Investigation of the effect of inlet radius on the response time of a transmission type ozone sensor

The effect of inlet radius of a transmission type optical gas cell on its response time is reported. Six gas cells of varying lengths, and internal radius of 0.32cm were considered at first and then other internal diameters were also investigated afterwards. The effect of inlet radius is easily disc...

全面介绍

Saved in:
书目详细资料
Main Authors: David, M., Marcus, T. C. E., Yaacob, M., Hussin, N., Salim, M. R., Ibrahim, M. H., Idrus, S. M., Azmi, A. I., Ngajikin, N. H.
格式: Conference or Workshop Item
出版: 2015
主题:
在线阅读:http://eprints.utm.my/id/eprint/59339/
http://dx.doi.org/10.1109/APACE.2014.7043712
标签: 添加标签
没有标签, 成为第一个标记此记录!
实物特征
总结:The effect of inlet radius of a transmission type optical gas cell on its response time is reported. Six gas cells of varying lengths, and internal radius of 0.32cm were considered at first and then other internal diameters were also investigated afterwards. The effect of inlet radius is easily discernible at all velocities considered; however it is more pronounced at lower flow rates. At a velocity of 16.79cm/s of ozone gas, and for a target sensing time of ≤ 0.5 seconds; we observed that the inlet radius requirements for gas cells of varying lengths and varying internal diameters is not the same for a specific target sensing speed. The length and the internal radius of a gas cell are proportional to its inlet radius.