A review relations of optical tomography and optical coherance tomography
Optical Tomography (OT) is a form of computed tomography using a digital model of the volume of an object by reconstructing an image of the light transmitted and scattered by the object. OT is used mostly as a form of research in medical imaging. OT depends on the reference object being at least par...
Saved in:
Main Authors: | , , , , , , , , , , |
---|---|
Format: | Article |
Published: |
Penerbit UTM Press
2015
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/57654/ http://dx.doi.org/10.11113/jt.v73.4255 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.57654 |
---|---|
record_format |
eprints |
spelling |
my.utm.576542017-02-08T08:34:01Z http://eprints.utm.my/id/eprint/57654/ A review relations of optical tomography and optical coherance tomography Abd. Rahman, Noor Amizan Ling, Ee Hong Abdul Rahim, Ruzairi Md. Yunus, Mohd Amri Abdul Wahab, Norhaliza Ahmad, Nasaruddin Wahab, Ahmad Ridhwan Jumaah, Mohd. Fahjumi Jamaluddin, Juliza Goh, Chiew Loon Chan, Kok San TK Electrical engineering. Electronics Nuclear engineering Optical Tomography (OT) is a form of computed tomography using a digital model of the volume of an object by reconstructing an image of the light transmitted and scattered by the object. OT is used mostly as a form of research in medical imaging. OT depends on the reference object being at least partially light transmitting or translucent, so it works best on soft tissue, such as breast and brain tissue. Optical Coherence Tomography (OCT) is a new technology for performing high-resolution cross-sectional imaging. OCT is similar to ultrasound imaging, but uses different types of light instead of sound. OCT can provide cross-sectional images of tissue structure on the micrometer scale and in real time. OCT serves as a kind of optical biopsy and is used as a medical diagnostic imaging technology because, unlike conventional histopathology, it does not require the removal and processing of tissue specimens for microscopic examination. The study was carried out to see how the two types of optical imaging and the use of concepts and components used in the system. The light source is used to show different levels of penetration and resolution for both methods is used. The use of an interferometer in optical imaging applications is discussed along with examples of commonly used methods. The optical imaging method contributes significantly to the diversity of tomography systems. Penerbit UTM Press 2015 Article PeerReviewed Abd. Rahman, Noor Amizan and Ling, Ee Hong and Abdul Rahim, Ruzairi and Md. Yunus, Mohd Amri and Abdul Wahab, Norhaliza and Ahmad, Nasaruddin and Wahab, Ahmad Ridhwan and Jumaah, Mohd. Fahjumi and Jamaluddin, Juliza and Goh, Chiew Loon and Chan, Kok San (2015) A review relations of optical tomography and optical coherance tomography. Jurnal Teknologi, 73 (3). pp. 111-117. ISSN 1279-696 http://dx.doi.org/10.11113/jt.v73.4255 DOI:10.11113/jt.v73.4255 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Abd. Rahman, Noor Amizan Ling, Ee Hong Abdul Rahim, Ruzairi Md. Yunus, Mohd Amri Abdul Wahab, Norhaliza Ahmad, Nasaruddin Wahab, Ahmad Ridhwan Jumaah, Mohd. Fahjumi Jamaluddin, Juliza Goh, Chiew Loon Chan, Kok San A review relations of optical tomography and optical coherance tomography |
description |
Optical Tomography (OT) is a form of computed tomography using a digital model of the volume of an object by reconstructing an image of the light transmitted and scattered by the object. OT is used mostly as a form of research in medical imaging. OT depends on the reference object being at least partially light transmitting or translucent, so it works best on soft tissue, such as breast and brain tissue. Optical Coherence Tomography (OCT) is a new technology for performing high-resolution cross-sectional imaging. OCT is similar to ultrasound imaging, but uses different types of light instead of sound. OCT can provide cross-sectional images of tissue structure on the micrometer scale and in real time. OCT serves as a kind of optical biopsy and is used as a medical diagnostic imaging technology because, unlike conventional histopathology, it does not require the removal and processing of tissue specimens for microscopic examination. The study was carried out to see how the two types of optical imaging and the use of concepts and components used in the system. The light source is used to show different levels of penetration and resolution for both methods is used. The use of an interferometer in optical imaging applications is discussed along with examples of commonly used methods. The optical imaging method contributes significantly to the diversity of tomography systems. |
format |
Article |
author |
Abd. Rahman, Noor Amizan Ling, Ee Hong Abdul Rahim, Ruzairi Md. Yunus, Mohd Amri Abdul Wahab, Norhaliza Ahmad, Nasaruddin Wahab, Ahmad Ridhwan Jumaah, Mohd. Fahjumi Jamaluddin, Juliza Goh, Chiew Loon Chan, Kok San |
author_facet |
Abd. Rahman, Noor Amizan Ling, Ee Hong Abdul Rahim, Ruzairi Md. Yunus, Mohd Amri Abdul Wahab, Norhaliza Ahmad, Nasaruddin Wahab, Ahmad Ridhwan Jumaah, Mohd. Fahjumi Jamaluddin, Juliza Goh, Chiew Loon Chan, Kok San |
author_sort |
Abd. Rahman, Noor Amizan |
title |
A review relations of optical tomography and optical coherance tomography |
title_short |
A review relations of optical tomography and optical coherance tomography |
title_full |
A review relations of optical tomography and optical coherance tomography |
title_fullStr |
A review relations of optical tomography and optical coherance tomography |
title_full_unstemmed |
A review relations of optical tomography and optical coherance tomography |
title_sort |
review relations of optical tomography and optical coherance tomography |
publisher |
Penerbit UTM Press |
publishDate |
2015 |
url |
http://eprints.utm.my/id/eprint/57654/ http://dx.doi.org/10.11113/jt.v73.4255 |
_version_ |
1643654040836374528 |
score |
13.211869 |