Comparison of pollutant ambient concentration from two air pollution control (APC) strategies in coal-fired power plant

n this paper, ambient concentrations of Hg and dioxins/furans from two air pollution control (APC) strategies are compared. The strategies include the existing APC strategy at the studied coal - fired power plant (CFPP) and the proposed APC strategy for compliance with parameters in...

Full description

Saved in:
Bibliographic Details
Main Authors: Mokhtar, Mutahharah M., Taib, Mohd. R., Hassim, Mimi H.
Format: Article
Published: 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/58114/
http://dx.doi.org/10.3303/CET1545261
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.58114
record_format eprints
spelling my.utm.581142021-10-25T01:04:30Z http://eprints.utm.my/id/eprint/58114/ Comparison of pollutant ambient concentration from two air pollution control (APC) strategies in coal-fired power plant Mokhtar, Mutahharah M. Taib, Mohd. R. Hassim, Mimi H. TP Chemical technology n this paper, ambient concentrations of Hg and dioxins/furans from two air pollution control (APC) strategies are compared. The strategies include the existing APC strategy at the studied coal - fired power plant (CFPP) and the proposed APC strategy for compliance with parameters in the Environmental Quality (Clean Air) Regulations (CAR) 201 4. The former system consists of electrostatic precipitator (ESP) and flue gas desulphurisation (FGD) which are commonly employed in CFPP in Malaysia, whereas the latter consists of activated carbon injection (ACI), fabric filter (FF) and FGD. It was found that the emissions under the proposed APC strategy of ACI + FF+ FGD have higher margin of limits compared to the existing APC strategy of ESP + FGD. The emissions values were then used as input in AERMOD to predict the ambient concentrations of pollutants . The findings show that the ambient concentrations of Hg and dioxins/furans from both strategies are well below the ambient guideline values, with those emitted from the proposed APC strategy are so low to the point that they are negligible. 2015 Article PeerReviewed Mokhtar, Mutahharah M. and Taib, Mohd. R. and Hassim, Mimi H. (2015) Comparison of pollutant ambient concentration from two air pollution control (APC) strategies in coal-fired power plant. Chemical Engineering Transactions, 45 . pp. 1561-1566. ISSN 2028-3921 http://dx.doi.org/10.3303/CET1545261 DOI: 10.3303/CET1545261
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TP Chemical technology
spellingShingle TP Chemical technology
Mokhtar, Mutahharah M.
Taib, Mohd. R.
Hassim, Mimi H.
Comparison of pollutant ambient concentration from two air pollution control (APC) strategies in coal-fired power plant
description n this paper, ambient concentrations of Hg and dioxins/furans from two air pollution control (APC) strategies are compared. The strategies include the existing APC strategy at the studied coal - fired power plant (CFPP) and the proposed APC strategy for compliance with parameters in the Environmental Quality (Clean Air) Regulations (CAR) 201 4. The former system consists of electrostatic precipitator (ESP) and flue gas desulphurisation (FGD) which are commonly employed in CFPP in Malaysia, whereas the latter consists of activated carbon injection (ACI), fabric filter (FF) and FGD. It was found that the emissions under the proposed APC strategy of ACI + FF+ FGD have higher margin of limits compared to the existing APC strategy of ESP + FGD. The emissions values were then used as input in AERMOD to predict the ambient concentrations of pollutants . The findings show that the ambient concentrations of Hg and dioxins/furans from both strategies are well below the ambient guideline values, with those emitted from the proposed APC strategy are so low to the point that they are negligible.
format Article
author Mokhtar, Mutahharah M.
Taib, Mohd. R.
Hassim, Mimi H.
author_facet Mokhtar, Mutahharah M.
Taib, Mohd. R.
Hassim, Mimi H.
author_sort Mokhtar, Mutahharah M.
title Comparison of pollutant ambient concentration from two air pollution control (APC) strategies in coal-fired power plant
title_short Comparison of pollutant ambient concentration from two air pollution control (APC) strategies in coal-fired power plant
title_full Comparison of pollutant ambient concentration from two air pollution control (APC) strategies in coal-fired power plant
title_fullStr Comparison of pollutant ambient concentration from two air pollution control (APC) strategies in coal-fired power plant
title_full_unstemmed Comparison of pollutant ambient concentration from two air pollution control (APC) strategies in coal-fired power plant
title_sort comparison of pollutant ambient concentration from two air pollution control (apc) strategies in coal-fired power plant
publishDate 2015
url http://eprints.utm.my/id/eprint/58114/
http://dx.doi.org/10.3303/CET1545261
_version_ 1715189639065632768
score 13.18916