Development and application of high temperature high performance liquid chromatography to the analysis of pesticides and persistant organic pollutants

A high temperature reversed-phase liquid chromatography (RP-LC) method has been developed to separate polycyclic aromatic hydrocarbons (PAHs) on ODS-silica stationary phase using various proportions of organic modifier in the mobile phase. The selectivity and retention patterns of four PAHs (naphtha...

Full description

Saved in:
Bibliographic Details
Main Authors: Sanagi, Mohd. Marsin, Wan Ibrahim, Wan Aini, Abu Naim, Ahmedy, Md. Saleh, Noorashikin, Norfairulzukry, Norfairul
Format: Monograph
Language:English
Published: Faculty of Science 2008
Subjects:
Online Access:http://eprints.utm.my/id/eprint/5833/1/74255.pdf
http://eprints.utm.my/id/eprint/5833/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.5833
record_format eprints
spelling my.utm.58332017-09-07T03:47:48Z http://eprints.utm.my/id/eprint/5833/ Development and application of high temperature high performance liquid chromatography to the analysis of pesticides and persistant organic pollutants Sanagi, Mohd. Marsin Wan Ibrahim, Wan Aini Abu Naim, Ahmedy Md. Saleh, Noorashikin Norfairulzukry, Norfairul TP Chemical technology A high temperature reversed-phase liquid chromatography (RP-LC) method has been developed to separate polycyclic aromatic hydrocarbons (PAHs) on ODS-silica stationary phase using various proportions of organic modifier in the mobile phase. The selectivity and retention patterns of four PAHs (naphthalene, fluorene, phenanthrene and fluoranthene) were investigated on a Hypersil ODS-silica column (4.6 mm ID × 100 mm, 5 µm) with ultraviolet detection at 254 nm. Excellent separations for the PAHs were achieved with acetonitrile-water 40:60 (v/v) as the mobile phase at a flow rate of 2.5 mL/min at column temperatures ranging from 25°C to 70°C. Pressurized liquid extraction (PLE) method was also developed to determine the quantity of the PAHs in soil samples. It was found that PLE could reduce sample preparation time and reduce organic solvent consumption to one-fifth of that required by Soxhlet extraction (United States Environmental Protection Agency, (US EPA) Method 3545). With dichloromethane-acetone 50:50 (v/v) as the extraction solvent, the optimum conditions were found to be 180°C at a pressure of 250 bar. For the extraction of spiked PAHs, it was found that PLE gave results that are comparable to or better than those obtained by Soxhlet extraction with highest recoveries of fluoranthene 94.4% for PLE and 73.6% for Soxhlet extraction. The developed high-temperature RP-LC method gave limits of detection (LOD) for the PAHs in the range of 0.60 to 1.08 ppm. Faculty of Science 2008 Monograph NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/5833/1/74255.pdf Sanagi, Mohd. Marsin and Wan Ibrahim, Wan Aini and Abu Naim, Ahmedy and Md. Saleh, Noorashikin and Norfairulzukry, Norfairul (2008) Development and application of high temperature high performance liquid chromatography to the analysis of pesticides and persistant organic pollutants. Project Report. Faculty of Science , Skudai, Johor. (Unpublished)
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Sanagi, Mohd. Marsin
Wan Ibrahim, Wan Aini
Abu Naim, Ahmedy
Md. Saleh, Noorashikin
Norfairulzukry, Norfairul
Development and application of high temperature high performance liquid chromatography to the analysis of pesticides and persistant organic pollutants
description A high temperature reversed-phase liquid chromatography (RP-LC) method has been developed to separate polycyclic aromatic hydrocarbons (PAHs) on ODS-silica stationary phase using various proportions of organic modifier in the mobile phase. The selectivity and retention patterns of four PAHs (naphthalene, fluorene, phenanthrene and fluoranthene) were investigated on a Hypersil ODS-silica column (4.6 mm ID × 100 mm, 5 µm) with ultraviolet detection at 254 nm. Excellent separations for the PAHs were achieved with acetonitrile-water 40:60 (v/v) as the mobile phase at a flow rate of 2.5 mL/min at column temperatures ranging from 25°C to 70°C. Pressurized liquid extraction (PLE) method was also developed to determine the quantity of the PAHs in soil samples. It was found that PLE could reduce sample preparation time and reduce organic solvent consumption to one-fifth of that required by Soxhlet extraction (United States Environmental Protection Agency, (US EPA) Method 3545). With dichloromethane-acetone 50:50 (v/v) as the extraction solvent, the optimum conditions were found to be 180°C at a pressure of 250 bar. For the extraction of spiked PAHs, it was found that PLE gave results that are comparable to or better than those obtained by Soxhlet extraction with highest recoveries of fluoranthene 94.4% for PLE and 73.6% for Soxhlet extraction. The developed high-temperature RP-LC method gave limits of detection (LOD) for the PAHs in the range of 0.60 to 1.08 ppm.
format Monograph
author Sanagi, Mohd. Marsin
Wan Ibrahim, Wan Aini
Abu Naim, Ahmedy
Md. Saleh, Noorashikin
Norfairulzukry, Norfairul
author_facet Sanagi, Mohd. Marsin
Wan Ibrahim, Wan Aini
Abu Naim, Ahmedy
Md. Saleh, Noorashikin
Norfairulzukry, Norfairul
author_sort Sanagi, Mohd. Marsin
title Development and application of high temperature high performance liquid chromatography to the analysis of pesticides and persistant organic pollutants
title_short Development and application of high temperature high performance liquid chromatography to the analysis of pesticides and persistant organic pollutants
title_full Development and application of high temperature high performance liquid chromatography to the analysis of pesticides and persistant organic pollutants
title_fullStr Development and application of high temperature high performance liquid chromatography to the analysis of pesticides and persistant organic pollutants
title_full_unstemmed Development and application of high temperature high performance liquid chromatography to the analysis of pesticides and persistant organic pollutants
title_sort development and application of high temperature high performance liquid chromatography to the analysis of pesticides and persistant organic pollutants
publisher Faculty of Science
publishDate 2008
url http://eprints.utm.my/id/eprint/5833/1/74255.pdf
http://eprints.utm.my/id/eprint/5833/
_version_ 1643644414588878848
score 13.2014675