Efficient morphological-based edge detection algorithm for computed tomography cardiac images

Medical imaging has been extensively used for disease monitoring, treatment planning, diagnosis and computer aided surgery. Often, the acquired images are raw in nature, thus making them prone to being complex and noisy. A series of preprocessing and information extraction steps are therefore necess...

Full description

Saved in:
Bibliographic Details
Main Authors: Chieng, T. M., Omar, Z., Kadiman, S.
Format: Conference or Workshop Item
Published: Institute of Electrical and Electronics Engineers Inc. 2016
Subjects:
Online Access:http://eprints.utm.my/id/eprint/73383/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84971607306&doi=10.1109%2fICSIPA.2015.7412228&partnerID=40&md5=d4af7356d3ca112390d9dbc0bc883950
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.73383
record_format eprints
spelling my.utm.733832017-11-21T08:17:09Z http://eprints.utm.my/id/eprint/73383/ Efficient morphological-based edge detection algorithm for computed tomography cardiac images Chieng, T. M. Omar, Z. Kadiman, S. TK Electrical engineering. Electronics Nuclear engineering Medical imaging has been extensively used for disease monitoring, treatment planning, diagnosis and computer aided surgery. Often, the acquired images are raw in nature, thus making them prone to being complex and noisy. A series of preprocessing and information extraction steps are therefore necessary in order for the relevant information to reach the medical practitioner. To this end, image denoising and edge detection play a vital role as a precursor to more advanced techniques in the medical image processing field. In this paper we have proposed an innovative mathematical morphology-based image denoising and edge detection method, for pre-processing of computed tomography (CT) images of the human heart. The morphological edge detection algorithm together with six different shaped structuring elements are implemented to preserve and detect the edges of the CT image while effectively suppressing noise, all at low computational cost. The experimental results affirm our approach's efficiency and capability in denoising and detecting salient edges from corrupted and complex medical images. Institute of Electrical and Electronics Engineers Inc. 2016 Conference or Workshop Item PeerReviewed Chieng, T. M. and Omar, Z. and Kadiman, S. (2016) Efficient morphological-based edge detection algorithm for computed tomography cardiac images. In: 4th IEEE International Conference on Signal and Image Processing Applications, ICSIPA 2015, 19-21 Oct 2015, Kuala Lumpur, Malaysia. https://www.scopus.com/inward/record.uri?eid=2-s2.0-84971607306&doi=10.1109%2fICSIPA.2015.7412228&partnerID=40&md5=d4af7356d3ca112390d9dbc0bc883950
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Chieng, T. M.
Omar, Z.
Kadiman, S.
Efficient morphological-based edge detection algorithm for computed tomography cardiac images
description Medical imaging has been extensively used for disease monitoring, treatment planning, diagnosis and computer aided surgery. Often, the acquired images are raw in nature, thus making them prone to being complex and noisy. A series of preprocessing and information extraction steps are therefore necessary in order for the relevant information to reach the medical practitioner. To this end, image denoising and edge detection play a vital role as a precursor to more advanced techniques in the medical image processing field. In this paper we have proposed an innovative mathematical morphology-based image denoising and edge detection method, for pre-processing of computed tomography (CT) images of the human heart. The morphological edge detection algorithm together with six different shaped structuring elements are implemented to preserve and detect the edges of the CT image while effectively suppressing noise, all at low computational cost. The experimental results affirm our approach's efficiency and capability in denoising and detecting salient edges from corrupted and complex medical images.
format Conference or Workshop Item
author Chieng, T. M.
Omar, Z.
Kadiman, S.
author_facet Chieng, T. M.
Omar, Z.
Kadiman, S.
author_sort Chieng, T. M.
title Efficient morphological-based edge detection algorithm for computed tomography cardiac images
title_short Efficient morphological-based edge detection algorithm for computed tomography cardiac images
title_full Efficient morphological-based edge detection algorithm for computed tomography cardiac images
title_fullStr Efficient morphological-based edge detection algorithm for computed tomography cardiac images
title_full_unstemmed Efficient morphological-based edge detection algorithm for computed tomography cardiac images
title_sort efficient morphological-based edge detection algorithm for computed tomography cardiac images
publisher Institute of Electrical and Electronics Engineers Inc.
publishDate 2016
url http://eprints.utm.my/id/eprint/73383/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84971607306&doi=10.1109%2fICSIPA.2015.7412228&partnerID=40&md5=d4af7356d3ca112390d9dbc0bc883950
_version_ 1643656647757791232