Use of vibration ods for structural integrity assessment of large engineering structures

Operating deflection shape (ODS) is a proven technique in vibration analysis - often used for machines and structures. This paper reviews practical difficulties in the use of vibration ODS in fault diagnosis and structural integrity assessment of large engineering structures. The challenges are inhe...

Full description

Saved in:
Bibliographic Details
Main Authors: Leong, M. S., Lim, M. H.
Format: Conference or Workshop Item
Published: International Institute of Acoustics and Vibrations 2016
Subjects:
Online Access:http://eprints.utm.my/id/eprint/73528/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84987904211&partnerID=40&md5=d360d552d24c05b82413dbf2d23136c7
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.73528
record_format eprints
spelling my.utm.735282017-11-26T03:37:06Z http://eprints.utm.my/id/eprint/73528/ Use of vibration ods for structural integrity assessment of large engineering structures Leong, M. S. Lim, M. H. TK Electrical engineering. Electronics Nuclear engineering Operating deflection shape (ODS) is a proven technique in vibration analysis - often used for machines and structures. This paper reviews practical difficulties in the use of vibration ODS in fault diagnosis and structural integrity assessment of large engineering structures. The challenges are inherent in the number of measurement locations over large distances for which phase matched measurements are required where the structure is often subjected to varying load conditions with multiple excitation sources at different locations. Using a case study of a large concrete structure supporting a polymerization rector in a petrochemical plant, the paper describes procedures used in site measurements to obtain ODS undertaken to identify likely causes of vibration. This was followed by structural integrity assessment of the structure using finite element analysis collaborated with the actual measured experimental modal analysis of the structure. The challenge was to identify root causes correlated to process operations, and assessment of structural integrity of the structure. Results of the ODS were used to validate Finite Element Analysis of the structure. Using the validated FEA model, dynamic response and stresses in the structure were obtained for structural integrity assessment. The FEA predictions showed likely locations of high stress which were consistent with actual damage and incipient failure locations in the real structure. International Institute of Acoustics and Vibrations 2016 Conference or Workshop Item PeerReviewed Leong, M. S. and Lim, M. H. (2016) Use of vibration ods for structural integrity assessment of large engineering structures. In: 23rd International Congress on Sound and Vibration, ICSV 2016, 10-14 July 2016, Greece. https://www.scopus.com/inward/record.uri?eid=2-s2.0-84987904211&partnerID=40&md5=d360d552d24c05b82413dbf2d23136c7
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Leong, M. S.
Lim, M. H.
Use of vibration ods for structural integrity assessment of large engineering structures
description Operating deflection shape (ODS) is a proven technique in vibration analysis - often used for machines and structures. This paper reviews practical difficulties in the use of vibration ODS in fault diagnosis and structural integrity assessment of large engineering structures. The challenges are inherent in the number of measurement locations over large distances for which phase matched measurements are required where the structure is often subjected to varying load conditions with multiple excitation sources at different locations. Using a case study of a large concrete structure supporting a polymerization rector in a petrochemical plant, the paper describes procedures used in site measurements to obtain ODS undertaken to identify likely causes of vibration. This was followed by structural integrity assessment of the structure using finite element analysis collaborated with the actual measured experimental modal analysis of the structure. The challenge was to identify root causes correlated to process operations, and assessment of structural integrity of the structure. Results of the ODS were used to validate Finite Element Analysis of the structure. Using the validated FEA model, dynamic response and stresses in the structure were obtained for structural integrity assessment. The FEA predictions showed likely locations of high stress which were consistent with actual damage and incipient failure locations in the real structure.
format Conference or Workshop Item
author Leong, M. S.
Lim, M. H.
author_facet Leong, M. S.
Lim, M. H.
author_sort Leong, M. S.
title Use of vibration ods for structural integrity assessment of large engineering structures
title_short Use of vibration ods for structural integrity assessment of large engineering structures
title_full Use of vibration ods for structural integrity assessment of large engineering structures
title_fullStr Use of vibration ods for structural integrity assessment of large engineering structures
title_full_unstemmed Use of vibration ods for structural integrity assessment of large engineering structures
title_sort use of vibration ods for structural integrity assessment of large engineering structures
publisher International Institute of Acoustics and Vibrations
publishDate 2016
url http://eprints.utm.my/id/eprint/73528/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84987904211&partnerID=40&md5=d360d552d24c05b82413dbf2d23136c7
_version_ 1643656679897694208