Frequency restrictions for wireless power transfer of implantable medical devices

Wireless power transfer (WPT) system is turning to be a reliable strategy to power implantable devices. However, WPT possess strong reactive near-field to induce electric fields in the body tissue of implant wearer. In addition, implantable devices with WPT may be exposed to the unwanted strong elec...

Full description

Saved in:
Bibliographic Details
Main Authors: Awal, Md. Rabiul, Jusoh, Muzammil T., Che Beson, Mohd. Rashidi, Sabapathy, Thennarasan, Kamarudin, Muhammad Ramlee, Basar, Md. Rubel Ubel
Format: Article
Published: Asian Research Publishing Network (ARPN) 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/55406/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.55406
record_format eprints
spelling my.utm.554062017-02-15T06:48:46Z http://eprints.utm.my/id/eprint/55406/ Frequency restrictions for wireless power transfer of implantable medical devices Awal, Md. Rabiul Jusoh, Muzammil T. Che Beson, Mohd. Rashidi Sabapathy, Thennarasan Kamarudin, Muhammad Ramlee Basar, Md. Rubel Ubel TK Electrical engineering. Electronics Nuclear engineering Wireless power transfer (WPT) system is turning to be a reliable strategy to power implantable devices. However, WPT possess strong reactive near-field to induce electric fields in the body tissue of implant wearer. In addition, implantable devices with WPT may be exposed to the unwanted strong electromagnetic field and be disturbed functionally. These may pose potential direct health hazards or serious damage to the function of health via interference with medical implants. In this paper, the safety guidelines from different responsible organization are reviewed and discussed in the context of human safety. Based on the discussion and literature review, the effect and affect of state-of-the-art of the existing guidelines are discussed. As an outcome, several needs to be added as the extension of safety guidelines for coverage of persons with implants, more computationally efficient full wave solvers, more reliable human models has to be introduced Asian Research Publishing Network (ARPN) 2015 Article PeerReviewed Awal, Md. Rabiul and Jusoh, Muzammil T. and Che Beson, Mohd. Rashidi and Sabapathy, Thennarasan and Kamarudin, Muhammad Ramlee and Basar, Md. Rubel Ubel (2015) Frequency restrictions for wireless power transfer of implantable medical devices. ARPN Journal of Engineering and Applied Sciences, 10 (19). pp. 8707-8714. ISSN 1819-6608
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Awal, Md. Rabiul
Jusoh, Muzammil T.
Che Beson, Mohd. Rashidi
Sabapathy, Thennarasan
Kamarudin, Muhammad Ramlee
Basar, Md. Rubel Ubel
Frequency restrictions for wireless power transfer of implantable medical devices
description Wireless power transfer (WPT) system is turning to be a reliable strategy to power implantable devices. However, WPT possess strong reactive near-field to induce electric fields in the body tissue of implant wearer. In addition, implantable devices with WPT may be exposed to the unwanted strong electromagnetic field and be disturbed functionally. These may pose potential direct health hazards or serious damage to the function of health via interference with medical implants. In this paper, the safety guidelines from different responsible organization are reviewed and discussed in the context of human safety. Based on the discussion and literature review, the effect and affect of state-of-the-art of the existing guidelines are discussed. As an outcome, several needs to be added as the extension of safety guidelines for coverage of persons with implants, more computationally efficient full wave solvers, more reliable human models has to be introduced
format Article
author Awal, Md. Rabiul
Jusoh, Muzammil T.
Che Beson, Mohd. Rashidi
Sabapathy, Thennarasan
Kamarudin, Muhammad Ramlee
Basar, Md. Rubel Ubel
author_facet Awal, Md. Rabiul
Jusoh, Muzammil T.
Che Beson, Mohd. Rashidi
Sabapathy, Thennarasan
Kamarudin, Muhammad Ramlee
Basar, Md. Rubel Ubel
author_sort Awal, Md. Rabiul
title Frequency restrictions for wireless power transfer of implantable medical devices
title_short Frequency restrictions for wireless power transfer of implantable medical devices
title_full Frequency restrictions for wireless power transfer of implantable medical devices
title_fullStr Frequency restrictions for wireless power transfer of implantable medical devices
title_full_unstemmed Frequency restrictions for wireless power transfer of implantable medical devices
title_sort frequency restrictions for wireless power transfer of implantable medical devices
publisher Asian Research Publishing Network (ARPN)
publishDate 2015
url http://eprints.utm.my/id/eprint/55406/
_version_ 1643653787555987456
score 13.188404