The effect of cannulated screw placement angle in the management of femoral neck fracture

Fixation with cannulated screw was widely accepted for management of femoral neck fracture. However, the angle of placement cannulated screw for management of femoral neck fracture still controversial. The present study aims to investigate the mechanical behavior of the cannulated screws with two di...

Full description

Saved in:
Bibliographic Details
Main Authors: Ishak, Muhammad Farhan, Abdul Kadir, Mohammed Rafiq, Harun, Habibollah, Abdul Rahman, Shaifuzain
Format: Article
Published: Trans Tech Publication 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/62871/
http://dx.doi.org/10.4028/www.scientific.net/AMR.845.216
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.62871
record_format eprints
spelling my.utm.628712017-06-19T00:55:20Z http://eprints.utm.my/id/eprint/62871/ The effect of cannulated screw placement angle in the management of femoral neck fracture Ishak, Muhammad Farhan Abdul Kadir, Mohammed Rafiq Harun, Habibollah Abdul Rahman, Shaifuzain QH Natural history Fixation with cannulated screw was widely accepted for management of femoral neck fracture. However, the angle of placement cannulated screw for management of femoral neck fracture still controversial. The present study aims to investigate the mechanical behavior of the cannulated screws with two different angles of placements which are 135o and 150o in inverted triangular configuration for management of femoral neck fracture via finite element method. Therefore, the 3D model of a proximal femur consist of femoral neck fracture was constructed from CT data images using medical image processing software. The von Mises stress distributions on the cannulated screws were compared between each screw angle placement. The result showed that the cannulated screws in inverted triangle with 135o of placement angle have better stress distributions than 150o placement angle. Trans Tech Publication 2014 Article PeerReviewed Ishak, Muhammad Farhan and Abdul Kadir, Mohammed Rafiq and Harun, Habibollah and Abdul Rahman, Shaifuzain (2014) The effect of cannulated screw placement angle in the management of femoral neck fracture. Advanced Materials Research, 845 . pp. 216-220. ISSN 1022-6680 http://dx.doi.org/10.4028/www.scientific.net/AMR.845.216 DOI:10.4028/www.scientific.net/AMR.845.216
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic QH Natural history
spellingShingle QH Natural history
Ishak, Muhammad Farhan
Abdul Kadir, Mohammed Rafiq
Harun, Habibollah
Abdul Rahman, Shaifuzain
The effect of cannulated screw placement angle in the management of femoral neck fracture
description Fixation with cannulated screw was widely accepted for management of femoral neck fracture. However, the angle of placement cannulated screw for management of femoral neck fracture still controversial. The present study aims to investigate the mechanical behavior of the cannulated screws with two different angles of placements which are 135o and 150o in inverted triangular configuration for management of femoral neck fracture via finite element method. Therefore, the 3D model of a proximal femur consist of femoral neck fracture was constructed from CT data images using medical image processing software. The von Mises stress distributions on the cannulated screws were compared between each screw angle placement. The result showed that the cannulated screws in inverted triangle with 135o of placement angle have better stress distributions than 150o placement angle.
format Article
author Ishak, Muhammad Farhan
Abdul Kadir, Mohammed Rafiq
Harun, Habibollah
Abdul Rahman, Shaifuzain
author_facet Ishak, Muhammad Farhan
Abdul Kadir, Mohammed Rafiq
Harun, Habibollah
Abdul Rahman, Shaifuzain
author_sort Ishak, Muhammad Farhan
title The effect of cannulated screw placement angle in the management of femoral neck fracture
title_short The effect of cannulated screw placement angle in the management of femoral neck fracture
title_full The effect of cannulated screw placement angle in the management of femoral neck fracture
title_fullStr The effect of cannulated screw placement angle in the management of femoral neck fracture
title_full_unstemmed The effect of cannulated screw placement angle in the management of femoral neck fracture
title_sort effect of cannulated screw placement angle in the management of femoral neck fracture
publisher Trans Tech Publication
publishDate 2014
url http://eprints.utm.my/id/eprint/62871/
http://dx.doi.org/10.4028/www.scientific.net/AMR.845.216
_version_ 1643655547223801856
score 13.159267