Calibration of ZMPT101B voltage sensor module using polynomial regression for accurate load monitoring

Smart Electricity is quickly developing as the results of advancements in sensor technology. The accuracy of a sensing device is the backbone of every measurement and the fundamental of every electrical quantity measurement is the voltage and current sensing. The sensor calibration in the context of...

Full description

Saved in:
Bibliographic Details
Main Authors: Abubakar, I., Khalid, S. N., Mustafa, M. W., Shareef, H., Mustapha, M.
Format: Article
Language:English
Published: Asian Research Publishing Network 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/75404/1/Abubakar_CalibrationofZMPT101BVoltageSensor.pdf
http://eprints.utm.my/id/eprint/75404/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85014112724&partnerID=40&md5=2a06631b15fccf6e038bb0b83ef9b0f8
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.75404
record_format eprints
spelling my.utm.754042018-03-22T11:07:35Z http://eprints.utm.my/id/eprint/75404/ Calibration of ZMPT101B voltage sensor module using polynomial regression for accurate load monitoring Abubakar, I. Khalid, S. N. Mustafa, M. W. Shareef, H. Mustapha, M. TK Electrical engineering. Electronics Nuclear engineering Smart Electricity is quickly developing as the results of advancements in sensor technology. The accuracy of a sensing device is the backbone of every measurement and the fundamental of every electrical quantity measurement is the voltage and current sensing. The sensor calibration in the context of this research means the marking or scaling of the voltage sensor so that it can present accurate sampled voltage from the ADC output using appropriate algorithm. The peakpeak input voltage (measured with a standard FLUKE 115 meter) to the sensor is correlated with the peak-peak ADC output of the sensor using 1 to 5th order polynomial regression, in order to determine the best fitting relationship between them. The arduino microcontroller is used to receive the ADC conversion and is also programmed to calculate the root mean square value of the supply voltage. The analysis of the polynomials shows that the third order polynomial gives the best relationship between the analog input and ADC output. The accuracy of the algorithm is tested in measuring the root mean square values of the supply voltage using instantaneous voltage calculation and peak-peak voltage methods. The error in the measurement is less than 1% in the peak-peak method and less than 2.5% in the instantaneous method for voltage measurements above 50V AC, which is very good for measurements in utility. Therefore, the proposed calibration method will facilitate more accurate voltage and power computing for researchers and designers especially in load monitoring where the applied voltage is 240V or 120V ranges. Asian Research Publishing Network 2017 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/75404/1/Abubakar_CalibrationofZMPT101BVoltageSensor.pdf Abubakar, I. and Khalid, S. N. and Mustafa, M. W. and Shareef, H. and Mustapha, M. (2017) Calibration of ZMPT101B voltage sensor module using polynomial regression for accurate load monitoring. ARPN Journal of Engineering and Applied Sciences, 12 (4). pp. 1076-1084. ISSN 1819-6608 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85014112724&partnerID=40&md5=2a06631b15fccf6e038bb0b83ef9b0f8
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Abubakar, I.
Khalid, S. N.
Mustafa, M. W.
Shareef, H.
Mustapha, M.
Calibration of ZMPT101B voltage sensor module using polynomial regression for accurate load monitoring
description Smart Electricity is quickly developing as the results of advancements in sensor technology. The accuracy of a sensing device is the backbone of every measurement and the fundamental of every electrical quantity measurement is the voltage and current sensing. The sensor calibration in the context of this research means the marking or scaling of the voltage sensor so that it can present accurate sampled voltage from the ADC output using appropriate algorithm. The peakpeak input voltage (measured with a standard FLUKE 115 meter) to the sensor is correlated with the peak-peak ADC output of the sensor using 1 to 5th order polynomial regression, in order to determine the best fitting relationship between them. The arduino microcontroller is used to receive the ADC conversion and is also programmed to calculate the root mean square value of the supply voltage. The analysis of the polynomials shows that the third order polynomial gives the best relationship between the analog input and ADC output. The accuracy of the algorithm is tested in measuring the root mean square values of the supply voltage using instantaneous voltage calculation and peak-peak voltage methods. The error in the measurement is less than 1% in the peak-peak method and less than 2.5% in the instantaneous method for voltage measurements above 50V AC, which is very good for measurements in utility. Therefore, the proposed calibration method will facilitate more accurate voltage and power computing for researchers and designers especially in load monitoring where the applied voltage is 240V or 120V ranges.
format Article
author Abubakar, I.
Khalid, S. N.
Mustafa, M. W.
Shareef, H.
Mustapha, M.
author_facet Abubakar, I.
Khalid, S. N.
Mustafa, M. W.
Shareef, H.
Mustapha, M.
author_sort Abubakar, I.
title Calibration of ZMPT101B voltage sensor module using polynomial regression for accurate load monitoring
title_short Calibration of ZMPT101B voltage sensor module using polynomial regression for accurate load monitoring
title_full Calibration of ZMPT101B voltage sensor module using polynomial regression for accurate load monitoring
title_fullStr Calibration of ZMPT101B voltage sensor module using polynomial regression for accurate load monitoring
title_full_unstemmed Calibration of ZMPT101B voltage sensor module using polynomial regression for accurate load monitoring
title_sort calibration of zmpt101b voltage sensor module using polynomial regression for accurate load monitoring
publisher Asian Research Publishing Network
publishDate 2017
url http://eprints.utm.my/id/eprint/75404/1/Abubakar_CalibrationofZMPT101BVoltageSensor.pdf
http://eprints.utm.my/id/eprint/75404/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85014112724&partnerID=40&md5=2a06631b15fccf6e038bb0b83ef9b0f8
_version_ 1643657054370398208
score 13.160551