Low cost digital close range photogrammetric measurement of an as-built anchor handling tug hull
A close range photogrammetric (CRP) model of an as-built 40 m anchor handling tug hull located in an open space shipyard was constructed in this study through the use of a low cost amateur digital single-lens reflex camera, together with a modestly priced photogrammetric software. Through a series o...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Published: |
Elsevier Ltd
2016
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/72486/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-84968764385&doi=10.1016%2fj.oceaneng.2016.04.016&partnerID=40&md5=d4f67acb7efc78c0db49fcbf95dbc3f7 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.72486 |
---|---|
record_format |
eprints |
spelling |
my.utm.724862017-11-27T03:53:16Z http://eprints.utm.my/id/eprint/72486/ Low cost digital close range photogrammetric measurement of an as-built anchor handling tug hull Tang, C. H. H. Tang, H. E. Tay, P. K. J. TJ Mechanical engineering and machinery A close range photogrammetric (CRP) model of an as-built 40 m anchor handling tug hull located in an open space shipyard was constructed in this study through the use of a low cost amateur digital single-lens reflex camera, together with a modestly priced photogrammetric software. Through a series of comprehensive statistical tests, the constructed CRP tug hull model was quantitatively evaluated and analyzed by comparing the CRP measurements with the manually measured tug hull offset data from a lines-plan drawing. The statistical tests showed that most of the measured target coordinates were considerably accurate in this study, with absolute mean of error 4.1 mm and absolute standard deviation of error ±4.5 mm. Paired Student t-test showed that the modeled CRP Z-offset data (ZCRP) is not statistically different from the actual Z-offset data, ZOFF (p>0.05). Linear regression analysis also illustrates a near perfect linear relationship between these two variables. The accuracy achieved in this study is considerably good and sufficient for usual metrological measurement in small- or medium-sized shipbuilding industry, despites the presence of disturbances related to the characteristics of the open space shipyard. In future, a better targeting approach or target material should be used to further improve the CRP measurement accuracy. Elsevier Ltd 2016 Article PeerReviewed Tang, C. H. H. and Tang, H. E. and Tay, P. K. J. (2016) Low cost digital close range photogrammetric measurement of an as-built anchor handling tug hull. Ocean Engineering, 119 . pp. 67-74. ISSN 0029-8018 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84968764385&doi=10.1016%2fj.oceaneng.2016.04.016&partnerID=40&md5=d4f67acb7efc78c0db49fcbf95dbc3f7 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery Tang, C. H. H. Tang, H. E. Tay, P. K. J. Low cost digital close range photogrammetric measurement of an as-built anchor handling tug hull |
description |
A close range photogrammetric (CRP) model of an as-built 40 m anchor handling tug hull located in an open space shipyard was constructed in this study through the use of a low cost amateur digital single-lens reflex camera, together with a modestly priced photogrammetric software. Through a series of comprehensive statistical tests, the constructed CRP tug hull model was quantitatively evaluated and analyzed by comparing the CRP measurements with the manually measured tug hull offset data from a lines-plan drawing. The statistical tests showed that most of the measured target coordinates were considerably accurate in this study, with absolute mean of error 4.1 mm and absolute standard deviation of error ±4.5 mm. Paired Student t-test showed that the modeled CRP Z-offset data (ZCRP) is not statistically different from the actual Z-offset data, ZOFF (p>0.05). Linear regression analysis also illustrates a near perfect linear relationship between these two variables. The accuracy achieved in this study is considerably good and sufficient for usual metrological measurement in small- or medium-sized shipbuilding industry, despites the presence of disturbances related to the characteristics of the open space shipyard. In future, a better targeting approach or target material should be used to further improve the CRP measurement accuracy. |
format |
Article |
author |
Tang, C. H. H. Tang, H. E. Tay, P. K. J. |
author_facet |
Tang, C. H. H. Tang, H. E. Tay, P. K. J. |
author_sort |
Tang, C. H. H. |
title |
Low cost digital close range photogrammetric measurement of an as-built anchor handling tug hull |
title_short |
Low cost digital close range photogrammetric measurement of an as-built anchor handling tug hull |
title_full |
Low cost digital close range photogrammetric measurement of an as-built anchor handling tug hull |
title_fullStr |
Low cost digital close range photogrammetric measurement of an as-built anchor handling tug hull |
title_full_unstemmed |
Low cost digital close range photogrammetric measurement of an as-built anchor handling tug hull |
title_sort |
low cost digital close range photogrammetric measurement of an as-built anchor handling tug hull |
publisher |
Elsevier Ltd |
publishDate |
2016 |
url |
http://eprints.utm.my/id/eprint/72486/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-84968764385&doi=10.1016%2fj.oceaneng.2016.04.016&partnerID=40&md5=d4f67acb7efc78c0db49fcbf95dbc3f7 |
_version_ |
1643656454479020032 |
score |
13.160551 |