Experimental and analytical study of various shear connectors used for cold-formed steel-ferrocement composite beam

This work presents the experimental tests carried out to evaluate the behaviour of different types of shear connectors proposed for cold formed steel (CFS) section integrated with ferrocement slab as potential used for composite beam. Ten push-out test specimens of cold-formed steel lipped channel s...

Full description

Saved in:
Bibliographic Details
Main Authors: Saggaff, Anis, Alhajri, Talal, Md. Tahir, Mahmood, Alenezi, Khaled, Cher, Siang Tan, Sulaiman, Arizu, Muhammad Lawan, Mustapha, Mohamad Ragaee, Mohamad Ragaee
Format: Conference or Workshop Item
Published: 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/61987/
https://eventegg.com/icamet-2014/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.61987
record_format eprints
spelling my.utm.619872017-09-11T07:49:46Z http://eprints.utm.my/id/eprint/61987/ Experimental and analytical study of various shear connectors used for cold-formed steel-ferrocement composite beam Saggaff, Anis Alhajri, Talal Md. Tahir, Mahmood Alenezi, Khaled Cher, Siang Tan Sulaiman, Arizu Muhammad Lawan, Mustapha Mohamad Ragaee, Mohamad Ragaee TA Engineering (General). Civil engineering (General) This work presents the experimental tests carried out to evaluate the behaviour of different types of shear connectors proposed for cold formed steel (CFS) section integrated with ferrocement slab as potential used for composite beam. Ten push-out test specimens of cold-formed steel lipped channel sections connected with ferrocement slab were tested. Three types of shear connectors were studied comprised of bolts, self-drilling-screw and bar angle. The connection behavior is analysed in terms of its load-slip relationship and the failure mode. The parametric studies were performed to investigate the effect on the shear connector’s capacity by varying the number of layers of wire mesh used in ferrocement slab and types of shear connector used. A theoretical analysis (Eurocode 4) were carried out to verify the experiment results. The results show that the experimental and theoretical proved to have good agreement with each other. 2014 Conference or Workshop Item PeerReviewed Saggaff, Anis and Alhajri, Talal and Md. Tahir, Mahmood and Alenezi, Khaled and Cher, Siang Tan and Sulaiman, Arizu and Muhammad Lawan, Mustapha and Mohamad Ragaee, Mohamad Ragaee (2014) Experimental and analytical study of various shear connectors used for cold-formed steel-ferrocement composite beam. In: International Conference on Advanced Material Engineering & Technology 2014, 5-6 Dec, 2014, Vietnam. https://eventegg.com/icamet-2014/
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Saggaff, Anis
Alhajri, Talal
Md. Tahir, Mahmood
Alenezi, Khaled
Cher, Siang Tan
Sulaiman, Arizu
Muhammad Lawan, Mustapha
Mohamad Ragaee, Mohamad Ragaee
Experimental and analytical study of various shear connectors used for cold-formed steel-ferrocement composite beam
description This work presents the experimental tests carried out to evaluate the behaviour of different types of shear connectors proposed for cold formed steel (CFS) section integrated with ferrocement slab as potential used for composite beam. Ten push-out test specimens of cold-formed steel lipped channel sections connected with ferrocement slab were tested. Three types of shear connectors were studied comprised of bolts, self-drilling-screw and bar angle. The connection behavior is analysed in terms of its load-slip relationship and the failure mode. The parametric studies were performed to investigate the effect on the shear connector’s capacity by varying the number of layers of wire mesh used in ferrocement slab and types of shear connector used. A theoretical analysis (Eurocode 4) were carried out to verify the experiment results. The results show that the experimental and theoretical proved to have good agreement with each other.
format Conference or Workshop Item
author Saggaff, Anis
Alhajri, Talal
Md. Tahir, Mahmood
Alenezi, Khaled
Cher, Siang Tan
Sulaiman, Arizu
Muhammad Lawan, Mustapha
Mohamad Ragaee, Mohamad Ragaee
author_facet Saggaff, Anis
Alhajri, Talal
Md. Tahir, Mahmood
Alenezi, Khaled
Cher, Siang Tan
Sulaiman, Arizu
Muhammad Lawan, Mustapha
Mohamad Ragaee, Mohamad Ragaee
author_sort Saggaff, Anis
title Experimental and analytical study of various shear connectors used for cold-formed steel-ferrocement composite beam
title_short Experimental and analytical study of various shear connectors used for cold-formed steel-ferrocement composite beam
title_full Experimental and analytical study of various shear connectors used for cold-formed steel-ferrocement composite beam
title_fullStr Experimental and analytical study of various shear connectors used for cold-formed steel-ferrocement composite beam
title_full_unstemmed Experimental and analytical study of various shear connectors used for cold-formed steel-ferrocement composite beam
title_sort experimental and analytical study of various shear connectors used for cold-formed steel-ferrocement composite beam
publishDate 2014
url http://eprints.utm.my/id/eprint/61987/
https://eventegg.com/icamet-2014/
_version_ 1643655296076218368
score 13.18916