Visualization of pulsatile CSF motion around membrane-like structures with both 4D velocity mapping and time-SLIP technique

Purpose: We compared the depiction of pulsatile CSF motion obtained by 4-dimensional phase-contrast velocity mapping (4D-VM) with that by time-spatial labeling inversion pulse (time-SLIP) technique in the presence of membrane structures. Materials and Methods: We compared the 2 techniques using a fl...

Full description

Saved in:
Bibliographic Details
Main Authors: Hirayama, Akihiro, Matsumae, Mitsunori, Yatsushiro, Satoshi, Abdulla, Afnizanfaizal, Atsumi, Hideki, Kuroda, Kagayaki
Format: Article
Language:English
Published: Japan Society of Magnetic Resonance in Medicine 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/55887/1/AkihiroHirayama2015_VisualizationofPulsatileCSFMotion.pdf
http://eprints.utm.my/id/eprint/55887/
http://dx.doi.org/10.2463/mrms.2014-0089
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.55887
record_format eprints
spelling my.utm.558872016-10-12T07:17:26Z http://eprints.utm.my/id/eprint/55887/ Visualization of pulsatile CSF motion around membrane-like structures with both 4D velocity mapping and time-SLIP technique Hirayama, Akihiro Matsumae, Mitsunori Yatsushiro, Satoshi Abdulla, Afnizanfaizal Atsumi, Hideki Kuroda, Kagayaki R Medicine (General) Purpose: We compared the depiction of pulsatile CSF motion obtained by 4-dimensional phase-contrast velocity mapping (4D-VM) with that by time-spatial labeling inversion pulse (time-SLIP) technique in the presence of membrane structures. Materials and Methods: We compared the 2 techniques using a flow phantom comprising tubes with and without a thin rubber membrane and applied the techniques to 6 healthy volunteers and 2 patients to analyze CSF dynamics surrounding thin membrane structures, such as the Liliequist membrane (LM), or the wall of an arachnoid cyst. Results: Phantom images exhibited propagation of the flow and pressure gradient beyond the membrane in the tube. In contrast, fluid labeled by the time-SLIP technique showed little displacement from the blockage of spin travelling by the membrane. A similar phenomenon was observed around the LM in healthy volunteers and the arachnoid cyst wall in a patient. Conclusion: Four-dimensional phase-contrast velocity mapping permitted visualization of the propagation of CSF pulsation through the intracranial membranous structures. This suggests that 4D-VM and the time-SLIP technique provide different information on flow and that both techniques are useful for classifying the pathophysiological status of CSF and elucidating the propagation pathway of CSF pulsation in the cranium. Japan Society of Magnetic Resonance in Medicine 2015-11-13 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/55887/1/AkihiroHirayama2015_VisualizationofPulsatileCSFMotion.pdf Hirayama, Akihiro and Matsumae, Mitsunori and Yatsushiro, Satoshi and Abdulla, Afnizanfaizal and Atsumi, Hideki and Kuroda, Kagayaki (2015) Visualization of pulsatile CSF motion around membrane-like structures with both 4D velocity mapping and time-SLIP technique. Magnetic Resonance in Medical Sciences, 14 (4). pp. 263-273. ISSN 1347-3182 http://dx.doi.org/10.2463/mrms.2014-0089 DOI:10.2463/mrms.2014-0089
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic R Medicine (General)
spellingShingle R Medicine (General)
Hirayama, Akihiro
Matsumae, Mitsunori
Yatsushiro, Satoshi
Abdulla, Afnizanfaizal
Atsumi, Hideki
Kuroda, Kagayaki
Visualization of pulsatile CSF motion around membrane-like structures with both 4D velocity mapping and time-SLIP technique
description Purpose: We compared the depiction of pulsatile CSF motion obtained by 4-dimensional phase-contrast velocity mapping (4D-VM) with that by time-spatial labeling inversion pulse (time-SLIP) technique in the presence of membrane structures. Materials and Methods: We compared the 2 techniques using a flow phantom comprising tubes with and without a thin rubber membrane and applied the techniques to 6 healthy volunteers and 2 patients to analyze CSF dynamics surrounding thin membrane structures, such as the Liliequist membrane (LM), or the wall of an arachnoid cyst. Results: Phantom images exhibited propagation of the flow and pressure gradient beyond the membrane in the tube. In contrast, fluid labeled by the time-SLIP technique showed little displacement from the blockage of spin travelling by the membrane. A similar phenomenon was observed around the LM in healthy volunteers and the arachnoid cyst wall in a patient. Conclusion: Four-dimensional phase-contrast velocity mapping permitted visualization of the propagation of CSF pulsation through the intracranial membranous structures. This suggests that 4D-VM and the time-SLIP technique provide different information on flow and that both techniques are useful for classifying the pathophysiological status of CSF and elucidating the propagation pathway of CSF pulsation in the cranium.
format Article
author Hirayama, Akihiro
Matsumae, Mitsunori
Yatsushiro, Satoshi
Abdulla, Afnizanfaizal
Atsumi, Hideki
Kuroda, Kagayaki
author_facet Hirayama, Akihiro
Matsumae, Mitsunori
Yatsushiro, Satoshi
Abdulla, Afnizanfaizal
Atsumi, Hideki
Kuroda, Kagayaki
author_sort Hirayama, Akihiro
title Visualization of pulsatile CSF motion around membrane-like structures with both 4D velocity mapping and time-SLIP technique
title_short Visualization of pulsatile CSF motion around membrane-like structures with both 4D velocity mapping and time-SLIP technique
title_full Visualization of pulsatile CSF motion around membrane-like structures with both 4D velocity mapping and time-SLIP technique
title_fullStr Visualization of pulsatile CSF motion around membrane-like structures with both 4D velocity mapping and time-SLIP technique
title_full_unstemmed Visualization of pulsatile CSF motion around membrane-like structures with both 4D velocity mapping and time-SLIP technique
title_sort visualization of pulsatile csf motion around membrane-like structures with both 4d velocity mapping and time-slip technique
publisher Japan Society of Magnetic Resonance in Medicine
publishDate 2015
url http://eprints.utm.my/id/eprint/55887/1/AkihiroHirayama2015_VisualizationofPulsatileCSFMotion.pdf
http://eprints.utm.my/id/eprint/55887/
http://dx.doi.org/10.2463/mrms.2014-0089
_version_ 1643653930981261312
score 13.211869