Pusppanathan, M. J., Abd. Shaib, M. F., Rahim, H. A., Mohamad, E. J.
Format: Article
Language:English
Published: Universitas Ahmad Dahlan 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/75627/1/RuzairiAbdulRahim_ImageReconstructionforSolidProfileMeasurement.pdf
http://eprints.utm.my/id/eprint/75627/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85040602777&doi=10.12928%2fTELKOMNIKA.v15i4.7234&partnerID=40&md5=f5dfdf1e1f58f1428fa86d104be2c248
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.75627
record_format eprints
spelling my.utm.756272018-04-27T01:37:25Z http://eprints.utm.my/id/eprint/75627/ Image reconstruction for solid profile measurement in ERT using non-invasive approach Wahab, Y. A. Rahim, R. A. Rahiman, M. H. F. Ling, L. P. Aw, S. R. Pusppanathan, M. J. Abd. Shaib, M. F. Rahim, H. A. Mohamad, E. J. TK Electrical engineering. Electronics Nuclear engineering Image reconstruction software and its image reconstruction algorithm are an important step towards constructing a tomography system. This paper demonstrates an image reconstruction of solid profile using linear back projection (LBP) algorithm and global threshold. A forward problem and inverse problem are discussed. The modelled of sensitivity distributions using COMSOL proved that the system is able to detect the liquid-solid regime in vertical pipe. Additionally, the location of the phantom can be easily distinguished using LBP algorithm and thresholding technique. The simulations and experiments results indicate that the sensitivity distribution of non-invasive ERT system can be applied in getting a tomogram of the medium of interest. Universitas Ahmad Dahlan 2017 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/75627/1/RuzairiAbdulRahim_ImageReconstructionforSolidProfileMeasurement.pdf Wahab, Y. A. and Rahim, R. A. and Rahiman, M. H. F. and Ling, L. P. and Aw, S. R. and Pusppanathan, M. J. and Abd. Shaib, M. F. and Rahim, H. A. and Mohamad, E. J. (2017) Image reconstruction for solid profile measurement in ERT using non-invasive approach. Telkomnika (Telecommunication Computing Electronics and Control), 15 (4). pp. 1554-1564. ISSN 1693-6930 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85040602777&doi=10.12928%2fTELKOMNIKA.v15i4.7234&partnerID=40&md5=f5dfdf1e1f58f1428fa86d104be2c248
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Wahab, Y. A.
Rahim, R. A.
Rahiman, M. H. F.
Ling, L. P.
Aw, S. R.
Pusppanathan, M. J.
Abd. Shaib, M. F.
Rahim, H. A.
Mohamad, E. J.
Image reconstruction for solid profile measurement in ERT using non-invasive approach
description Image reconstruction software and its image reconstruction algorithm are an important step towards constructing a tomography system. This paper demonstrates an image reconstruction of solid profile using linear back projection (LBP) algorithm and global threshold. A forward problem and inverse problem are discussed. The modelled of sensitivity distributions using COMSOL proved that the system is able to detect the liquid-solid regime in vertical pipe. Additionally, the location of the phantom can be easily distinguished using LBP algorithm and thresholding technique. The simulations and experiments results indicate that the sensitivity distribution of non-invasive ERT system can be applied in getting a tomogram of the medium of interest.
format Article
author Wahab, Y. A.
Rahim, R. A.
Rahiman, M. H. F.
Ling, L. P.
Aw, S. R.
Pusppanathan, M. J.
Abd. Shaib, M. F.
Rahim, H. A.
Mohamad, E. J.
author_facet Wahab, Y. A.
Rahim, R. A.
Rahiman, M. H. F.
Ling, L. P.
Aw, S. R.
Pusppanathan, M. J.
Abd. Shaib, M. F.
Rahim, H. A.
Mohamad, E. J.
author_sort Wahab, Y. A.
title Image reconstruction for solid profile measurement in ERT using non-invasive approach
title_short Image reconstruction for solid profile measurement in ERT using non-invasive approach
title_full Image reconstruction for solid profile measurement in ERT using non-invasive approach
title_fullStr Image reconstruction for solid profile measurement in ERT using non-invasive approach
title_full_unstemmed Image reconstruction for solid profile measurement in ERT using non-invasive approach
title_sort image reconstruction for solid profile measurement in ert using non-invasive approach
publisher Universitas Ahmad Dahlan
publishDate 2017
url http://eprints.utm.my/id/eprint/75627/1/RuzairiAbdulRahim_ImageReconstructionforSolidProfileMeasurement.pdf
http://eprints.utm.my/id/eprint/75627/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85040602777&doi=10.12928%2fTELKOMNIKA.v15i4.7234&partnerID=40&md5=f5dfdf1e1f58f1428fa86d104be2c248
_version_ 1643657115850506240
score 13.160551