Statistical analysis of electric field parameters for negative lightning in Malaysia

This paper presents a comparative study on the electric field and its derivative parameters of negative lightning in Malaysia and other regions. This study is the first in Malaysia where the parameters of negative electric field and its derivative are thoroughly analyzed. 104 negative lightning flas...

Full description

Saved in:
Bibliographic Details
Main Authors: Wooi, C. L., Abdul Malek, Z., Ahmad, N. A., El Gayar, A. I.
Format: Article
Published: Elsevier Ltd 2016
Subjects:
Online Access:http://eprints.utm.my/id/eprint/74476/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84979300121&doi=10.1016%2fj.jastp.2016.05.007&partnerID=40&md5=5cc3e4eda247d6b647453da3f6cfdb37
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.74476
record_format eprints
spelling my.utm.744762017-11-29T23:58:44Z http://eprints.utm.my/id/eprint/74476/ Statistical analysis of electric field parameters for negative lightning in Malaysia Wooi, C. L. Abdul Malek, Z. Ahmad, N. A. El Gayar, A. I. TK Electrical engineering. Electronics Nuclear engineering This paper presents a comparative study on the electric field and its derivative parameters of negative lightning in Malaysia and other regions. This study is the first in Malaysia where the parameters of negative electric field and its derivative are thoroughly analyzed. 104 negative lightning flashes containing 277 negative return strokes occurring within 10–100 km from the measuring station and recorded during monsoon period in the state of Johor, Malaysia had been analyzed. It was found that 73% of the recorded flashes are multiple strokes with an average multiplicity of 2.6 strokes per flash. For first return strokes, the arithmetic mean (AM) of initial peak electric field and the AM of initial peak electric field derivative are 21.8 V/m and 11.3 V/m/µs, respectively. The initial peaks of electric field and its derivative for first return strokes are larger than those for the subsequent return strokes. Comparison of overall results with those obtained earlier in Sri Lanka, Germany, Sweden, Japan, Florida indicates that several electric field and its derivative parameters are affected by propagation media and geographical region. Similarity of results with other countries having the same climatic condition is also observed. Elsevier Ltd 2016 Article PeerReviewed Wooi, C. L. and Abdul Malek, Z. and Ahmad, N. A. and El Gayar, A. I. (2016) Statistical analysis of electric field parameters for negative lightning in Malaysia. Journal of Atmospheric and Solar-Terrestrial Physics, 146 . pp. 69-80. ISSN 1364-6826 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84979300121&doi=10.1016%2fj.jastp.2016.05.007&partnerID=40&md5=5cc3e4eda247d6b647453da3f6cfdb37
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Wooi, C. L.
Abdul Malek, Z.
Ahmad, N. A.
El Gayar, A. I.
Statistical analysis of electric field parameters for negative lightning in Malaysia
description This paper presents a comparative study on the electric field and its derivative parameters of negative lightning in Malaysia and other regions. This study is the first in Malaysia where the parameters of negative electric field and its derivative are thoroughly analyzed. 104 negative lightning flashes containing 277 negative return strokes occurring within 10–100 km from the measuring station and recorded during monsoon period in the state of Johor, Malaysia had been analyzed. It was found that 73% of the recorded flashes are multiple strokes with an average multiplicity of 2.6 strokes per flash. For first return strokes, the arithmetic mean (AM) of initial peak electric field and the AM of initial peak electric field derivative are 21.8 V/m and 11.3 V/m/µs, respectively. The initial peaks of electric field and its derivative for first return strokes are larger than those for the subsequent return strokes. Comparison of overall results with those obtained earlier in Sri Lanka, Germany, Sweden, Japan, Florida indicates that several electric field and its derivative parameters are affected by propagation media and geographical region. Similarity of results with other countries having the same climatic condition is also observed.
format Article
author Wooi, C. L.
Abdul Malek, Z.
Ahmad, N. A.
El Gayar, A. I.
author_facet Wooi, C. L.
Abdul Malek, Z.
Ahmad, N. A.
El Gayar, A. I.
author_sort Wooi, C. L.
title Statistical analysis of electric field parameters for negative lightning in Malaysia
title_short Statistical analysis of electric field parameters for negative lightning in Malaysia
title_full Statistical analysis of electric field parameters for negative lightning in Malaysia
title_fullStr Statistical analysis of electric field parameters for negative lightning in Malaysia
title_full_unstemmed Statistical analysis of electric field parameters for negative lightning in Malaysia
title_sort statistical analysis of electric field parameters for negative lightning in malaysia
publisher Elsevier Ltd
publishDate 2016
url http://eprints.utm.my/id/eprint/74476/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84979300121&doi=10.1016%2fj.jastp.2016.05.007&partnerID=40&md5=5cc3e4eda247d6b647453da3f6cfdb37
_version_ 1643656863355502592
score 13.160551