Particulate emission size distribution from palm oil mill boiler

A study on the particulate emission size distribution from five different palm oil mills with boiler steam capacity ranging from 17,000 to 35,000kg/hr was investigated and is reported in this paper. The mills are all equipped with a multi-cyclones particulate arrestor. The particulate sample was col...

Full description

Saved in:
Bibliographic Details
Main Authors: Jamian, Nor Ruwaida, Mohd. Yusof, Mohd. Rashid, Mohd. Muzi, Syahirah
Format: Conference or Workshop Item
Language:English
Published: 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/61234/1/MohdRashidMohd2015_Particulateemissionsizedistributionfrompalmoil.pdf
http://eprints.utm.my/id/eprint/61234/
Tags: Add Tag
No Tags, Be the first to tag this record!
Be the first to leave a comment!
You must be logged in first