Differential pulse anodic stripping voltammetry determination of copper (II) at glassy carbon electrode in the presence of bis(benzylidene)ethylenediamine as a novel complexing agent
This paper reports on the application of synthesized Schiff base bis(benzylidene)ethylenediamine (BBE) to increase the detection sensitivity of copper (II) at 0.01 V vs Ag/AgCl using glassy carbon electrode. Aliquot of 2.0×10 -3 M of BBE in DMF solution containing BR buffer pH 6 was introduced into...
محفوظ في:
المؤلفون الرئيسيون: | , , |
---|---|
التنسيق: | مقال |
منشور في: |
Malaysian Society of Analytical Sciences
2015
|
الموضوعات: | |
الوصول للمادة أونلاين: | http://eprints.utm.my/id/eprint/58309/ http://mjas.analis.com.my/wp-content/uploads/2018/11/19_2_4.html |
الوسوم: |
إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
|
id |
my.utm.58309 |
---|---|
record_format |
eprints |
spelling |
my.utm.583092021-12-12T04:28:03Z http://eprints.utm.my/id/eprint/58309/ Differential pulse anodic stripping voltammetry determination of copper (II) at glassy carbon electrode in the presence of bis(benzylidene)ethylenediamine as a novel complexing agent Azhari, S. Ahamad, R. Ahmad, Farediah QD Chemistry This paper reports on the application of synthesized Schiff base bis(benzylidene)ethylenediamine (BBE) to increase the detection sensitivity of copper (II) at 0.01 V vs Ag/AgCl using glassy carbon electrode. Aliquot of 2.0×10 -3 M of BBE in DMF solution containing BR buffer pH 6 was introduced into the voltammetric cell followed by the addition of Cu(II) ions and then further proceeded to differential pulse anodic-stripping scan from -1.4 V to +0.3 V vs Ag/AgCl. The optimum parameters obtained were; scan rate; 25 mV/s, accumulation time; 200 sec and accumulation potential; -0.6 V. Under the optimal conditions, the detection limit of 0.4 µgL -1 and a linear response in the range of 1-10 µgL-1 were obtained. The effects of interfering ions such as Cd(II), Cr(III), Fe(II), Pb(II) and Zn(II) were also investigated. The practical applicability of this technique was illustrated by the determination of Cu(II) ions at 3µgL -1 concentration level in tap water with 94.43% of recovery. Malaysian Society of Analytical Sciences 2015 Article PeerReviewed Azhari, S. and Ahamad, R. and Ahmad, Farediah (2015) Differential pulse anodic stripping voltammetry determination of copper (II) at glassy carbon electrode in the presence of bis(benzylidene)ethylenediamine as a novel complexing agent. Malaysian Journal Of Alytical Sciences, 19 (2). pp. 309-317. ISSN 1394-2506 http://mjas.analis.com.my/wp-content/uploads/2018/11/19_2_4.html |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
QD Chemistry |
spellingShingle |
QD Chemistry Azhari, S. Ahamad, R. Ahmad, Farediah Differential pulse anodic stripping voltammetry determination of copper (II) at glassy carbon electrode in the presence of bis(benzylidene)ethylenediamine as a novel complexing agent |
description |
This paper reports on the application of synthesized Schiff base bis(benzylidene)ethylenediamine (BBE) to increase the detection sensitivity of copper (II) at 0.01 V vs Ag/AgCl using glassy carbon electrode. Aliquot of 2.0×10 -3 M of BBE in DMF solution containing BR buffer pH 6 was introduced into the voltammetric cell followed by the addition of Cu(II) ions and then further proceeded to differential pulse anodic-stripping scan from -1.4 V to +0.3 V vs Ag/AgCl. The optimum parameters obtained were; scan rate; 25 mV/s, accumulation time; 200 sec and accumulation potential; -0.6 V. Under the optimal conditions, the detection limit of 0.4 µgL -1 and a linear response in the range of 1-10 µgL-1 were obtained. The effects of interfering ions such as Cd(II), Cr(III), Fe(II), Pb(II) and Zn(II) were also investigated. The practical applicability of this technique was illustrated by the determination of Cu(II) ions at 3µgL -1 concentration level in tap water with 94.43% of recovery. |
format |
Article |
author |
Azhari, S. Ahamad, R. Ahmad, Farediah |
author_facet |
Azhari, S. Ahamad, R. Ahmad, Farediah |
author_sort |
Azhari, S. |
title |
Differential pulse anodic stripping voltammetry determination of copper (II) at glassy carbon electrode in the presence of bis(benzylidene)ethylenediamine as a novel complexing agent |
title_short |
Differential pulse anodic stripping voltammetry determination of copper (II) at glassy carbon electrode in the presence of bis(benzylidene)ethylenediamine as a novel complexing agent |
title_full |
Differential pulse anodic stripping voltammetry determination of copper (II) at glassy carbon electrode in the presence of bis(benzylidene)ethylenediamine as a novel complexing agent |
title_fullStr |
Differential pulse anodic stripping voltammetry determination of copper (II) at glassy carbon electrode in the presence of bis(benzylidene)ethylenediamine as a novel complexing agent |
title_full_unstemmed |
Differential pulse anodic stripping voltammetry determination of copper (II) at glassy carbon electrode in the presence of bis(benzylidene)ethylenediamine as a novel complexing agent |
title_sort |
differential pulse anodic stripping voltammetry determination of copper (ii) at glassy carbon electrode in the presence of bis(benzylidene)ethylenediamine as a novel complexing agent |
publisher |
Malaysian Society of Analytical Sciences |
publishDate |
2015 |
url |
http://eprints.utm.my/id/eprint/58309/ http://mjas.analis.com.my/wp-content/uploads/2018/11/19_2_4.html |
_version_ |
1720436870595215360 |
score |
13.250246 |