Tapered plastic optical fiber coated with single wall carbon nanotubes polyethylene oxide composite for measurement of uric acid concentration

Purpose - A simple tapered plastic optical fiber (POF) sensor is proposed and demonstrated for measurement of uric acid concentrations in de-ionized water. The paper aims to discuss these issues. Design/methodology/approach - The sensor operates based on intensity modulation technique as the tapered...

Full description

Saved in:
Bibliographic Details
Main Authors: Batumalay, Malathy, Ahmad, Fauzan, Lokman, Asiah, Jasim, A. A., Harun, Sulaiman Wadi, Ahmad, H.
Format: Article
Published: Emerald Group Publishing 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/62809/
http://dx.doi.org/10.1108/SR-09-2012-699
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.62809
record_format eprints
spelling my.utm.628092017-06-19T00:13:19Z http://eprints.utm.my/id/eprint/62809/ Tapered plastic optical fiber coated with single wall carbon nanotubes polyethylene oxide composite for measurement of uric acid concentration Batumalay, Malathy Ahmad, Fauzan Lokman, Asiah Jasim, A. A. Harun, Sulaiman Wadi Ahmad, H. TA Engineering (General). Civil engineering (General) Purpose - A simple tapered plastic optical fiber (POF) sensor is proposed and demonstrated for measurement of uric acid concentrations in de-ionized water. The paper aims to discuss these issues. Design/methodology/approach - The sensor operates based on intensity modulation technique as the tapered POF probe which was coated by a single walled carbon nonotubes polyethylene oxide (SWCNT-PEO) composite is immersed into the uric acid solution. The probe was fabricated using an etching method and has a waist diameter of 0.46 mm and tapering length of 10 mm. Findings - As the concentration varies from 0 to 500 ppm, the output voltage of the sensor increases linearly from 6.13 to 7.35 mV with a sensitivity of 0.0023 mV/% and a linearity of more than 97.20 percent. The SWCNT-PEO composite coating increases the sensitivity of the proposed sensor due to the effective cladding refractive index, which increases with the coating and thus allows more light to be transmitted from the tapered fiber. Originality/value - This is the first demonstration of the tapered POF sensor for measurement of uric acid concentrations in de-ionized water. Emerald Group Publishing 2014 Article PeerReviewed Batumalay, Malathy and Ahmad, Fauzan and Lokman, Asiah and Jasim, A. A. and Harun, Sulaiman Wadi and Ahmad, H. (2014) Tapered plastic optical fiber coated with single wall carbon nanotubes polyethylene oxide composite for measurement of uric acid concentration. Sensor Review, 34 (1). pp. 75-79. ISSN 0260-2288 http://dx.doi.org/10.1108/SR-09-2012-699 DOI:10.1108/SR-09-2012-699
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Batumalay, Malathy
Ahmad, Fauzan
Lokman, Asiah
Jasim, A. A.
Harun, Sulaiman Wadi
Ahmad, H.
Tapered plastic optical fiber coated with single wall carbon nanotubes polyethylene oxide composite for measurement of uric acid concentration
description Purpose - A simple tapered plastic optical fiber (POF) sensor is proposed and demonstrated for measurement of uric acid concentrations in de-ionized water. The paper aims to discuss these issues. Design/methodology/approach - The sensor operates based on intensity modulation technique as the tapered POF probe which was coated by a single walled carbon nonotubes polyethylene oxide (SWCNT-PEO) composite is immersed into the uric acid solution. The probe was fabricated using an etching method and has a waist diameter of 0.46 mm and tapering length of 10 mm. Findings - As the concentration varies from 0 to 500 ppm, the output voltage of the sensor increases linearly from 6.13 to 7.35 mV with a sensitivity of 0.0023 mV/% and a linearity of more than 97.20 percent. The SWCNT-PEO composite coating increases the sensitivity of the proposed sensor due to the effective cladding refractive index, which increases with the coating and thus allows more light to be transmitted from the tapered fiber. Originality/value - This is the first demonstration of the tapered POF sensor for measurement of uric acid concentrations in de-ionized water.
format Article
author Batumalay, Malathy
Ahmad, Fauzan
Lokman, Asiah
Jasim, A. A.
Harun, Sulaiman Wadi
Ahmad, H.
author_facet Batumalay, Malathy
Ahmad, Fauzan
Lokman, Asiah
Jasim, A. A.
Harun, Sulaiman Wadi
Ahmad, H.
author_sort Batumalay, Malathy
title Tapered plastic optical fiber coated with single wall carbon nanotubes polyethylene oxide composite for measurement of uric acid concentration
title_short Tapered plastic optical fiber coated with single wall carbon nanotubes polyethylene oxide composite for measurement of uric acid concentration
title_full Tapered plastic optical fiber coated with single wall carbon nanotubes polyethylene oxide composite for measurement of uric acid concentration
title_fullStr Tapered plastic optical fiber coated with single wall carbon nanotubes polyethylene oxide composite for measurement of uric acid concentration
title_full_unstemmed Tapered plastic optical fiber coated with single wall carbon nanotubes polyethylene oxide composite for measurement of uric acid concentration
title_sort tapered plastic optical fiber coated with single wall carbon nanotubes polyethylene oxide composite for measurement of uric acid concentration
publisher Emerald Group Publishing
publishDate 2014
url http://eprints.utm.my/id/eprint/62809/
http://dx.doi.org/10.1108/SR-09-2012-699
_version_ 1643655529240723456
score 13.214268