Fabricated metal-free carbon nitride characterizations for fluorescence chemical sensor of nitrate ions

In this study, a metal-free carbon nitride (CN) was investigated for the first time as a potential fluorescence sensor for detection of nitrate ions (NO3-). The CN was prepared through thermal polymerization of urea precursor at 823 K and characterized by diffuse reflectance ultraviolet-visible (DR...

Full description

Saved in:
Bibliographic Details
Main Authors: Alim, Nor Shuhada, Lintang, Hendrik O., Yuliati, Leny
Format: Article
Language:English
Published: Penerbit UTM Press 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/55216/1/LenyYuliaty2015_FabricatedMetalFreeCarbonNitrideCharacterizations.pdf
http://eprints.utm.my/id/eprint/55216/
http://dx.doi.org/10.11113/jt.v76.5812
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.55216
record_format eprints
spelling my.utm.552162017-11-01T04:16:49Z http://eprints.utm.my/id/eprint/55216/ Fabricated metal-free carbon nitride characterizations for fluorescence chemical sensor of nitrate ions Alim, Nor Shuhada Lintang, Hendrik O. Yuliati, Leny QD Chemistry In this study, a metal-free carbon nitride (CN) was investigated for the first time as a potential fluorescence sensor for detection of nitrate ions (NO3-). The CN was prepared through thermal polymerization of urea precursor at 823 K and characterized by diffuse reflectance ultraviolet-visible (DR UV-Vis), Fourier transform infrared (FTIR), and fluorescence spectroscopies. The DR UV-Vis spectrum confirmed that CN could absorb light up to 450 nm. On the other hand, the FTIR spectrum revealed the presence of graphitic CN single and double bond characters in the 800-1700 cm-1 region. From the fluorescence spectroscopy, three excitation peaks at 278, 310 and 369 nm were observed due to the presence of N=C, C=O and N-C groups, respectively. The fluorescence sensor capability of the CN was then investigated using concentrations of NO3- in the range of 300-1800 ?M. It was confirmed that the intensities of the emission sites were quenched linearly with the concentrations of the NO3-. The CN showed good reproducibility with relative standard deviation (RSD) values were 1.5-7.2%. These results suggested that CN can act as the fluorescence sensor for NO3- Penerbit UTM Press 2015-06 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/55216/1/LenyYuliaty2015_FabricatedMetalFreeCarbonNitrideCharacterizations.pdf Alim, Nor Shuhada and Lintang, Hendrik O. and Yuliati, Leny (2015) Fabricated metal-free carbon nitride characterizations for fluorescence chemical sensor of nitrate ions. Jurnal Teknologi, 76 (13). pp. 1-6. ISSN 2180-3722 http://dx.doi.org/10.11113/jt.v76.5812 DOI:10.11113/jt.v76.5812
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic QD Chemistry
spellingShingle QD Chemistry
Alim, Nor Shuhada
Lintang, Hendrik O.
Yuliati, Leny
Fabricated metal-free carbon nitride characterizations for fluorescence chemical sensor of nitrate ions
description In this study, a metal-free carbon nitride (CN) was investigated for the first time as a potential fluorescence sensor for detection of nitrate ions (NO3-). The CN was prepared through thermal polymerization of urea precursor at 823 K and characterized by diffuse reflectance ultraviolet-visible (DR UV-Vis), Fourier transform infrared (FTIR), and fluorescence spectroscopies. The DR UV-Vis spectrum confirmed that CN could absorb light up to 450 nm. On the other hand, the FTIR spectrum revealed the presence of graphitic CN single and double bond characters in the 800-1700 cm-1 region. From the fluorescence spectroscopy, three excitation peaks at 278, 310 and 369 nm were observed due to the presence of N=C, C=O and N-C groups, respectively. The fluorescence sensor capability of the CN was then investigated using concentrations of NO3- in the range of 300-1800 ?M. It was confirmed that the intensities of the emission sites were quenched linearly with the concentrations of the NO3-. The CN showed good reproducibility with relative standard deviation (RSD) values were 1.5-7.2%. These results suggested that CN can act as the fluorescence sensor for NO3-
format Article
author Alim, Nor Shuhada
Lintang, Hendrik O.
Yuliati, Leny
author_facet Alim, Nor Shuhada
Lintang, Hendrik O.
Yuliati, Leny
author_sort Alim, Nor Shuhada
title Fabricated metal-free carbon nitride characterizations for fluorescence chemical sensor of nitrate ions
title_short Fabricated metal-free carbon nitride characterizations for fluorescence chemical sensor of nitrate ions
title_full Fabricated metal-free carbon nitride characterizations for fluorescence chemical sensor of nitrate ions
title_fullStr Fabricated metal-free carbon nitride characterizations for fluorescence chemical sensor of nitrate ions
title_full_unstemmed Fabricated metal-free carbon nitride characterizations for fluorescence chemical sensor of nitrate ions
title_sort fabricated metal-free carbon nitride characterizations for fluorescence chemical sensor of nitrate ions
publisher Penerbit UTM Press
publishDate 2015
url http://eprints.utm.my/id/eprint/55216/1/LenyYuliaty2015_FabricatedMetalFreeCarbonNitrideCharacterizations.pdf
http://eprints.utm.my/id/eprint/55216/
http://dx.doi.org/10.11113/jt.v76.5812
_version_ 1643653729471168512
score 13.18916