Rock bearing resistance of bored piles socketed into rock

In view of the large movement required to mobilise the base resistance of bored piles and difficulty in base cleaning, the end bearing resistance often ignored in current design practice that will result in excessive rock socket length. Many attempts have been made to correlate the end bearing resis...

Full description

Saved in:
Bibliographic Details
Main Authors: Sharudin, E. S., Mohd. Yunus, N. Z., Marto, A., Jusoh, S. N., Ahmad, K., Kasim, F., Abdullah, R. A., Hezmi, M. A.
Format: Article
Language:English
Published: Penerbit UTM Press 2016
Subjects:
Online Access:http://eprints.utm.my/id/eprint/74496/1/KamarudinAhmad2017_RockBearingResistanceofBoredPiles.pdf
http://eprints.utm.my/id/eprint/74496/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84988432905&doi=10.11113%2fjt.v78.9638&partnerID=40&md5=0a6ca6e3823ddb09f18b8ce835002f78
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.74496
record_format eprints
spelling my.utm.744962017-11-23T01:37:10Z http://eprints.utm.my/id/eprint/74496/ Rock bearing resistance of bored piles socketed into rock Sharudin, E. S. Mohd. Yunus, N. Z. Marto, A. Jusoh, S. N. Ahmad, K. Kasim, F. Abdullah, R. A. Hezmi, M. A. TA Engineering (General). Civil engineering (General) In view of the large movement required to mobilise the base resistance of bored piles and difficulty in base cleaning, the end bearing resistance often ignored in current design practice that will result in excessive rock socket length. Many attempts have been made to correlate the end bearing resistance with the uniaxial compressive strength of intact rock and the RQD but it is uncertain how applicable they are to rock type in Malaysia. This paper attempts to review the applicability of the formulas from previous studies to rock type in Malaysia. A program of field tests for 13 bored piles with diameter varying from 1000 mm to 1500 mm constructed in granite was conducted to measure the axial response of bored piles, tested using static load test and high strain load dynamic test to verify its integrity and performance. The results were evaluated and compared to the predicted rock bearing resistance. Based on the result obtained, the method by AASHTO gives the best prediction of rock bearing resistance for granite in Malaysia. However the relationship between compressive strength and rock discontinuities with the rock bearing resistance showed scattered results. Penerbit UTM Press 2016 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/74496/1/KamarudinAhmad2017_RockBearingResistanceofBoredPiles.pdf Sharudin, E. S. and Mohd. Yunus, N. Z. and Marto, A. and Jusoh, S. N. and Ahmad, K. and Kasim, F. and Abdullah, R. A. and Hezmi, M. A. (2016) Rock bearing resistance of bored piles socketed into rock. Jurnal Teknologi, 78 (8-6). pp. 45-51. ISSN 0127-9696 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84988432905&doi=10.11113%2fjt.v78.9638&partnerID=40&md5=0a6ca6e3823ddb09f18b8ce835002f78
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Sharudin, E. S.
Mohd. Yunus, N. Z.
Marto, A.
Jusoh, S. N.
Ahmad, K.
Kasim, F.
Abdullah, R. A.
Hezmi, M. A.
Rock bearing resistance of bored piles socketed into rock
description In view of the large movement required to mobilise the base resistance of bored piles and difficulty in base cleaning, the end bearing resistance often ignored in current design practice that will result in excessive rock socket length. Many attempts have been made to correlate the end bearing resistance with the uniaxial compressive strength of intact rock and the RQD but it is uncertain how applicable they are to rock type in Malaysia. This paper attempts to review the applicability of the formulas from previous studies to rock type in Malaysia. A program of field tests for 13 bored piles with diameter varying from 1000 mm to 1500 mm constructed in granite was conducted to measure the axial response of bored piles, tested using static load test and high strain load dynamic test to verify its integrity and performance. The results were evaluated and compared to the predicted rock bearing resistance. Based on the result obtained, the method by AASHTO gives the best prediction of rock bearing resistance for granite in Malaysia. However the relationship between compressive strength and rock discontinuities with the rock bearing resistance showed scattered results.
format Article
author Sharudin, E. S.
Mohd. Yunus, N. Z.
Marto, A.
Jusoh, S. N.
Ahmad, K.
Kasim, F.
Abdullah, R. A.
Hezmi, M. A.
author_facet Sharudin, E. S.
Mohd. Yunus, N. Z.
Marto, A.
Jusoh, S. N.
Ahmad, K.
Kasim, F.
Abdullah, R. A.
Hezmi, M. A.
author_sort Sharudin, E. S.
title Rock bearing resistance of bored piles socketed into rock
title_short Rock bearing resistance of bored piles socketed into rock
title_full Rock bearing resistance of bored piles socketed into rock
title_fullStr Rock bearing resistance of bored piles socketed into rock
title_full_unstemmed Rock bearing resistance of bored piles socketed into rock
title_sort rock bearing resistance of bored piles socketed into rock
publisher Penerbit UTM Press
publishDate 2016
url http://eprints.utm.my/id/eprint/74496/1/KamarudinAhmad2017_RockBearingResistanceofBoredPiles.pdf
http://eprints.utm.my/id/eprint/74496/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84988432905&doi=10.11113%2fjt.v78.9638&partnerID=40&md5=0a6ca6e3823ddb09f18b8ce835002f78
_version_ 1643656867011887104
score 13.160551