Specific Absorption Rate in the human leg and testicle due to metallic coin and zip
This research identifies and evaluates the effect of human body and conductive metallic objects in the vicinity of radiation source on Specific Absorption Rate (SAR). The presence of electronic devices in the vicinity of human body especially close to the human sensitive part especially when the ant...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Conference or Workshop Item |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2016
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/73027/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-84995486573&doi=10.1109%2fRFM.2015.7587727&partnerID=40&md5=6e268ad2f3492625ef8ff3a8c3073994 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.73027 |
---|---|
record_format |
eprints |
spelling |
my.utm.730272017-11-29T23:58:41Z http://eprints.utm.my/id/eprint/73027/ Specific Absorption Rate in the human leg and testicle due to metallic coin and zip Othman, N. Samsuri, N. A. Rahim, M. K. A. Elias, N. A. TK Electrical engineering. Electronics Nuclear engineering This research identifies and evaluates the effect of human body and conductive metallic objects in the vicinity of radiation source on Specific Absorption Rate (SAR). The presence of electronic devices in the vicinity of human body especially close to the human sensitive part especially when the antenna is left inside the trousers pocket could allow the radiated electromagnetic wave to penetrate inside human tissue. Realistic Voxel body model has been considered in the simulation. The excitation is provided by means of a simple dipole and PIFA antennas as the radiating source at 0.9 GHz and 1.8 GHz. Metallic coin and zip have been used in order to characterize the variation of SAR due to metallic objects. The results have shown that the presence of metallic objects near to human body could alter the energy absorption by the body. The presence of coin close to dipole antenna increases the 1g SAR in the leg by 58 %. In addition, the zip could significantly increases SAR inside the testicle by 30 % at 0.9 GHz. Institute of Electrical and Electronics Engineers Inc. 2016 Conference or Workshop Item PeerReviewed Othman, N. and Samsuri, N. A. and Rahim, M. K. A. and Elias, N. A. (2016) Specific Absorption Rate in the human leg and testicle due to metallic coin and zip. In: 6th IEEE International RF and Microwave Conference, RFM 2015, 14 December 2015 through 16 December 2015, Sarawak; Malaysia. https://www.scopus.com/inward/record.uri?eid=2-s2.0-84995486573&doi=10.1109%2fRFM.2015.7587727&partnerID=40&md5=6e268ad2f3492625ef8ff3a8c3073994 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Othman, N. Samsuri, N. A. Rahim, M. K. A. Elias, N. A. Specific Absorption Rate in the human leg and testicle due to metallic coin and zip |
description |
This research identifies and evaluates the effect of human body and conductive metallic objects in the vicinity of radiation source on Specific Absorption Rate (SAR). The presence of electronic devices in the vicinity of human body especially close to the human sensitive part especially when the antenna is left inside the trousers pocket could allow the radiated electromagnetic wave to penetrate inside human tissue. Realistic Voxel body model has been considered in the simulation. The excitation is provided by means of a simple dipole and PIFA antennas as the radiating source at 0.9 GHz and 1.8 GHz. Metallic coin and zip have been used in order to characterize the variation of SAR due to metallic objects. The results have shown that the presence of metallic objects near to human body could alter the energy absorption by the body. The presence of coin close to dipole antenna increases the 1g SAR in the leg by 58 %. In addition, the zip could significantly increases SAR inside the testicle by 30 % at 0.9 GHz. |
format |
Conference or Workshop Item |
author |
Othman, N. Samsuri, N. A. Rahim, M. K. A. Elias, N. A. |
author_facet |
Othman, N. Samsuri, N. A. Rahim, M. K. A. Elias, N. A. |
author_sort |
Othman, N. |
title |
Specific Absorption Rate in the human leg and testicle due to metallic coin and zip |
title_short |
Specific Absorption Rate in the human leg and testicle due to metallic coin and zip |
title_full |
Specific Absorption Rate in the human leg and testicle due to metallic coin and zip |
title_fullStr |
Specific Absorption Rate in the human leg and testicle due to metallic coin and zip |
title_full_unstemmed |
Specific Absorption Rate in the human leg and testicle due to metallic coin and zip |
title_sort |
specific absorption rate in the human leg and testicle due to metallic coin and zip |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2016 |
url |
http://eprints.utm.my/id/eprint/73027/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-84995486573&doi=10.1109%2fRFM.2015.7587727&partnerID=40&md5=6e268ad2f3492625ef8ff3a8c3073994 |
_version_ |
1643656555505123328 |
score |
13.211869 |