Initial study of a wire mesh tomography sensor for liquid/gas component investigation

Experimental studies have been carried out to study the principle operation of the conductive type wire-mesh tomography sensor and analyse the wire-mesh tomography sensor for the liquid/gas two-phase flow interface and void fraction distribution in a process column. The measurement of the two-phase...

Full description

Saved in:
Bibliographic Details
Main Authors: Rahiman, Mohd. Hafiz Fazalul, Siow, Lean Thiam, Abd. Rahim, Ruzairi, Zakaria, Zulkarnay, Ang, Vernoon
Format: Article
Published: Korean Institute of Electrical Engineers 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/55962/
http://dx.doi.org/10.5370/JEET.2015.10.5.2205
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.55962
record_format eprints
spelling my.utm.559622017-09-05T07:01:32Z http://eprints.utm.my/id/eprint/55962/ Initial study of a wire mesh tomography sensor for liquid/gas component investigation Rahiman, Mohd. Hafiz Fazalul Siow, Lean Thiam Abd. Rahim, Ruzairi Zakaria, Zulkarnay Ang, Vernoon TK Electrical engineering. Electronics Nuclear engineering Experimental studies have been carried out to study the principle operation of the conductive type wire-mesh tomography sensor and analyse the wire-mesh tomography sensor for the liquid/gas two-phase flow interface and void fraction distribution in a process column. The measurement of the two-phase flows in the process column is based on the cross-sectional local instantaneous conductivity. The sensor consists of two planes of parallel electrode wires with 16 electrodes each and was placed orthogonally with each plane. The sensor electrode wires were made of tinned copper wire with an outer diameter of 0.91 mm which stretched over the sensor fixture. Therefore, this result in the mesh grid size with 5 53×5.53mm2. The wire-mesh sensor was tested in a horizontal liquid/gas two-phase flows process column with nominal diameter of 95.6 mm and the sampling frequency of 5882.3529 Hz. The tomogram results show that the wire-mesh tomography provides significant results to represent the void fraction distribution in the process column and estimation error was found in the liquid/gas interface level Korean Institute of Electrical Engineers 2015-09 Article PeerReviewed Rahiman, Mohd. Hafiz Fazalul and Siow, Lean Thiam and Abd. Rahim, Ruzairi and Zakaria, Zulkarnay and Ang, Vernoon (2015) Initial study of a wire mesh tomography sensor for liquid/gas component investigation. Journal of Electrical Engineering and Technology, 10 (5). pp. 2205-2210. ISSN 1975-0102 http://dx.doi.org/10.5370/JEET.2015.10.5.2205 DOI:10.5370/JEET.2015.10.5.2205
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Rahiman, Mohd. Hafiz Fazalul
Siow, Lean Thiam
Abd. Rahim, Ruzairi
Zakaria, Zulkarnay
Ang, Vernoon
Initial study of a wire mesh tomography sensor for liquid/gas component investigation
description Experimental studies have been carried out to study the principle operation of the conductive type wire-mesh tomography sensor and analyse the wire-mesh tomography sensor for the liquid/gas two-phase flow interface and void fraction distribution in a process column. The measurement of the two-phase flows in the process column is based on the cross-sectional local instantaneous conductivity. The sensor consists of two planes of parallel electrode wires with 16 electrodes each and was placed orthogonally with each plane. The sensor electrode wires were made of tinned copper wire with an outer diameter of 0.91 mm which stretched over the sensor fixture. Therefore, this result in the mesh grid size with 5 53×5.53mm2. The wire-mesh sensor was tested in a horizontal liquid/gas two-phase flows process column with nominal diameter of 95.6 mm and the sampling frequency of 5882.3529 Hz. The tomogram results show that the wire-mesh tomography provides significant results to represent the void fraction distribution in the process column and estimation error was found in the liquid/gas interface level
format Article
author Rahiman, Mohd. Hafiz Fazalul
Siow, Lean Thiam
Abd. Rahim, Ruzairi
Zakaria, Zulkarnay
Ang, Vernoon
author_facet Rahiman, Mohd. Hafiz Fazalul
Siow, Lean Thiam
Abd. Rahim, Ruzairi
Zakaria, Zulkarnay
Ang, Vernoon
author_sort Rahiman, Mohd. Hafiz Fazalul
title Initial study of a wire mesh tomography sensor for liquid/gas component investigation
title_short Initial study of a wire mesh tomography sensor for liquid/gas component investigation
title_full Initial study of a wire mesh tomography sensor for liquid/gas component investigation
title_fullStr Initial study of a wire mesh tomography sensor for liquid/gas component investigation
title_full_unstemmed Initial study of a wire mesh tomography sensor for liquid/gas component investigation
title_sort initial study of a wire mesh tomography sensor for liquid/gas component investigation
publisher Korean Institute of Electrical Engineers
publishDate 2015
url http://eprints.utm.my/id/eprint/55962/
http://dx.doi.org/10.5370/JEET.2015.10.5.2205
_version_ 1643653953637842944
score 13.160551