MOCUM solutions and sensitivity study for C5G7 benchmark

This work uses the 2-D C5G7 benchmark to verify the accuracy and efficiency of the MOCUM code, a parallel neutronics program based on the method of characteristics (MOC) for arbitrary core geometries. Compared to references, MOCUM keff, assembly and pin power maximum percentage errors are 0.02%, −0....

Full description

Saved in:
Bibliographic Details
Main Authors: Yang, X., Borse, R., Satvat, N.
Format: Article
Published: Elsevier Ltd 2016
Subjects:
Online Access:http://eprints.utm.my/id/eprint/71998/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84973855953&doi=10.1016%2fj.anucene.2016.05.030&partnerID=40&md5=ab69d66a138314c869b1cf969a204f89
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.71998
record_format eprints
spelling my.utm.719982017-11-16T05:25:11Z http://eprints.utm.my/id/eprint/71998/ MOCUM solutions and sensitivity study for C5G7 benchmark Yang, X. Borse, R. Satvat, N. TP Chemical technology This work uses the 2-D C5G7 benchmark to verify the accuracy and efficiency of the MOCUM code, a parallel neutronics program based on the method of characteristics (MOC) for arbitrary core geometries. Compared to references, MOCUM keff, assembly and pin power maximum percentage errors are 0.02%, −0.06%, and 0.64%, respectively. The parallel algorithm achieves speed-ups of more than 17 times, compared to the calculation speed using one thread. The sensitivity study of various MOC parameters reveals that the C5G7 benchmark problem requires 48 or more azimuthal angles. The strong flux gradient and the heterogeneous effects demand fine unstructured meshes to yield accurate flux solution. The simulation uses 258 million zones with an average mesh size of 0.016 cm2. The investigation of the polar angle quadrature indicates that Leonard polar angle performs slightly better and more than three polar angles are not necessary. In addition, parameter sensitivity study shows that coarse parameters are prone to introduce error to the neutron flux but not keff. Elsevier Ltd 2016 Article PeerReviewed Yang, X. and Borse, R. and Satvat, N. (2016) MOCUM solutions and sensitivity study for C5G7 benchmark. Annals of Nuclear Energy, 96 . pp. 242-248. ISSN 0306-4549 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84973855953&doi=10.1016%2fj.anucene.2016.05.030&partnerID=40&md5=ab69d66a138314c869b1cf969a204f89
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TP Chemical technology
spellingShingle TP Chemical technology
Yang, X.
Borse, R.
Satvat, N.
MOCUM solutions and sensitivity study for C5G7 benchmark
description This work uses the 2-D C5G7 benchmark to verify the accuracy and efficiency of the MOCUM code, a parallel neutronics program based on the method of characteristics (MOC) for arbitrary core geometries. Compared to references, MOCUM keff, assembly and pin power maximum percentage errors are 0.02%, −0.06%, and 0.64%, respectively. The parallel algorithm achieves speed-ups of more than 17 times, compared to the calculation speed using one thread. The sensitivity study of various MOC parameters reveals that the C5G7 benchmark problem requires 48 or more azimuthal angles. The strong flux gradient and the heterogeneous effects demand fine unstructured meshes to yield accurate flux solution. The simulation uses 258 million zones with an average mesh size of 0.016 cm2. The investigation of the polar angle quadrature indicates that Leonard polar angle performs slightly better and more than three polar angles are not necessary. In addition, parameter sensitivity study shows that coarse parameters are prone to introduce error to the neutron flux but not keff.
format Article
author Yang, X.
Borse, R.
Satvat, N.
author_facet Yang, X.
Borse, R.
Satvat, N.
author_sort Yang, X.
title MOCUM solutions and sensitivity study for C5G7 benchmark
title_short MOCUM solutions and sensitivity study for C5G7 benchmark
title_full MOCUM solutions and sensitivity study for C5G7 benchmark
title_fullStr MOCUM solutions and sensitivity study for C5G7 benchmark
title_full_unstemmed MOCUM solutions and sensitivity study for C5G7 benchmark
title_sort mocum solutions and sensitivity study for c5g7 benchmark
publisher Elsevier Ltd
publishDate 2016
url http://eprints.utm.my/id/eprint/71998/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84973855953&doi=10.1016%2fj.anucene.2016.05.030&partnerID=40&md5=ab69d66a138314c869b1cf969a204f89
_version_ 1643656333349617664
score 13.211869