The evaluation of hydroxyapatite (HA) coated and uncoated porous tantalum for biomedical material applications

Porous tantalum has been used as an orthopedic implant for bone defects as it has a good corrosion resistance and fatigue behaviour properties. However, there are some reports on the rejection of porous Ta after the implantation. Those clinical cases refer to the less bioactivity of metallic-based m...

Full description

Saved in:
Bibliographic Details
Main Authors: Safuan, Nadia, Sukmana, Irza, Abdul Kadir, Mohammed Rafiq, Noviana, Deni
Format: Conference or Workshop Item
Published: 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/68559/
http://dx.doi.org/10.1088/1742-6596/495/1/012023
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.68559
record_format eprints
spelling my.utm.685592017-10-08T03:26:49Z http://eprints.utm.my/id/eprint/68559/ The evaluation of hydroxyapatite (HA) coated and uncoated porous tantalum for biomedical material applications Safuan, Nadia Sukmana, Irza Abdul Kadir, Mohammed Rafiq Noviana, Deni R Medicine (General) Porous tantalum has been used as an orthopedic implant for bone defects as it has a good corrosion resistance and fatigue behaviour properties. However, there are some reports on the rejection of porous Ta after the implantation. Those clinical cases refer to the less bioactivity of metallic-based materials. This study aims to evaluate hydroxyapatite coated and uncoated porous Tantalum in order to improve the biocompatibility of porous tantalum implant and osseointegration. Porous tantalum was used as metallic-base substrate and hydroxyapatite coating has been done using plasma-spraying technique. Scanning Electron Microscopy (SEM) and Field Emission Scanning Electron Microscopy (FESEM) techniques were utilizes to investigate the coating characteristics while Confocal Raman Microscopy to investigate the interface and image. The effect of coating to the corrosion behaviour was assessed by employing potentiodynamic polarization tests in simulated body fluid at 37 +/- 1 degrees C. Based on SEM and FESEM results, the morphologies as well the weight element consists in the uncoated and hydroxyapatite coated porous tantalum were revealed. The results indicated that the decrease in corrosion current density for HA coated porous Ta compared to the uncoated porous Ta. This study concluded that by coating porous tantalum with HA supports to decrease the corrosion rate of pure porous. 2015 Conference or Workshop Item PeerReviewed Safuan, Nadia and Sukmana, Irza and Abdul Kadir, Mohammed Rafiq and Noviana, Deni (2015) The evaluation of hydroxyapatite (HA) coated and uncoated porous tantalum for biomedical material applications. In: International Conference on Science and Engineering in Mathematics, Chemistry and Physics (ScieTech), 13-14 Jan, 2014, Indonesia. http://dx.doi.org/10.1088/1742-6596/495/1/012023
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic R Medicine (General)
spellingShingle R Medicine (General)
Safuan, Nadia
Sukmana, Irza
Abdul Kadir, Mohammed Rafiq
Noviana, Deni
The evaluation of hydroxyapatite (HA) coated and uncoated porous tantalum for biomedical material applications
description Porous tantalum has been used as an orthopedic implant for bone defects as it has a good corrosion resistance and fatigue behaviour properties. However, there are some reports on the rejection of porous Ta after the implantation. Those clinical cases refer to the less bioactivity of metallic-based materials. This study aims to evaluate hydroxyapatite coated and uncoated porous Tantalum in order to improve the biocompatibility of porous tantalum implant and osseointegration. Porous tantalum was used as metallic-base substrate and hydroxyapatite coating has been done using plasma-spraying technique. Scanning Electron Microscopy (SEM) and Field Emission Scanning Electron Microscopy (FESEM) techniques were utilizes to investigate the coating characteristics while Confocal Raman Microscopy to investigate the interface and image. The effect of coating to the corrosion behaviour was assessed by employing potentiodynamic polarization tests in simulated body fluid at 37 +/- 1 degrees C. Based on SEM and FESEM results, the morphologies as well the weight element consists in the uncoated and hydroxyapatite coated porous tantalum were revealed. The results indicated that the decrease in corrosion current density for HA coated porous Ta compared to the uncoated porous Ta. This study concluded that by coating porous tantalum with HA supports to decrease the corrosion rate of pure porous.
format Conference or Workshop Item
author Safuan, Nadia
Sukmana, Irza
Abdul Kadir, Mohammed Rafiq
Noviana, Deni
author_facet Safuan, Nadia
Sukmana, Irza
Abdul Kadir, Mohammed Rafiq
Noviana, Deni
author_sort Safuan, Nadia
title The evaluation of hydroxyapatite (HA) coated and uncoated porous tantalum for biomedical material applications
title_short The evaluation of hydroxyapatite (HA) coated and uncoated porous tantalum for biomedical material applications
title_full The evaluation of hydroxyapatite (HA) coated and uncoated porous tantalum for biomedical material applications
title_fullStr The evaluation of hydroxyapatite (HA) coated and uncoated porous tantalum for biomedical material applications
title_full_unstemmed The evaluation of hydroxyapatite (HA) coated and uncoated porous tantalum for biomedical material applications
title_sort evaluation of hydroxyapatite (ha) coated and uncoated porous tantalum for biomedical material applications
publishDate 2015
url http://eprints.utm.my/id/eprint/68559/
http://dx.doi.org/10.1088/1742-6596/495/1/012023
_version_ 1643655958872719360
score 13.19449