An optimized method of partial discharge data retrieval technique for phase resolved pattern

The measurement of phase resolved partial discharge requires a gigantic memory capacity to store all the waves of the PD test results. This limitation eventually hinders the testing. It is necessary to optimize on the aspect of memory storage capability to reduce the storage requirements. In light o...

Full description

Saved in:
Bibliographic Details
Main Authors: Waldi, E. P., Aulia, Aulia, Hazmi, A., Abral, H., Arief, S., Ahmad, M. H.
Format: Article
Language:English
Published: Universitas Ahmad Dahlan 2016
Subjects:
Online Access:http://eprints.utm.my/id/eprint/73852/1/EkaPutraWaldi2016_AnOptimisedMethodofPartialDischargeDataRetrieval.pdf
http://eprints.utm.my/id/eprint/73852/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84964703280&doi=10.12928%2fTELKOMNIKA.v14i1.2602&partnerID=40&md5=fd6848e9988bab7ca0d0e1476bcb8e2d
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.73852
record_format eprints
spelling my.utm.738522017-11-20T01:04:23Z http://eprints.utm.my/id/eprint/73852/ An optimized method of partial discharge data retrieval technique for phase resolved pattern Waldi, E. P. Aulia, Aulia Hazmi, A. Abral, H. Arief, S. Ahmad, M. H. TK Electrical engineering. Electronics Nuclear engineering The measurement of phase resolved partial discharge requires a gigantic memory capacity to store all the waves of the PD test results. This limitation eventually hinders the testing. It is necessary to optimize on the aspect of memory storage capability to reduce the storage requirements. In light of foregoing, the partial discharge data retrieval techniques with sampling rate methods were used to detect the peak of partial discharge as well as the PD constituent representatives. The optimization process was performed by using integration of oscilloscope and LabVIEW software. The partial discharge data recording can be easily confined to the points of the partial discharge occurrence only. As results, the storage points were reduced by taking wave magnitude associated with PD, thereby resulting in more representative data. Therefore, this optimized method was able to reduce the file size of the test results up to 99 percent of PD original size thereby decreasing the usage of hard disk storage. Universitas Ahmad Dahlan 2016 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/73852/1/EkaPutraWaldi2016_AnOptimisedMethodofPartialDischargeDataRetrieval.pdf Waldi, E. P. and Aulia, Aulia and Hazmi, A. and Abral, H. and Arief, S. and Ahmad, M. H. (2016) An optimized method of partial discharge data retrieval technique for phase resolved pattern. Telkomnika (Telecommunication Computing Electronics and Control), 14 (1). pp. 21-28. ISSN 1693-6930 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84964703280&doi=10.12928%2fTELKOMNIKA.v14i1.2602&partnerID=40&md5=fd6848e9988bab7ca0d0e1476bcb8e2d
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Waldi, E. P.
Aulia, Aulia
Hazmi, A.
Abral, H.
Arief, S.
Ahmad, M. H.
An optimized method of partial discharge data retrieval technique for phase resolved pattern
description The measurement of phase resolved partial discharge requires a gigantic memory capacity to store all the waves of the PD test results. This limitation eventually hinders the testing. It is necessary to optimize on the aspect of memory storage capability to reduce the storage requirements. In light of foregoing, the partial discharge data retrieval techniques with sampling rate methods were used to detect the peak of partial discharge as well as the PD constituent representatives. The optimization process was performed by using integration of oscilloscope and LabVIEW software. The partial discharge data recording can be easily confined to the points of the partial discharge occurrence only. As results, the storage points were reduced by taking wave magnitude associated with PD, thereby resulting in more representative data. Therefore, this optimized method was able to reduce the file size of the test results up to 99 percent of PD original size thereby decreasing the usage of hard disk storage.
format Article
author Waldi, E. P.
Aulia, Aulia
Hazmi, A.
Abral, H.
Arief, S.
Ahmad, M. H.
author_facet Waldi, E. P.
Aulia, Aulia
Hazmi, A.
Abral, H.
Arief, S.
Ahmad, M. H.
author_sort Waldi, E. P.
title An optimized method of partial discharge data retrieval technique for phase resolved pattern
title_short An optimized method of partial discharge data retrieval technique for phase resolved pattern
title_full An optimized method of partial discharge data retrieval technique for phase resolved pattern
title_fullStr An optimized method of partial discharge data retrieval technique for phase resolved pattern
title_full_unstemmed An optimized method of partial discharge data retrieval technique for phase resolved pattern
title_sort optimized method of partial discharge data retrieval technique for phase resolved pattern
publisher Universitas Ahmad Dahlan
publishDate 2016
url http://eprints.utm.my/id/eprint/73852/1/EkaPutraWaldi2016_AnOptimisedMethodofPartialDischargeDataRetrieval.pdf
http://eprints.utm.my/id/eprint/73852/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84964703280&doi=10.12928%2fTELKOMNIKA.v14i1.2602&partnerID=40&md5=fd6848e9988bab7ca0d0e1476bcb8e2d
_version_ 1643656766417797120
score 13.18916