Visualization of pulsatile CSF motion around membrane-like structures with both 4D velocity mapping and time-SLIP technique
Purpose: We compared the depiction of pulsatile CSF motion obtained by 4-dimensional phase-contrast velocity mapping (4D-VM) with that by time-spatial labeling inversion pulse (time-SLIP) technique in the presence of membrane structures. Materials and Methods: We compared the 2 techniques using a fl...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Japan Society of Magnetic Resonance in Medicine
2015
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/55887/1/AkihiroHirayama2015_VisualizationofPulsatileCSFMotion.pdf http://eprints.utm.my/id/eprint/55887/ http://dx.doi.org/10.2463/mrms.2014-0089 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.55887 |
---|---|
record_format |
eprints |
spelling |
my.utm.558872016-10-12T07:17:26Z http://eprints.utm.my/id/eprint/55887/ Visualization of pulsatile CSF motion around membrane-like structures with both 4D velocity mapping and time-SLIP technique Hirayama, Akihiro Matsumae, Mitsunori Yatsushiro, Satoshi Abdulla, Afnizanfaizal Atsumi, Hideki Kuroda, Kagayaki R Medicine (General) Purpose: We compared the depiction of pulsatile CSF motion obtained by 4-dimensional phase-contrast velocity mapping (4D-VM) with that by time-spatial labeling inversion pulse (time-SLIP) technique in the presence of membrane structures. Materials and Methods: We compared the 2 techniques using a flow phantom comprising tubes with and without a thin rubber membrane and applied the techniques to 6 healthy volunteers and 2 patients to analyze CSF dynamics surrounding thin membrane structures, such as the Liliequist membrane (LM), or the wall of an arachnoid cyst. Results: Phantom images exhibited propagation of the flow and pressure gradient beyond the membrane in the tube. In contrast, fluid labeled by the time-SLIP technique showed little displacement from the blockage of spin travelling by the membrane. A similar phenomenon was observed around the LM in healthy volunteers and the arachnoid cyst wall in a patient. Conclusion: Four-dimensional phase-contrast velocity mapping permitted visualization of the propagation of CSF pulsation through the intracranial membranous structures. This suggests that 4D-VM and the time-SLIP technique provide different information on flow and that both techniques are useful for classifying the pathophysiological status of CSF and elucidating the propagation pathway of CSF pulsation in the cranium. Japan Society of Magnetic Resonance in Medicine 2015-11-13 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/55887/1/AkihiroHirayama2015_VisualizationofPulsatileCSFMotion.pdf Hirayama, Akihiro and Matsumae, Mitsunori and Yatsushiro, Satoshi and Abdulla, Afnizanfaizal and Atsumi, Hideki and Kuroda, Kagayaki (2015) Visualization of pulsatile CSF motion around membrane-like structures with both 4D velocity mapping and time-SLIP technique. Magnetic Resonance in Medical Sciences, 14 (4). pp. 263-273. ISSN 1347-3182 http://dx.doi.org/10.2463/mrms.2014-0089 DOI:10.2463/mrms.2014-0089 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
R Medicine (General) |
spellingShingle |
R Medicine (General) Hirayama, Akihiro Matsumae, Mitsunori Yatsushiro, Satoshi Abdulla, Afnizanfaizal Atsumi, Hideki Kuroda, Kagayaki Visualization of pulsatile CSF motion around membrane-like structures with both 4D velocity mapping and time-SLIP technique |
description |
Purpose: We compared the depiction of pulsatile CSF motion obtained by 4-dimensional phase-contrast velocity mapping (4D-VM) with that by time-spatial labeling inversion pulse (time-SLIP) technique in the presence of membrane structures. Materials and Methods: We compared the 2 techniques using a flow phantom comprising tubes with and without a thin rubber membrane and applied the techniques to 6 healthy volunteers and 2 patients to analyze CSF dynamics surrounding thin membrane structures, such as the Liliequist membrane (LM), or the wall of an arachnoid cyst. Results: Phantom images exhibited propagation of the flow and pressure gradient beyond the membrane in the tube. In contrast, fluid labeled by the time-SLIP technique showed little displacement from the blockage of spin travelling by the membrane. A similar phenomenon was observed around the LM in healthy volunteers and the arachnoid cyst wall in a patient. Conclusion: Four-dimensional phase-contrast velocity mapping permitted visualization of the propagation of CSF pulsation through the intracranial membranous structures. This suggests that 4D-VM and the time-SLIP technique provide different information on flow and that both techniques are useful for classifying the pathophysiological status of CSF and elucidating the propagation pathway of CSF pulsation in the cranium. |
format |
Article |
author |
Hirayama, Akihiro Matsumae, Mitsunori Yatsushiro, Satoshi Abdulla, Afnizanfaizal Atsumi, Hideki Kuroda, Kagayaki |
author_facet |
Hirayama, Akihiro Matsumae, Mitsunori Yatsushiro, Satoshi Abdulla, Afnizanfaizal Atsumi, Hideki Kuroda, Kagayaki |
author_sort |
Hirayama, Akihiro |
title |
Visualization of pulsatile CSF motion around membrane-like structures with both 4D velocity mapping and time-SLIP technique |
title_short |
Visualization of pulsatile CSF motion around membrane-like structures with both 4D velocity mapping and time-SLIP technique |
title_full |
Visualization of pulsatile CSF motion around membrane-like structures with both 4D velocity mapping and time-SLIP technique |
title_fullStr |
Visualization of pulsatile CSF motion around membrane-like structures with both 4D velocity mapping and time-SLIP technique |
title_full_unstemmed |
Visualization of pulsatile CSF motion around membrane-like structures with both 4D velocity mapping and time-SLIP technique |
title_sort |
visualization of pulsatile csf motion around membrane-like structures with both 4d velocity mapping and time-slip technique |
publisher |
Japan Society of Magnetic Resonance in Medicine |
publishDate |
2015 |
url |
http://eprints.utm.my/id/eprint/55887/1/AkihiroHirayama2015_VisualizationofPulsatileCSFMotion.pdf http://eprints.utm.my/id/eprint/55887/ http://dx.doi.org/10.2463/mrms.2014-0089 |
_version_ |
1643653930981261312 |
score |
13.211869 |