Wireless powered thermo-pneumatic micropump using frequency-controlled heater

This paper reports a novel, wirelessly powered micropump based on thermo-pneumatic actuation using a frequency-controlled heater. The micropump operates wirelessly through the energy transfer to a frequency-dependent heater, which was placed underneath the heating chamber of the pump. Heat is genera...

Full description

Saved in:
Bibliographic Details
Main Authors: Pei, Song Cheea, Minjal, Marwan Nafea, Pei, Ling Leow, Mohamed Ali, Mohamed Sultan
Format: Article
Language:English
Published: Elsevier 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/55791/1/PeisongChee2015_WirelessPoweredThermoPneumaticMicropumpUsingFrequency.pdf
http://eprints.utm.my/id/eprint/55791/
http://dx.doi.org/10.1016/j.sna.2015.06.017
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.55791
record_format eprints
spelling my.utm.557912017-08-25T01:43:13Z http://eprints.utm.my/id/eprint/55791/ Wireless powered thermo-pneumatic micropump using frequency-controlled heater Pei, Song Cheea Minjal, Marwan Nafea Pei, Ling Leow Mohamed Ali, Mohamed Sultan TK Electrical engineering. Electronics Nuclear engineering This paper reports a novel, wirelessly powered micropump based on thermo-pneumatic actuation using a frequency-controlled heater. The micropump operates wirelessly through the energy transfer to a frequency-dependent heater, which was placed underneath the heating chamber of the pump. Heat is generated at the wireless heater when the external magnetic field is tuned to the resonant frequency of the heater. The enclosed air in the chamber expands and forces the liquid to flow out from the reservoir. The developed device is able to pump a total volume of 4 ml in a single stroke when the external field frequency is tuned to the resonant frequency of the heater at the output power of 0.22 W. Multiple strokes pumping are feasible to be performed with the volume variation of ~2.8% between each stroke. Flow rate performance of the micropump ranges from 1.01 µL/min to 5.24 µL/min by manipulating the heating power from 0.07 W to 0.89 W. In addition, numerical simulation was performed to study the influence of the heat transfer to the sample liquid. The presented micropump exclusively offers a promising solution in biomedical implantation devices due to its remotely powered functionality, free from bubble trapping and biocompatible feature. Elsevier 2015-06-29 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/55791/1/PeisongChee2015_WirelessPoweredThermoPneumaticMicropumpUsingFrequency.pdf Pei, Song Cheea and Minjal, Marwan Nafea and Pei, Ling Leow and Mohamed Ali, Mohamed Sultan (2015) Wireless powered thermo-pneumatic micropump using frequency-controlled heater. Sensors and Actuators, A: Physical, 233 . pp. 1-8. ISSN 0924-4247 http://dx.doi.org/10.1016/j.sna.2015.06.017 DOI:10.1016/j.sna.2015.06.017
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Pei, Song Cheea
Minjal, Marwan Nafea
Pei, Ling Leow
Mohamed Ali, Mohamed Sultan
Wireless powered thermo-pneumatic micropump using frequency-controlled heater
description This paper reports a novel, wirelessly powered micropump based on thermo-pneumatic actuation using a frequency-controlled heater. The micropump operates wirelessly through the energy transfer to a frequency-dependent heater, which was placed underneath the heating chamber of the pump. Heat is generated at the wireless heater when the external magnetic field is tuned to the resonant frequency of the heater. The enclosed air in the chamber expands and forces the liquid to flow out from the reservoir. The developed device is able to pump a total volume of 4 ml in a single stroke when the external field frequency is tuned to the resonant frequency of the heater at the output power of 0.22 W. Multiple strokes pumping are feasible to be performed with the volume variation of ~2.8% between each stroke. Flow rate performance of the micropump ranges from 1.01 µL/min to 5.24 µL/min by manipulating the heating power from 0.07 W to 0.89 W. In addition, numerical simulation was performed to study the influence of the heat transfer to the sample liquid. The presented micropump exclusively offers a promising solution in biomedical implantation devices due to its remotely powered functionality, free from bubble trapping and biocompatible feature.
format Article
author Pei, Song Cheea
Minjal, Marwan Nafea
Pei, Ling Leow
Mohamed Ali, Mohamed Sultan
author_facet Pei, Song Cheea
Minjal, Marwan Nafea
Pei, Ling Leow
Mohamed Ali, Mohamed Sultan
author_sort Pei, Song Cheea
title Wireless powered thermo-pneumatic micropump using frequency-controlled heater
title_short Wireless powered thermo-pneumatic micropump using frequency-controlled heater
title_full Wireless powered thermo-pneumatic micropump using frequency-controlled heater
title_fullStr Wireless powered thermo-pneumatic micropump using frequency-controlled heater
title_full_unstemmed Wireless powered thermo-pneumatic micropump using frequency-controlled heater
title_sort wireless powered thermo-pneumatic micropump using frequency-controlled heater
publisher Elsevier
publishDate 2015
url http://eprints.utm.my/id/eprint/55791/1/PeisongChee2015_WirelessPoweredThermoPneumaticMicropumpUsingFrequency.pdf
http://eprints.utm.my/id/eprint/55791/
http://dx.doi.org/10.1016/j.sna.2015.06.017
_version_ 1643653902351990784
score 13.160551