Differential pulse anodic stripping voltammetry determination of copper (II) at glassy carbon electrode in the presence of bis(benzylidene)ethylenediamine as a novel complexing agent

This paper reports on the application of synthesized Schiff base bis(benzylidene)ethylenediamine (BBE) to increase the detection sensitivity of copper (II) at 0.01 V vs Ag/AgCl using glassy carbon electrode. Aliquot of 2.0×10 -3 M of BBE in DMF solution containing BR buffer pH 6 was introduced into...

Full description

Saved in:
Bibliographic Details
Main Authors: Azhari, S., Ahamad, R., Ahmad, Farediah
Format: Article
Published: Malaysian Society of Analytical Sciences 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/58309/
http://mjas.analis.com.my/wp-content/uploads/2018/11/19_2_4.html
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.58309
record_format eprints
spelling my.utm.583092021-12-12T04:28:03Z http://eprints.utm.my/id/eprint/58309/ Differential pulse anodic stripping voltammetry determination of copper (II) at glassy carbon electrode in the presence of bis(benzylidene)ethylenediamine as a novel complexing agent Azhari, S. Ahamad, R. Ahmad, Farediah QD Chemistry This paper reports on the application of synthesized Schiff base bis(benzylidene)ethylenediamine (BBE) to increase the detection sensitivity of copper (II) at 0.01 V vs Ag/AgCl using glassy carbon electrode. Aliquot of 2.0×10 -3 M of BBE in DMF solution containing BR buffer pH 6 was introduced into the voltammetric cell followed by the addition of Cu(II) ions and then further proceeded to differential pulse anodic-stripping scan from -1.4 V to +0.3 V vs Ag/AgCl. The optimum parameters obtained were; scan rate; 25 mV/s, accumulation time; 200 sec and accumulation potential; -0.6 V. Under the optimal conditions, the detection limit of 0.4 µgL -1 and a linear response in the range of 1-10 µgL-1 were obtained. The effects of interfering ions such as Cd(II), Cr(III), Fe(II), Pb(II) and Zn(II) were also investigated. The practical applicability of this technique was illustrated by the determination of Cu(II) ions at 3µgL -1 concentration level in tap water with 94.43% of recovery. Malaysian Society of Analytical Sciences 2015 Article PeerReviewed Azhari, S. and Ahamad, R. and Ahmad, Farediah (2015) Differential pulse anodic stripping voltammetry determination of copper (II) at glassy carbon electrode in the presence of bis(benzylidene)ethylenediamine as a novel complexing agent. Malaysian Journal Of Alytical Sciences, 19 (2). pp. 309-317. ISSN 1394-2506 http://mjas.analis.com.my/wp-content/uploads/2018/11/19_2_4.html
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic QD Chemistry
spellingShingle QD Chemistry
Azhari, S.
Ahamad, R.
Ahmad, Farediah
Differential pulse anodic stripping voltammetry determination of copper (II) at glassy carbon electrode in the presence of bis(benzylidene)ethylenediamine as a novel complexing agent
description This paper reports on the application of synthesized Schiff base bis(benzylidene)ethylenediamine (BBE) to increase the detection sensitivity of copper (II) at 0.01 V vs Ag/AgCl using glassy carbon electrode. Aliquot of 2.0×10 -3 M of BBE in DMF solution containing BR buffer pH 6 was introduced into the voltammetric cell followed by the addition of Cu(II) ions and then further proceeded to differential pulse anodic-stripping scan from -1.4 V to +0.3 V vs Ag/AgCl. The optimum parameters obtained were; scan rate; 25 mV/s, accumulation time; 200 sec and accumulation potential; -0.6 V. Under the optimal conditions, the detection limit of 0.4 µgL -1 and a linear response in the range of 1-10 µgL-1 were obtained. The effects of interfering ions such as Cd(II), Cr(III), Fe(II), Pb(II) and Zn(II) were also investigated. The practical applicability of this technique was illustrated by the determination of Cu(II) ions at 3µgL -1 concentration level in tap water with 94.43% of recovery.
format Article
author Azhari, S.
Ahamad, R.
Ahmad, Farediah
author_facet Azhari, S.
Ahamad, R.
Ahmad, Farediah
author_sort Azhari, S.
title Differential pulse anodic stripping voltammetry determination of copper (II) at glassy carbon electrode in the presence of bis(benzylidene)ethylenediamine as a novel complexing agent
title_short Differential pulse anodic stripping voltammetry determination of copper (II) at glassy carbon electrode in the presence of bis(benzylidene)ethylenediamine as a novel complexing agent
title_full Differential pulse anodic stripping voltammetry determination of copper (II) at glassy carbon electrode in the presence of bis(benzylidene)ethylenediamine as a novel complexing agent
title_fullStr Differential pulse anodic stripping voltammetry determination of copper (II) at glassy carbon electrode in the presence of bis(benzylidene)ethylenediamine as a novel complexing agent
title_full_unstemmed Differential pulse anodic stripping voltammetry determination of copper (II) at glassy carbon electrode in the presence of bis(benzylidene)ethylenediamine as a novel complexing agent
title_sort differential pulse anodic stripping voltammetry determination of copper (ii) at glassy carbon electrode in the presence of bis(benzylidene)ethylenediamine as a novel complexing agent
publisher Malaysian Society of Analytical Sciences
publishDate 2015
url http://eprints.utm.my/id/eprint/58309/
http://mjas.analis.com.my/wp-content/uploads/2018/11/19_2_4.html
_version_ 1720436870595215360
score 13.211869