Analytical study of end-plate connection on cruciform column section

This paper presents an analytical study on flush end-plate (FEP) and extended end-plate (EEP) connections connected to cruciform column section using component method. The objective of this study is to predict the moment resistance and initial stiffness of FEP and EEP connections on cruciform column...

Full description

Saved in:
Bibliographic Details
Main Authors: Tan, Boon Cheik, Shek, Poi Ngian, Md. Tahir, Mahmood, Mu, Ker Shin
Format: Article
Language:English
Published: Penerbit UTM Press 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/57823/1/TanBoonCheik2015_AnalyticalStudyofEndPlateConnection.pdf
http://eprints.utm.my/id/eprint/57823/
http://dx.doi.org/10.11113/jt.v74.4602
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.57823
record_format eprints
spelling my.utm.578232021-09-05T03:24:50Z http://eprints.utm.my/id/eprint/57823/ Analytical study of end-plate connection on cruciform column section Tan, Boon Cheik Shek, Poi Ngian Md. Tahir, Mahmood Mu, Ker Shin TA Engineering (General). Civil engineering (General) This paper presents an analytical study on flush end-plate (FEP) and extended end-plate (EEP) connections connected to cruciform column section using component method. The objective of this study is to predict the moment resistance and initial stiffness of FEP and EEP connections on cruciform column section. A series of FEP and EEP connections are tested in laboratory. The connection tests consist of four FEP and four EEP specimens with different configuration. Component method outlined in the publication of Steel Construction Institute and British Constructional Steelwork Association are based on BS5950 and Eurocode 3 (EC3) are used to predict the moment resistance and initial stiffness of the tested specimens. The experimental results are then used to validate the analytical predictions. As compare to the experimental results, all moment resistance of the connections coincide well with analytical predictions. Analytical prediction for initial stiffness using EC3 does not show good agreement with the experimental results. This study shows that the component method can be used to predict the moment resistance of FEP and EEP connections on cruciform column section. Further study need to be carried out for initial stiffness to obtain accurate analytical representation. Penerbit UTM Press 2015 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/57823/1/TanBoonCheik2015_AnalyticalStudyofEndPlateConnection.pdf Tan, Boon Cheik and Shek, Poi Ngian and Md. Tahir, Mahmood and Mu, Ker Shin (2015) Analytical study of end-plate connection on cruciform column section. Jurnal Teknologi, 74 (4). pp. 7-11. ISSN 0127-9696 http://dx.doi.org/10.11113/jt.v74.4602 DOI:10.11113/jt.v74.4602
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Tan, Boon Cheik
Shek, Poi Ngian
Md. Tahir, Mahmood
Mu, Ker Shin
Analytical study of end-plate connection on cruciform column section
description This paper presents an analytical study on flush end-plate (FEP) and extended end-plate (EEP) connections connected to cruciform column section using component method. The objective of this study is to predict the moment resistance and initial stiffness of FEP and EEP connections on cruciform column section. A series of FEP and EEP connections are tested in laboratory. The connection tests consist of four FEP and four EEP specimens with different configuration. Component method outlined in the publication of Steel Construction Institute and British Constructional Steelwork Association are based on BS5950 and Eurocode 3 (EC3) are used to predict the moment resistance and initial stiffness of the tested specimens. The experimental results are then used to validate the analytical predictions. As compare to the experimental results, all moment resistance of the connections coincide well with analytical predictions. Analytical prediction for initial stiffness using EC3 does not show good agreement with the experimental results. This study shows that the component method can be used to predict the moment resistance of FEP and EEP connections on cruciform column section. Further study need to be carried out for initial stiffness to obtain accurate analytical representation.
format Article
author Tan, Boon Cheik
Shek, Poi Ngian
Md. Tahir, Mahmood
Mu, Ker Shin
author_facet Tan, Boon Cheik
Shek, Poi Ngian
Md. Tahir, Mahmood
Mu, Ker Shin
author_sort Tan, Boon Cheik
title Analytical study of end-plate connection on cruciform column section
title_short Analytical study of end-plate connection on cruciform column section
title_full Analytical study of end-plate connection on cruciform column section
title_fullStr Analytical study of end-plate connection on cruciform column section
title_full_unstemmed Analytical study of end-plate connection on cruciform column section
title_sort analytical study of end-plate connection on cruciform column section
publisher Penerbit UTM Press
publishDate 2015
url http://eprints.utm.my/id/eprint/57823/1/TanBoonCheik2015_AnalyticalStudyofEndPlateConnection.pdf
http://eprints.utm.my/id/eprint/57823/
http://dx.doi.org/10.11113/jt.v74.4602