Small gas component detection using ultrasonic transmission-mode tomography system
This paper presents the development of an ultrasonic transmission-mode tomography system for the detection of small gas components by using higher frequency ultrasonic transducers. The selection of the transducer is important and must be suitable to the application design. Consideration on the natur...
Saved in:
Main Authors: | , , , , , , , , , , |
---|---|
Format: | Article |
Published: |
Penerbit UTM Press
2014
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/62607/ http://dx.doi.org/10.11113/jt.v69.3302 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.62607 |
---|---|
record_format |
eprints |
spelling |
my.utm.626072017-06-18T08:36:11Z http://eprints.utm.my/id/eprint/62607/ Small gas component detection using ultrasonic transmission-mode tomography system Nor Ayob, Nor Muzakkir Pusppanathan, Muhammad Jaysuman Abdul Rahim, Ruzairi Rahiman, Mohd. Hafiz Fazalul Mohd Yunus, Fazlul Rahman Zakaria, Zulkarnay Goh, Chiew Loon Buyamin, Salinda Ahmad, Nasarudin Md. Yunos, Yusri Abdul Wahab, Norhaliza TK Electrical engineering. Electronics Nuclear engineering This paper presents the development of an ultrasonic transmission-mode tomography system for the detection of small gas components by using higher frequency ultrasonic transducers. The selection of the transducer is important and must be suitable to the application design. Consideration on the natural limitation of ultrasonic wave is also noted as the higher the frequency of the ultrasonic transducer, the better the sensitivity but lower penetration depth. 16-pairs of these ultrasonic sensors are installed and fixed inside a sensor jig which is designed to hold all the sensors while providing support for optimum angle sensor placement. The sensor jig is also mounted on the circumference of a vertical column which will be used as the investigated process vessel. The developments presented also include the non-invasive fabrication techniques, the electronic measurement circuits, image reconstruction technique, and finally on the imaging results of the proposed system. Penerbit UTM Press 2014 Article PeerReviewed Nor Ayob, Nor Muzakkir and Pusppanathan, Muhammad Jaysuman and Abdul Rahim, Ruzairi and Rahiman, Mohd. Hafiz Fazalul and Mohd Yunus, Fazlul Rahman and Zakaria, Zulkarnay and Goh, Chiew Loon and Buyamin, Salinda and Ahmad, Nasarudin and Md. Yunos, Yusri and Abdul Wahab, Norhaliza (2014) Small gas component detection using ultrasonic transmission-mode tomography system. Jurnal Teknologi (Sciences and Engineering), 69 (8). pp. 95-100. ISSN 0127-9696 http://dx.doi.org/10.11113/jt.v69.3302 DOI:10.11113/jt.v69.3302 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Nor Ayob, Nor Muzakkir Pusppanathan, Muhammad Jaysuman Abdul Rahim, Ruzairi Rahiman, Mohd. Hafiz Fazalul Mohd Yunus, Fazlul Rahman Zakaria, Zulkarnay Goh, Chiew Loon Buyamin, Salinda Ahmad, Nasarudin Md. Yunos, Yusri Abdul Wahab, Norhaliza Small gas component detection using ultrasonic transmission-mode tomography system |
description |
This paper presents the development of an ultrasonic transmission-mode tomography system for the detection of small gas components by using higher frequency ultrasonic transducers. The selection of the transducer is important and must be suitable to the application design. Consideration on the natural limitation of ultrasonic wave is also noted as the higher the frequency of the ultrasonic transducer, the better the sensitivity but lower penetration depth. 16-pairs of these ultrasonic sensors are installed and fixed inside a sensor jig which is designed to hold all the sensors while providing support for optimum angle sensor placement. The sensor jig is also mounted on the circumference of a vertical column which will be used as the investigated process vessel. The developments presented also include the non-invasive fabrication techniques, the electronic measurement circuits, image reconstruction technique, and finally on the imaging results of the proposed system. |
format |
Article |
author |
Nor Ayob, Nor Muzakkir Pusppanathan, Muhammad Jaysuman Abdul Rahim, Ruzairi Rahiman, Mohd. Hafiz Fazalul Mohd Yunus, Fazlul Rahman Zakaria, Zulkarnay Goh, Chiew Loon Buyamin, Salinda Ahmad, Nasarudin Md. Yunos, Yusri Abdul Wahab, Norhaliza |
author_facet |
Nor Ayob, Nor Muzakkir Pusppanathan, Muhammad Jaysuman Abdul Rahim, Ruzairi Rahiman, Mohd. Hafiz Fazalul Mohd Yunus, Fazlul Rahman Zakaria, Zulkarnay Goh, Chiew Loon Buyamin, Salinda Ahmad, Nasarudin Md. Yunos, Yusri Abdul Wahab, Norhaliza |
author_sort |
Nor Ayob, Nor Muzakkir |
title |
Small gas component detection using ultrasonic transmission-mode tomography system |
title_short |
Small gas component detection using ultrasonic transmission-mode tomography system |
title_full |
Small gas component detection using ultrasonic transmission-mode tomography system |
title_fullStr |
Small gas component detection using ultrasonic transmission-mode tomography system |
title_full_unstemmed |
Small gas component detection using ultrasonic transmission-mode tomography system |
title_sort |
small gas component detection using ultrasonic transmission-mode tomography system |
publisher |
Penerbit UTM Press |
publishDate |
2014 |
url |
http://eprints.utm.my/id/eprint/62607/ http://dx.doi.org/10.11113/jt.v69.3302 |
_version_ |
1643655470065385472 |
score |
13.209306 |