In-plane sway behaviour of slender cold-formed steel bolted frames

The use of light steel frames in rapid construction has grown significantly, especially concerning low and medium-rise buildings. However, there are limited resources available regarding the sway stiffness of light steel frames with flexible bolted joints. This paper presents a study on the lateral...

Full description

Saved in:
Bibliographic Details
Main Authors: Yeong, Huei Lee, Tan, Cher Siang, Mohammad, Shahrin
Format: Article
Published: Elsevier 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/66500/
http://dx.doi.org/10.1016/j.tws.2017.01.024
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.66500
record_format eprints
spelling my.utm.665002017-10-03T13:33:13Z http://eprints.utm.my/id/eprint/66500/ In-plane sway behaviour of slender cold-formed steel bolted frames Yeong, Huei Lee Tan, Cher Siang Mohammad, Shahrin TA Engineering (General). Civil engineering (General) HD Industries. Land use. Labor The use of light steel frames in rapid construction has grown significantly, especially concerning low and medium-rise buildings. However, there are limited resources available regarding the sway stiffness of light steel frames with flexible bolted joints. This paper presents a study on the lateral sway behaviour for light steel frames with bolted top-seat flange cleat connections comprising slender cold-formed steel sections. Two different sections, flexibility of beam-to-column joint and base conditions are the investigated variables. The result recorded showed that geometrics, joint flexibility and base conditions affect the sway stiffness of light steel frame. The increase rate is ranged from 29.2% to 47.5% for the identical tests for the effect of section depth. The ratio lies between 1.10 and 3.04 for the effect of connector thickness. In addition, beam-to-column bolted connections can contribute 34–88% of the overall frame elastic lateral stiffness for pinned bases and 17–33% for rigid base connections. Frame stability analysis with respect to global frame and column design were performed for the test specimens. Appropriate frame design analysis should be determined to provide a safe and reliable design for light steel frame considering bolted flexible joints and slender cold-formed steel sections. Elsevier 2017-01-05 Article PeerReviewed Yeong, Huei Lee and Tan, Cher Siang and Mohammad, Shahrin (2017) In-plane sway behaviour of slender cold-formed steel bolted frames. Thin-Walled Structures, 114 . pp. 11-21. ISSN 0263-8231 http://dx.doi.org/10.1016/j.tws.2017.01.024 DOI:10.1016/j.tws.2017.01.024
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TA Engineering (General). Civil engineering (General)
HD Industries. Land use. Labor
spellingShingle TA Engineering (General). Civil engineering (General)
HD Industries. Land use. Labor
Yeong, Huei Lee
Tan, Cher Siang
Mohammad, Shahrin
In-plane sway behaviour of slender cold-formed steel bolted frames
description The use of light steel frames in rapid construction has grown significantly, especially concerning low and medium-rise buildings. However, there are limited resources available regarding the sway stiffness of light steel frames with flexible bolted joints. This paper presents a study on the lateral sway behaviour for light steel frames with bolted top-seat flange cleat connections comprising slender cold-formed steel sections. Two different sections, flexibility of beam-to-column joint and base conditions are the investigated variables. The result recorded showed that geometrics, joint flexibility and base conditions affect the sway stiffness of light steel frame. The increase rate is ranged from 29.2% to 47.5% for the identical tests for the effect of section depth. The ratio lies between 1.10 and 3.04 for the effect of connector thickness. In addition, beam-to-column bolted connections can contribute 34–88% of the overall frame elastic lateral stiffness for pinned bases and 17–33% for rigid base connections. Frame stability analysis with respect to global frame and column design were performed for the test specimens. Appropriate frame design analysis should be determined to provide a safe and reliable design for light steel frame considering bolted flexible joints and slender cold-formed steel sections.
format Article
author Yeong, Huei Lee
Tan, Cher Siang
Mohammad, Shahrin
author_facet Yeong, Huei Lee
Tan, Cher Siang
Mohammad, Shahrin
author_sort Yeong, Huei Lee
title In-plane sway behaviour of slender cold-formed steel bolted frames
title_short In-plane sway behaviour of slender cold-formed steel bolted frames
title_full In-plane sway behaviour of slender cold-formed steel bolted frames
title_fullStr In-plane sway behaviour of slender cold-formed steel bolted frames
title_full_unstemmed In-plane sway behaviour of slender cold-formed steel bolted frames
title_sort in-plane sway behaviour of slender cold-formed steel bolted frames
publisher Elsevier
publishDate 2017
url http://eprints.utm.my/id/eprint/66500/
http://dx.doi.org/10.1016/j.tws.2017.01.024
_version_ 1643655810337734656