Least mean square as error correction method of multi-port reflectometer for microwave imaging of human head

This article present an error correction of a wideband multi-port reflectometer for microwave imaging application of the human head using Least Means Square (LMS) technique. The configuration of the wideband reflectometer is formed by passive circuits, which are four couplers and two power dividers....

Full description

Saved in:
Bibliographic Details
Main Authors: Yob, R. C., Seman, N., Yusof, K. H.
Format: Conference or Workshop Item
Published: 2013
Subjects:
Online Access:http://eprints.utm.my/id/eprint/59356/
http://dx.doi.org/10.1109/SCOReD.2013.7002604
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.59356
record_format eprints
spelling my.utm.593562021-12-15T01:47:44Z http://eprints.utm.my/id/eprint/59356/ Least mean square as error correction method of multi-port reflectometer for microwave imaging of human head Yob, R. C. Seman, N. Yusof, K. H. TK Electrical engineering. Electronics Nuclear engineering This article present an error correction of a wideband multi-port reflectometer for microwave imaging application of the human head using Least Means Square (LMS) technique. The configuration of the wideband reflectometer is formed by passive circuits, which are four couplers and two power dividers. The analysis of the proposed error correction is done through the mathematical equation calculation based on the LMS technique, which accomplished via the use of the Agilent's Advance Design Systems (ADS) software. Through the application of this error correction procedure, any imperfect characteristics of the wideband reflectometer have been removed. A number of loads have been used as the Device Under Tests (DUTs). The corrected reflection coefficients are comparable with the theoretical values. The good performance of the corrected reflection coefficients has been achieved when the LMS is applied. 2013-01-06 Conference or Workshop Item PeerReviewed Yob, R. C. and Seman, N. and Yusof, K. H. (2013) Least mean square as error correction method of multi-port reflectometer for microwave imaging of human head. In: 11th IEEE Student Conference on Research and Development, SCOReD 2013, 16 December 2013 - 17 December 2013, Putrajaya, Malaysia. http://dx.doi.org/10.1109/SCOReD.2013.7002604
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Yob, R. C.
Seman, N.
Yusof, K. H.
Least mean square as error correction method of multi-port reflectometer for microwave imaging of human head
description This article present an error correction of a wideband multi-port reflectometer for microwave imaging application of the human head using Least Means Square (LMS) technique. The configuration of the wideband reflectometer is formed by passive circuits, which are four couplers and two power dividers. The analysis of the proposed error correction is done through the mathematical equation calculation based on the LMS technique, which accomplished via the use of the Agilent's Advance Design Systems (ADS) software. Through the application of this error correction procedure, any imperfect characteristics of the wideband reflectometer have been removed. A number of loads have been used as the Device Under Tests (DUTs). The corrected reflection coefficients are comparable with the theoretical values. The good performance of the corrected reflection coefficients has been achieved when the LMS is applied.
format Conference or Workshop Item
author Yob, R. C.
Seman, N.
Yusof, K. H.
author_facet Yob, R. C.
Seman, N.
Yusof, K. H.
author_sort Yob, R. C.
title Least mean square as error correction method of multi-port reflectometer for microwave imaging of human head
title_short Least mean square as error correction method of multi-port reflectometer for microwave imaging of human head
title_full Least mean square as error correction method of multi-port reflectometer for microwave imaging of human head
title_fullStr Least mean square as error correction method of multi-port reflectometer for microwave imaging of human head
title_full_unstemmed Least mean square as error correction method of multi-port reflectometer for microwave imaging of human head
title_sort least mean square as error correction method of multi-port reflectometer for microwave imaging of human head
publishDate 2013
url http://eprints.utm.my/id/eprint/59356/
http://dx.doi.org/10.1109/SCOReD.2013.7002604
_version_ 1720436907921375232
score 13.209306