Non-invasive process tomography in chemical mixtures - a review

Decades of research, visualizing and monitoring chemical mixtures in the process plant non-invasively plays an important role in making sure that the system produces a high quality product without disturbing the nature of the plant. In this case, process tomography can be applied for the chemical mi...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdul Wahab, Yasmin, Abdul Rahim, Ruzairi, Rahiman, Mohd. Hafiz Fazalul, Ridzuan Aw., Suzanna, Mohd. Yunus, Fazlul Rahman, Goh, Chiew Loon, Abdul Rahim, Herlina, Leow, Pei Ling
Format: Article
Published: Elsevier B.V. 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/58649/
http://dx.doi.org/10.1016/j.snb.2014.12.103
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.58649
record_format eprints
spelling my.utm.586492021-09-12T04:20:39Z http://eprints.utm.my/id/eprint/58649/ Non-invasive process tomography in chemical mixtures - a review Abdul Wahab, Yasmin Abdul Rahim, Ruzairi Rahiman, Mohd. Hafiz Fazalul Ridzuan Aw., Suzanna Mohd. Yunus, Fazlul Rahman Goh, Chiew Loon Abdul Rahim, Herlina Leow, Pei Ling TK Electrical engineering. Electronics Nuclear engineering Decades of research, visualizing and monitoring chemical mixtures in the process plant non-invasively plays an important role in making sure that the system produces a high quality product without disturbing the nature of the plant. In this case, process tomography can be applied for the chemical mixtures. Thus, the objective of this paper is to review the current research on non-invasive process tomography for detecting chemical mixtures based on hard-field and soft-field tomography. The discussion on liquid-liquid, liquid-solid and liquid-gas two-phase flow for every type of non-invasive process tomography is explained in detail. Consequently, non-invasive process tomography has expanded strongly in chemical applications. Finally, potential future research on the chemical mixture based on ERT is addressed. Elsevier B.V. 2015-04 Article PeerReviewed Abdul Wahab, Yasmin and Abdul Rahim, Ruzairi and Rahiman, Mohd. Hafiz Fazalul and Ridzuan Aw., Suzanna and Mohd. Yunus, Fazlul Rahman and Goh, Chiew Loon and Abdul Rahim, Herlina and Leow, Pei Ling (2015) Non-invasive process tomography in chemical mixtures - a review. Sensors and Actuators B: Chemical, 210 . pp. 602-617. ISSN 0925-4005 http://dx.doi.org/10.1016/j.snb.2014.12.103 DOI:10.1016/j.snb.2014.12.103
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Abdul Wahab, Yasmin
Abdul Rahim, Ruzairi
Rahiman, Mohd. Hafiz Fazalul
Ridzuan Aw., Suzanna
Mohd. Yunus, Fazlul Rahman
Goh, Chiew Loon
Abdul Rahim, Herlina
Leow, Pei Ling
Non-invasive process tomography in chemical mixtures - a review
description Decades of research, visualizing and monitoring chemical mixtures in the process plant non-invasively plays an important role in making sure that the system produces a high quality product without disturbing the nature of the plant. In this case, process tomography can be applied for the chemical mixtures. Thus, the objective of this paper is to review the current research on non-invasive process tomography for detecting chemical mixtures based on hard-field and soft-field tomography. The discussion on liquid-liquid, liquid-solid and liquid-gas two-phase flow for every type of non-invasive process tomography is explained in detail. Consequently, non-invasive process tomography has expanded strongly in chemical applications. Finally, potential future research on the chemical mixture based on ERT is addressed.
format Article
author Abdul Wahab, Yasmin
Abdul Rahim, Ruzairi
Rahiman, Mohd. Hafiz Fazalul
Ridzuan Aw., Suzanna
Mohd. Yunus, Fazlul Rahman
Goh, Chiew Loon
Abdul Rahim, Herlina
Leow, Pei Ling
author_facet Abdul Wahab, Yasmin
Abdul Rahim, Ruzairi
Rahiman, Mohd. Hafiz Fazalul
Ridzuan Aw., Suzanna
Mohd. Yunus, Fazlul Rahman
Goh, Chiew Loon
Abdul Rahim, Herlina
Leow, Pei Ling
author_sort Abdul Wahab, Yasmin
title Non-invasive process tomography in chemical mixtures - a review
title_short Non-invasive process tomography in chemical mixtures - a review
title_full Non-invasive process tomography in chemical mixtures - a review
title_fullStr Non-invasive process tomography in chemical mixtures - a review
title_full_unstemmed Non-invasive process tomography in chemical mixtures - a review
title_sort non-invasive process tomography in chemical mixtures - a review
publisher Elsevier B.V.
publishDate 2015
url http://eprints.utm.my/id/eprint/58649/
http://dx.doi.org/10.1016/j.snb.2014.12.103
_version_ 1712285040693477376
score 13.160551