A review on windcatcher for passive cooling and natural ventilation in buildings, part 1: indoor air quality and thermal comfort assessment

The most prominent challenge in 21th century is global warming which seriously threats the mankind. Building sector with 40% of global energy consumption and GHG emission play a key role in this threat. In this regard, the impact of cooling systems cannot be ignored where along with ventilation and...

Full description

Saved in:
Bibliographic Details
Main Authors: Jomehzadeh, Fatemeh, Nejat, Payam, John, Kaiser Calautit, Mohd. Yusof, Mohd. Badruddin, Shaikh Salim, Sheikh Ahmad Zaki, Ben, Richard Hughes, Muhammad Yazid, Muhammad Noor Afiq Witri
Format: Article
Published: Elsevier 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/66493/
https://doi.org/10.1016/j.rser.2016.11.254
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.66493
record_format eprints
spelling my.utm.664932017-10-03T13:24:27Z http://eprints.utm.my/id/eprint/66493/ A review on windcatcher for passive cooling and natural ventilation in buildings, part 1: indoor air quality and thermal comfort assessment Jomehzadeh, Fatemeh Nejat, Payam John, Kaiser Calautit Mohd. Yusof, Mohd. Badruddin Shaikh Salim, Sheikh Ahmad Zaki Ben, Richard Hughes Muhammad Yazid, Muhammad Noor Afiq Witri TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery T Technology The most prominent challenge in 21th century is global warming which seriously threats the mankind. Building sector with 40% of global energy consumption and GHG emission play a key role in this threat. In this regard, the impact of cooling systems cannot be ignored where along with ventilation and heating systems totally account for 60% of energy consumed in buildings. Passive cooling systems can be a promising alternative to reduce energy consumption. One of the oldest passive cooling system that is still being used today is windcatcher. By manipulating pressure differences and the buoyancy effect, an adequate level of ventilation in buildings can be provided by windcatchers. Since most of the previous windcatcher studies assessed the design characteristics, the current investigation focused on the indoor air quality (IAQ) and thermal comfort aspects. The review details and compares the different theoretical and experimental methods employed by researchers in different case studies to assess the IAQ and thermal comfort. It was found that most IAQ studies were conducted in the UK using CFD and experimental techniques. Previous studies assessed IAQ based on several parameters such as air flow rate, air change rate, CO2 concentration, air change effectiveness and mean age of air. The findings of the studies revealed that satisfactory IAQ were generally achieved using the windcatcher. On the other hand, thermal comfort studies of windcatchers were mainly conducted in hot climates such as in the Middle East. In addition to night ventilation, the review also looked into the different types of cooling methods incorporated with windcatchers such as evaporative cooling, earth to air heat exchangers (EAHE) and heat transfer devices (HTD). Night ventilation was found to be effective in temperate and cold conditions while additional cooling using evaporative cooling, EAHE and HTD were found to be necessary in hot climates. Elsevier 2017-01-04 Article PeerReviewed Jomehzadeh, Fatemeh and Nejat, Payam and John, Kaiser Calautit and Mohd. Yusof, Mohd. Badruddin and Shaikh Salim, Sheikh Ahmad Zaki and Ben, Richard Hughes and Muhammad Yazid, Muhammad Noor Afiq Witri (2017) A review on windcatcher for passive cooling and natural ventilation in buildings, part 1: indoor air quality and thermal comfort assessment. Renewable and Sustainable Energy Reviews, 70 . pp. 736-756. ISSN 1364-0321 https://doi.org/10.1016/j.rser.2016.11.254 DOI:10.1016/j.rser.2016.11.254
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TA Engineering (General). Civil engineering (General)
TJ Mechanical engineering and machinery
T Technology
spellingShingle TA Engineering (General). Civil engineering (General)
TJ Mechanical engineering and machinery
T Technology
Jomehzadeh, Fatemeh
Nejat, Payam
John, Kaiser Calautit
Mohd. Yusof, Mohd. Badruddin
Shaikh Salim, Sheikh Ahmad Zaki
Ben, Richard Hughes
Muhammad Yazid, Muhammad Noor Afiq Witri
A review on windcatcher for passive cooling and natural ventilation in buildings, part 1: indoor air quality and thermal comfort assessment
description The most prominent challenge in 21th century is global warming which seriously threats the mankind. Building sector with 40% of global energy consumption and GHG emission play a key role in this threat. In this regard, the impact of cooling systems cannot be ignored where along with ventilation and heating systems totally account for 60% of energy consumed in buildings. Passive cooling systems can be a promising alternative to reduce energy consumption. One of the oldest passive cooling system that is still being used today is windcatcher. By manipulating pressure differences and the buoyancy effect, an adequate level of ventilation in buildings can be provided by windcatchers. Since most of the previous windcatcher studies assessed the design characteristics, the current investigation focused on the indoor air quality (IAQ) and thermal comfort aspects. The review details and compares the different theoretical and experimental methods employed by researchers in different case studies to assess the IAQ and thermal comfort. It was found that most IAQ studies were conducted in the UK using CFD and experimental techniques. Previous studies assessed IAQ based on several parameters such as air flow rate, air change rate, CO2 concentration, air change effectiveness and mean age of air. The findings of the studies revealed that satisfactory IAQ were generally achieved using the windcatcher. On the other hand, thermal comfort studies of windcatchers were mainly conducted in hot climates such as in the Middle East. In addition to night ventilation, the review also looked into the different types of cooling methods incorporated with windcatchers such as evaporative cooling, earth to air heat exchangers (EAHE) and heat transfer devices (HTD). Night ventilation was found to be effective in temperate and cold conditions while additional cooling using evaporative cooling, EAHE and HTD were found to be necessary in hot climates.
format Article
author Jomehzadeh, Fatemeh
Nejat, Payam
John, Kaiser Calautit
Mohd. Yusof, Mohd. Badruddin
Shaikh Salim, Sheikh Ahmad Zaki
Ben, Richard Hughes
Muhammad Yazid, Muhammad Noor Afiq Witri
author_facet Jomehzadeh, Fatemeh
Nejat, Payam
John, Kaiser Calautit
Mohd. Yusof, Mohd. Badruddin
Shaikh Salim, Sheikh Ahmad Zaki
Ben, Richard Hughes
Muhammad Yazid, Muhammad Noor Afiq Witri
author_sort Jomehzadeh, Fatemeh
title A review on windcatcher for passive cooling and natural ventilation in buildings, part 1: indoor air quality and thermal comfort assessment
title_short A review on windcatcher for passive cooling and natural ventilation in buildings, part 1: indoor air quality and thermal comfort assessment
title_full A review on windcatcher for passive cooling and natural ventilation in buildings, part 1: indoor air quality and thermal comfort assessment
title_fullStr A review on windcatcher for passive cooling and natural ventilation in buildings, part 1: indoor air quality and thermal comfort assessment
title_full_unstemmed A review on windcatcher for passive cooling and natural ventilation in buildings, part 1: indoor air quality and thermal comfort assessment
title_sort review on windcatcher for passive cooling and natural ventilation in buildings, part 1: indoor air quality and thermal comfort assessment
publisher Elsevier
publishDate 2017
url http://eprints.utm.my/id/eprint/66493/
https://doi.org/10.1016/j.rser.2016.11.254
_version_ 1643655808294060032
score 13.18916