The main objective of this study was to determine the reliability of using microfiltration system which is composed of a coagulant such as ferric chloride (pretreatment substance) and hollow fibre membrane as filtering medium for improving water quality. In this study, raw water samples were collect...

Full description

Saved in:
Bibliographic Details
Main Authors: Noor, M. J. M. M., Mohammad, T. A., Ghazali, A. H.
Format: Article
Published: Taylor and Francis Inc. 2016
Subjects:
Online Access:http://eprints.utm.my/id/eprint/71764/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84955117900&doi=10.1080%2f19443994.2015.1133875&partnerID=40&md5=8cb80ec47a81f02f0a597213ada5fc5b
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.71764
record_format eprints
spelling my.utm.717642017-11-15T03:28:39Z http://eprints.utm.my/id/eprint/71764/ Assessment of using hollow fibre microfiltration in treating lake water Noor, M. J. M. M. Mohammad, T. A. Ghazali, A. H. TP Chemical technology The main objective of this study was to determine the reliability of using microfiltration system which is composed of a coagulant such as ferric chloride (pretreatment substance) and hollow fibre membrane as filtering medium for improving water quality. In this study, raw water samples were collected from a lake located at the Faculty of Engineering, Universiti Putra Malaysia. The experiments were carried out in three stages: the first stage used distilled water, the second stage used lake water stored in a tank and the third stage used lake water stored in the tank and mixed with ferric chloride as coagulant. A storage tank and a separation tank were used; the storage tank is used to store water pumped from the lake (used in the second stage) while in the third stage, the stored water in tank was used for pretreatment or coagulation with optimum dosage of ferric chloride (determined from jar test). The experimental results show that the flux obtained from second and third stages was low. For lake water stage, the best flux was found to be 4.97Â l/m2/h. The distilled water stage shows that shaft rotational speed of peristaltic pump was one of the factors affecting the flux. Therefore, a pump shaft rotational speed of 7Â rpm was chosen based on flux and suction pressure. The experimental results show the ability of microfiltration using hollow fibre membrane together with ferric chloride as coagulant to produce treated water with 97% turbidity removal and 85% removal of total suspended solids (TSS). For treated raw water, it is found that the removals of TSS were ranged from 71.7 to 91.6% when alum was used as a coagulant while the TSS removals were ranged from 74.4 to 89.20% when ferric chloride was used as a coagulant. In this study, it is found that the optimum dosages of ferric chloride and alum were 4 and 20Â mg/l, respectively. Although the percentage removal of TSS is slightly higher when alum is used as a coagulant compared with using ferric chloride, it is recommended to use ferric chloride as a coagulant due to its economical and health advantages. Furthermore, ferric chloride can be used in wide range of pH values while alum can only be effective when pH value around 7. Taylor and Francis Inc. 2016 Article PeerReviewed Noor, M. J. M. M. and Mohammad, T. A. and Ghazali, A. H. (2016) Assessment of using hollow fibre microfiltration in treating lake water. Desalination and Water Treatment, 57 (48-49). pp. 23232-23245. ISSN 1944-3994 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84955117900&doi=10.1080%2f19443994.2015.1133875&partnerID=40&md5=8cb80ec47a81f02f0a597213ada5fc5b
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TP Chemical technology
spellingShingle TP Chemical technology
Noor, M. J. M. M.
Mohammad, T. A.
Ghazali, A. H.
Assessment of using hollow fibre microfiltration in treating lake water
description The main objective of this study was to determine the reliability of using microfiltration system which is composed of a coagulant such as ferric chloride (pretreatment substance) and hollow fibre membrane as filtering medium for improving water quality. In this study, raw water samples were collected from a lake located at the Faculty of Engineering, Universiti Putra Malaysia. The experiments were carried out in three stages: the first stage used distilled water, the second stage used lake water stored in a tank and the third stage used lake water stored in the tank and mixed with ferric chloride as coagulant. A storage tank and a separation tank were used; the storage tank is used to store water pumped from the lake (used in the second stage) while in the third stage, the stored water in tank was used for pretreatment or coagulation with optimum dosage of ferric chloride (determined from jar test). The experimental results show that the flux obtained from second and third stages was low. For lake water stage, the best flux was found to be 4.97Â l/m2/h. The distilled water stage shows that shaft rotational speed of peristaltic pump was one of the factors affecting the flux. Therefore, a pump shaft rotational speed of 7Â rpm was chosen based on flux and suction pressure. The experimental results show the ability of microfiltration using hollow fibre membrane together with ferric chloride as coagulant to produce treated water with 97% turbidity removal and 85% removal of total suspended solids (TSS). For treated raw water, it is found that the removals of TSS were ranged from 71.7 to 91.6% when alum was used as a coagulant while the TSS removals were ranged from 74.4 to 89.20% when ferric chloride was used as a coagulant. In this study, it is found that the optimum dosages of ferric chloride and alum were 4 and 20Â mg/l, respectively. Although the percentage removal of TSS is slightly higher when alum is used as a coagulant compared with using ferric chloride, it is recommended to use ferric chloride as a coagulant due to its economical and health advantages. Furthermore, ferric chloride can be used in wide range of pH values while alum can only be effective when pH value around 7.
format Article
author Noor, M. J. M. M.
Mohammad, T. A.
Ghazali, A. H.
author_facet Noor, M. J. M. M.
Mohammad, T. A.
Ghazali, A. H.
author_sort Noor, M. J. M. M.
title Assessment of using hollow fibre microfiltration in treating lake water
title_short Assessment of using hollow fibre microfiltration in treating lake water
title_full Assessment of using hollow fibre microfiltration in treating lake water
title_fullStr Assessment of using hollow fibre microfiltration in treating lake water
title_full_unstemmed Assessment of using hollow fibre microfiltration in treating lake water
title_sort assessment of using hollow fibre microfiltration in treating lake water
publisher Taylor and Francis Inc.
publishDate 2016
url http://eprints.utm.my/id/eprint/71764/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84955117900&doi=10.1080%2f19443994.2015.1133875&partnerID=40&md5=8cb80ec47a81f02f0a597213ada5fc5b
_version_ 1643656274073616384
score 13.160551