Deblurring computed tomography medical images using a novel amended Landweber algorithm
In computed tomography (CT), blurring occurs due to different hardware or software errors and hides certain medical details that are present in an image. Image blur is difficult to avoid in many circumstances and can frequently ruin an image. For this, many methods have been developed to reduce the...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Published: |
International Association of Scientists
2015
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/58211/ http://dx.doi.org/10.1007/s12539-015-0022-1 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.58211 |
---|---|
record_format |
eprints |
spelling |
my.utm.582112021-09-22T13:49:28Z http://eprints.utm.my/id/eprint/58211/ Deblurring computed tomography medical images using a novel amended Landweber algorithm Al-Ameen, Zohair Sulong, Ghazali QA75 Electronic computers. Computer science In computed tomography (CT), blurring occurs due to different hardware or software errors and hides certain medical details that are present in an image. Image blur is difficult to avoid in many circumstances and can frequently ruin an image. For this, many methods have been developed to reduce the blurring artifact from CT images. The problems with these methods are the high implementation time, noise amplification and boundary artifacts. Hence, this article presents an amended version of the iterative Landweber algorithm to attain artifact-free boundaries and less noise amplification in a faster application time. In this study, both synthetic and real blurred CT images are used to validate the proposed method properly. Similarly, the quality of the processed synthetic images is measured using the feature similarity index, structural similarity and visual information fidelity in pixel domain metrics. Finally, the results obtained from intensive experiments and performance evaluations show the efficiency of the proposed algorithm, which has potential as a new approach in medical image processing. International Association of Scientists 2015 Article PeerReviewed Al-Ameen, Zohair and Sulong, Ghazali (2015) Deblurring computed tomography medical images using a novel amended Landweber algorithm. Interdiscipliry Sciences-Computational Life Sciences, 7 (3). pp. 319-325. ISSN 1913-1844 http://dx.doi.org/10.1007/s12539-015-0022-1 DOI:10.1007/s12539-015-0022-1 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
QA75 Electronic computers. Computer science |
spellingShingle |
QA75 Electronic computers. Computer science Al-Ameen, Zohair Sulong, Ghazali Deblurring computed tomography medical images using a novel amended Landweber algorithm |
description |
In computed tomography (CT), blurring occurs due to different hardware or software errors and hides certain medical details that are present in an image. Image blur is difficult to avoid in many circumstances and can frequently ruin an image. For this, many methods have been developed to reduce the blurring artifact from CT images. The problems with these methods are the high implementation time, noise amplification and boundary artifacts. Hence, this article presents an amended version of the iterative Landweber algorithm to attain artifact-free boundaries and less noise amplification in a faster application time. In this study, both synthetic and real blurred CT images are used to validate the proposed method properly. Similarly, the quality of the processed synthetic images is measured using the feature similarity index, structural similarity and visual information fidelity in pixel domain metrics. Finally, the results obtained from intensive experiments and performance evaluations show the efficiency of the proposed algorithm, which has potential as a new approach in medical image processing. |
format |
Article |
author |
Al-Ameen, Zohair Sulong, Ghazali |
author_facet |
Al-Ameen, Zohair Sulong, Ghazali |
author_sort |
Al-Ameen, Zohair |
title |
Deblurring computed tomography medical images using a novel amended Landweber algorithm |
title_short |
Deblurring computed tomography medical images using a novel amended Landweber algorithm |
title_full |
Deblurring computed tomography medical images using a novel amended Landweber algorithm |
title_fullStr |
Deblurring computed tomography medical images using a novel amended Landweber algorithm |
title_full_unstemmed |
Deblurring computed tomography medical images using a novel amended Landweber algorithm |
title_sort |
deblurring computed tomography medical images using a novel amended landweber algorithm |
publisher |
International Association of Scientists |
publishDate |
2015 |
url |
http://eprints.utm.my/id/eprint/58211/ http://dx.doi.org/10.1007/s12539-015-0022-1 |
_version_ |
1712285031974567936 |
score |
13.211869 |