Investigation of the effect of inlet radius on the response time of a transmission type ozone sensor

The effect of inlet radius of a transmission type optical gas cell on its response time is reported. Six gas cells of varying lengths, and internal radius of 0.32cm were considered at first and then other internal diameters were also investigated afterwards. The effect of inlet radius is easily disc...

全面介紹

Saved in:
書目詳細資料
Main Authors: David, M., Marcus, T. C. E., Yaacob, M., Hussin, N., Salim, M. R., Ibrahim, M. H., Idrus, S. M., Azmi, A. I., Ngajikin, N. H.
格式: Conference or Workshop Item
出版: 2015
主題:
在線閱讀:http://eprints.utm.my/id/eprint/59339/
http://dx.doi.org/10.1109/APACE.2014.7043712
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
實物特徵
總結:The effect of inlet radius of a transmission type optical gas cell on its response time is reported. Six gas cells of varying lengths, and internal radius of 0.32cm were considered at first and then other internal diameters were also investigated afterwards. The effect of inlet radius is easily discernible at all velocities considered; however it is more pronounced at lower flow rates. At a velocity of 16.79cm/s of ozone gas, and for a target sensing time of ≤ 0.5 seconds; we observed that the inlet radius requirements for gas cells of varying lengths and varying internal diameters is not the same for a specific target sensing speed. The length and the internal radius of a gas cell are proportional to its inlet radius.