Small gas component detection using ultrasonic transmission-mode tomography system

This paper presents the development of an ultrasonic transmission-mode tomography system for the detection of small gas components by using higher frequency ultrasonic transducers. The selection of the transducer is important and must be suitable to the application design. Consideration on the natur...

Full description

Saved in:
Bibliographic Details
Main Authors: Nor Ayob, Nor Muzakkir, Pusppanathan, Muhammad Jaysuman, Abdul Rahim, Ruzairi, Rahiman, Mohd. Hafiz Fazalul, Mohd Yunus, Fazlul Rahman, Zakaria, Zulkarnay, Goh, Chiew Loon, Buyamin, Salinda, Ahmad, Nasarudin, Md. Yunos, Yusri, Abdul Wahab, Norhaliza
Format: Article
Published: Penerbit UTM Press 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/62607/
http://dx.doi.org/10.11113/jt.v69.3302
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.62607
record_format eprints
spelling my.utm.626072017-06-18T08:36:11Z http://eprints.utm.my/id/eprint/62607/ Small gas component detection using ultrasonic transmission-mode tomography system Nor Ayob, Nor Muzakkir Pusppanathan, Muhammad Jaysuman Abdul Rahim, Ruzairi Rahiman, Mohd. Hafiz Fazalul Mohd Yunus, Fazlul Rahman Zakaria, Zulkarnay Goh, Chiew Loon Buyamin, Salinda Ahmad, Nasarudin Md. Yunos, Yusri Abdul Wahab, Norhaliza TK Electrical engineering. Electronics Nuclear engineering This paper presents the development of an ultrasonic transmission-mode tomography system for the detection of small gas components by using higher frequency ultrasonic transducers. The selection of the transducer is important and must be suitable to the application design. Consideration on the natural limitation of ultrasonic wave is also noted as the higher the frequency of the ultrasonic transducer, the better the sensitivity but lower penetration depth. 16-pairs of these ultrasonic sensors are installed and fixed inside a sensor jig which is designed to hold all the sensors while providing support for optimum angle sensor placement. The sensor jig is also mounted on the circumference of a vertical column which will be used as the investigated process vessel. The developments presented also include the non-invasive fabrication techniques, the electronic measurement circuits, image reconstruction technique, and finally on the imaging results of the proposed system. Penerbit UTM Press 2014 Article PeerReviewed Nor Ayob, Nor Muzakkir and Pusppanathan, Muhammad Jaysuman and Abdul Rahim, Ruzairi and Rahiman, Mohd. Hafiz Fazalul and Mohd Yunus, Fazlul Rahman and Zakaria, Zulkarnay and Goh, Chiew Loon and Buyamin, Salinda and Ahmad, Nasarudin and Md. Yunos, Yusri and Abdul Wahab, Norhaliza (2014) Small gas component detection using ultrasonic transmission-mode tomography system. Jurnal Teknologi (Sciences and Engineering), 69 (8). pp. 95-100. ISSN 0127-9696 http://dx.doi.org/10.11113/jt.v69.3302 DOI:10.11113/jt.v69.3302
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Nor Ayob, Nor Muzakkir
Pusppanathan, Muhammad Jaysuman
Abdul Rahim, Ruzairi
Rahiman, Mohd. Hafiz Fazalul
Mohd Yunus, Fazlul Rahman
Zakaria, Zulkarnay
Goh, Chiew Loon
Buyamin, Salinda
Ahmad, Nasarudin
Md. Yunos, Yusri
Abdul Wahab, Norhaliza
Small gas component detection using ultrasonic transmission-mode tomography system
description This paper presents the development of an ultrasonic transmission-mode tomography system for the detection of small gas components by using higher frequency ultrasonic transducers. The selection of the transducer is important and must be suitable to the application design. Consideration on the natural limitation of ultrasonic wave is also noted as the higher the frequency of the ultrasonic transducer, the better the sensitivity but lower penetration depth. 16-pairs of these ultrasonic sensors are installed and fixed inside a sensor jig which is designed to hold all the sensors while providing support for optimum angle sensor placement. The sensor jig is also mounted on the circumference of a vertical column which will be used as the investigated process vessel. The developments presented also include the non-invasive fabrication techniques, the electronic measurement circuits, image reconstruction technique, and finally on the imaging results of the proposed system.
format Article
author Nor Ayob, Nor Muzakkir
Pusppanathan, Muhammad Jaysuman
Abdul Rahim, Ruzairi
Rahiman, Mohd. Hafiz Fazalul
Mohd Yunus, Fazlul Rahman
Zakaria, Zulkarnay
Goh, Chiew Loon
Buyamin, Salinda
Ahmad, Nasarudin
Md. Yunos, Yusri
Abdul Wahab, Norhaliza
author_facet Nor Ayob, Nor Muzakkir
Pusppanathan, Muhammad Jaysuman
Abdul Rahim, Ruzairi
Rahiman, Mohd. Hafiz Fazalul
Mohd Yunus, Fazlul Rahman
Zakaria, Zulkarnay
Goh, Chiew Loon
Buyamin, Salinda
Ahmad, Nasarudin
Md. Yunos, Yusri
Abdul Wahab, Norhaliza
author_sort Nor Ayob, Nor Muzakkir
title Small gas component detection using ultrasonic transmission-mode tomography system
title_short Small gas component detection using ultrasonic transmission-mode tomography system
title_full Small gas component detection using ultrasonic transmission-mode tomography system
title_fullStr Small gas component detection using ultrasonic transmission-mode tomography system
title_full_unstemmed Small gas component detection using ultrasonic transmission-mode tomography system
title_sort small gas component detection using ultrasonic transmission-mode tomography system
publisher Penerbit UTM Press
publishDate 2014
url http://eprints.utm.my/id/eprint/62607/
http://dx.doi.org/10.11113/jt.v69.3302
_version_ 1643655470065385472
score 13.209306