Specific Absorption Rate in the human leg and testicle due to metallic coin and zip

This research identifies and evaluates the effect of human body and conductive metallic objects in the vicinity of radiation source on Specific Absorption Rate (SAR). The presence of electronic devices in the vicinity of human body especially close to the human sensitive part especially when the ant...

Full description

Saved in:
Bibliographic Details
Main Authors: Othman, N., Samsuri, N. A., Rahim, M. K. A., Elias, N. A.
Format: Conference or Workshop Item
Published: Institute of Electrical and Electronics Engineers Inc. 2016
Subjects:
Online Access:http://eprints.utm.my/id/eprint/73027/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84995486573&doi=10.1109%2fRFM.2015.7587727&partnerID=40&md5=6e268ad2f3492625ef8ff3a8c3073994
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.73027
record_format eprints
spelling my.utm.730272017-11-29T23:58:41Z http://eprints.utm.my/id/eprint/73027/ Specific Absorption Rate in the human leg and testicle due to metallic coin and zip Othman, N. Samsuri, N. A. Rahim, M. K. A. Elias, N. A. TK Electrical engineering. Electronics Nuclear engineering This research identifies and evaluates the effect of human body and conductive metallic objects in the vicinity of radiation source on Specific Absorption Rate (SAR). The presence of electronic devices in the vicinity of human body especially close to the human sensitive part especially when the antenna is left inside the trousers pocket could allow the radiated electromagnetic wave to penetrate inside human tissue. Realistic Voxel body model has been considered in the simulation. The excitation is provided by means of a simple dipole and PIFA antennas as the radiating source at 0.9 GHz and 1.8 GHz. Metallic coin and zip have been used in order to characterize the variation of SAR due to metallic objects. The results have shown that the presence of metallic objects near to human body could alter the energy absorption by the body. The presence of coin close to dipole antenna increases the 1g SAR in the leg by 58 %. In addition, the zip could significantly increases SAR inside the testicle by 30 % at 0.9 GHz. Institute of Electrical and Electronics Engineers Inc. 2016 Conference or Workshop Item PeerReviewed Othman, N. and Samsuri, N. A. and Rahim, M. K. A. and Elias, N. A. (2016) Specific Absorption Rate in the human leg and testicle due to metallic coin and zip. In: 6th IEEE International RF and Microwave Conference, RFM 2015, 14 December 2015 through 16 December 2015, Sarawak; Malaysia. https://www.scopus.com/inward/record.uri?eid=2-s2.0-84995486573&doi=10.1109%2fRFM.2015.7587727&partnerID=40&md5=6e268ad2f3492625ef8ff3a8c3073994
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Othman, N.
Samsuri, N. A.
Rahim, M. K. A.
Elias, N. A.
Specific Absorption Rate in the human leg and testicle due to metallic coin and zip
description This research identifies and evaluates the effect of human body and conductive metallic objects in the vicinity of radiation source on Specific Absorption Rate (SAR). The presence of electronic devices in the vicinity of human body especially close to the human sensitive part especially when the antenna is left inside the trousers pocket could allow the radiated electromagnetic wave to penetrate inside human tissue. Realistic Voxel body model has been considered in the simulation. The excitation is provided by means of a simple dipole and PIFA antennas as the radiating source at 0.9 GHz and 1.8 GHz. Metallic coin and zip have been used in order to characterize the variation of SAR due to metallic objects. The results have shown that the presence of metallic objects near to human body could alter the energy absorption by the body. The presence of coin close to dipole antenna increases the 1g SAR in the leg by 58 %. In addition, the zip could significantly increases SAR inside the testicle by 30 % at 0.9 GHz.
format Conference or Workshop Item
author Othman, N.
Samsuri, N. A.
Rahim, M. K. A.
Elias, N. A.
author_facet Othman, N.
Samsuri, N. A.
Rahim, M. K. A.
Elias, N. A.
author_sort Othman, N.
title Specific Absorption Rate in the human leg and testicle due to metallic coin and zip
title_short Specific Absorption Rate in the human leg and testicle due to metallic coin and zip
title_full Specific Absorption Rate in the human leg and testicle due to metallic coin and zip
title_fullStr Specific Absorption Rate in the human leg and testicle due to metallic coin and zip
title_full_unstemmed Specific Absorption Rate in the human leg and testicle due to metallic coin and zip
title_sort specific absorption rate in the human leg and testicle due to metallic coin and zip
publisher Institute of Electrical and Electronics Engineers Inc.
publishDate 2016
url http://eprints.utm.my/id/eprint/73027/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84995486573&doi=10.1109%2fRFM.2015.7587727&partnerID=40&md5=6e268ad2f3492625ef8ff3a8c3073994
_version_ 1643656555505123328
score 13.211869