Investigation of the effect of inlet radius on the response time of a transmission type ozone sensor

The effect of inlet radius of a transmission type optical gas cell on its response time is reported. Six gas cells of varying lengths, and internal radius of 0.32cm were considered at first and then other internal diameters were also investigated afterwards. The effect of inlet radius is easily disc...

Full description

Saved in:
Bibliographic Details
Main Authors: David, M., Marcus, T. C. E., Yaacob, M., Hussin, N., Salim, M. R., Ibrahim, M. H., Idrus, S. M., Azmi, A. I., Ngajikin, N. H.
Format: Conference or Workshop Item
Published: 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/59339/
http://dx.doi.org/10.1109/APACE.2014.7043712
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.59339
record_format eprints
spelling my.utm.593392021-12-15T02:49:59Z http://eprints.utm.my/id/eprint/59339/ Investigation of the effect of inlet radius on the response time of a transmission type ozone sensor David, M. Marcus, T. C. E. Yaacob, M. Hussin, N. Salim, M. R. Ibrahim, M. H. Idrus, S. M. Azmi, A. I. Ngajikin, N. H. TK Electrical engineering. Electronics Nuclear engineering The effect of inlet radius of a transmission type optical gas cell on its response time is reported. Six gas cells of varying lengths, and internal radius of 0.32cm were considered at first and then other internal diameters were also investigated afterwards. The effect of inlet radius is easily discernible at all velocities considered; however it is more pronounced at lower flow rates. At a velocity of 16.79cm/s of ozone gas, and for a target sensing time of ≤ 0.5 seconds; we observed that the inlet radius requirements for gas cells of varying lengths and varying internal diameters is not the same for a specific target sensing speed. The length and the internal radius of a gas cell are proportional to its inlet radius. 2015 Conference or Workshop Item PeerReviewed David, M. and Marcus, T. C. E. and Yaacob, M. and Hussin, N. and Salim, M. R. and Ibrahim, M. H. and Idrus, S. M. and Azmi, A. I. and Ngajikin, N. H. (2015) Investigation of the effect of inlet radius on the response time of a transmission type ozone sensor. In: 2014 6th IEEE Asia-Pacific Conference on Applied Electromagnetics, APACE 2014, 8 - 10 December 2014, Johor Bahru, Malaysia. http://dx.doi.org/10.1109/APACE.2014.7043712
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
David, M.
Marcus, T. C. E.
Yaacob, M.
Hussin, N.
Salim, M. R.
Ibrahim, M. H.
Idrus, S. M.
Azmi, A. I.
Ngajikin, N. H.
Investigation of the effect of inlet radius on the response time of a transmission type ozone sensor
description The effect of inlet radius of a transmission type optical gas cell on its response time is reported. Six gas cells of varying lengths, and internal radius of 0.32cm were considered at first and then other internal diameters were also investigated afterwards. The effect of inlet radius is easily discernible at all velocities considered; however it is more pronounced at lower flow rates. At a velocity of 16.79cm/s of ozone gas, and for a target sensing time of ≤ 0.5 seconds; we observed that the inlet radius requirements for gas cells of varying lengths and varying internal diameters is not the same for a specific target sensing speed. The length and the internal radius of a gas cell are proportional to its inlet radius.
format Conference or Workshop Item
author David, M.
Marcus, T. C. E.
Yaacob, M.
Hussin, N.
Salim, M. R.
Ibrahim, M. H.
Idrus, S. M.
Azmi, A. I.
Ngajikin, N. H.
author_facet David, M.
Marcus, T. C. E.
Yaacob, M.
Hussin, N.
Salim, M. R.
Ibrahim, M. H.
Idrus, S. M.
Azmi, A. I.
Ngajikin, N. H.
author_sort David, M.
title Investigation of the effect of inlet radius on the response time of a transmission type ozone sensor
title_short Investigation of the effect of inlet radius on the response time of a transmission type ozone sensor
title_full Investigation of the effect of inlet radius on the response time of a transmission type ozone sensor
title_fullStr Investigation of the effect of inlet radius on the response time of a transmission type ozone sensor
title_full_unstemmed Investigation of the effect of inlet radius on the response time of a transmission type ozone sensor
title_sort investigation of the effect of inlet radius on the response time of a transmission type ozone sensor
publishDate 2015
url http://eprints.utm.my/id/eprint/59339/
http://dx.doi.org/10.1109/APACE.2014.7043712
_version_ 1720436906598072320
score 13.214268