Finite element analysis of the wrist arthroplasty in rheumatoid arthritis

This chapter presents information on finite element analyses (FEA) of stress distribution and contact pressure with the carpal articulation following total wrist arthroplasty (TWA) for rheumatoid arthritis (RA) of the wrist. Results from the previous analyses on the healthy and rheumatic wrist were...

Full description

Saved in:
Bibliographic Details
Main Authors: Bajuri, M. N., Abdul Kadir, M. R.
Format: Book Section
Published: Springer Verlag 2013
Subjects:
Online Access:http://eprints.utm.my/id/eprint/74662/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85028845685&doi=10.1007%2f978-3-642-31906-8_6&partnerID=40&md5=65bd7fef6ae5c9e9d73f641b25de5243
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.74662
record_format eprints
spelling my.utm.746622017-11-23T04:10:03Z http://eprints.utm.my/id/eprint/74662/ Finite element analysis of the wrist arthroplasty in rheumatoid arthritis Bajuri, M. N. Abdul Kadir, M. R. QH301 Biology This chapter presents information on finite element analyses (FEA) of stress distribution and contact pressure with the carpal articulation following total wrist arthroplasty (TWA) for rheumatoid arthritis (RA) of the wrist. Results from the previous analyses on the healthy and rheumatic wrist were used for comparison. A TWA model was developed based on parameters of a wrist implant named ReMotion™ total wrist system, and was then applied with the same boundary condition (static hand grip action) as the other two models. FEA has revealed that the contact pressure for the TWA model was five times lower than the RA model. Despite this encouraging finding, small variations in the amount of stress distribution were still present when compared to the healthy model. This comes to a conclusion that the used of TWA could reduces the high contact pressure induced in the RA model thus improving the diseased condition, however, there are rooms for improvement for TWA procedure to restore the biomechanical behaviour of the healthy wrist joint. Springer Verlag 2013 Book Section PeerReviewed Bajuri, M. N. and Abdul Kadir, M. R. (2013) Finite element analysis of the wrist arthroplasty in rheumatoid arthritis. In: SpringerBriefs in Applied Sciences and Technology. Springer Verlag, pp. 59-69. ISBN 978-364231905-1 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85028845685&doi=10.1007%2f978-3-642-31906-8_6&partnerID=40&md5=65bd7fef6ae5c9e9d73f641b25de5243
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic QH301 Biology
spellingShingle QH301 Biology
Bajuri, M. N.
Abdul Kadir, M. R.
Finite element analysis of the wrist arthroplasty in rheumatoid arthritis
description This chapter presents information on finite element analyses (FEA) of stress distribution and contact pressure with the carpal articulation following total wrist arthroplasty (TWA) for rheumatoid arthritis (RA) of the wrist. Results from the previous analyses on the healthy and rheumatic wrist were used for comparison. A TWA model was developed based on parameters of a wrist implant named ReMotion™ total wrist system, and was then applied with the same boundary condition (static hand grip action) as the other two models. FEA has revealed that the contact pressure for the TWA model was five times lower than the RA model. Despite this encouraging finding, small variations in the amount of stress distribution were still present when compared to the healthy model. This comes to a conclusion that the used of TWA could reduces the high contact pressure induced in the RA model thus improving the diseased condition, however, there are rooms for improvement for TWA procedure to restore the biomechanical behaviour of the healthy wrist joint.
format Book Section
author Bajuri, M. N.
Abdul Kadir, M. R.
author_facet Bajuri, M. N.
Abdul Kadir, M. R.
author_sort Bajuri, M. N.
title Finite element analysis of the wrist arthroplasty in rheumatoid arthritis
title_short Finite element analysis of the wrist arthroplasty in rheumatoid arthritis
title_full Finite element analysis of the wrist arthroplasty in rheumatoid arthritis
title_fullStr Finite element analysis of the wrist arthroplasty in rheumatoid arthritis
title_full_unstemmed Finite element analysis of the wrist arthroplasty in rheumatoid arthritis
title_sort finite element analysis of the wrist arthroplasty in rheumatoid arthritis
publisher Springer Verlag
publishDate 2013
url http://eprints.utm.my/id/eprint/74662/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85028845685&doi=10.1007%2f978-3-642-31906-8_6&partnerID=40&md5=65bd7fef6ae5c9e9d73f641b25de5243
_version_ 1643656903186710528