Arterial hemodynamics in patent ductus arteriosus stenting

Cyanotic congenital heart disease (CHD) is the condition when insufficient blood transported throughout the whole body due to anomalies of blood vessels or heart. Hence, the procedure of maintaing the patency of ductus arteriosus were introduced where the stent is implanted at ductus arteriosus that...

Full description

Saved in:
Bibliographic Details
Main Author: Jamalruhanordin, Fara Lyana
Format: Thesis
Language:English
Published: 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/53856/1/FaraLyanaJamalruhanordinMFBME2015.pdf
http://eprints.utm.my/id/eprint/53856/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:85894
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.53856
record_format eprints
spelling my.utm.538562020-09-08T08:03:25Z http://eprints.utm.my/id/eprint/53856/ Arterial hemodynamics in patent ductus arteriosus stenting Jamalruhanordin, Fara Lyana R Medicine (General) Cyanotic congenital heart disease (CHD) is the condition when insufficient blood transported throughout the whole body due to anomalies of blood vessels or heart. Hence, the procedure of maintaing the patency of ductus arteriosus were introduced where the stent is implanted at ductus arteriosus that should be closed naturally within 48 hours after the birth. The main purpose of this study is to investigate the hemodyamic effect of patent ductus arteriosus (PDA) after different types of stent design were implanted. Three different types of commercial stent design were used in this study: Closed Cell V stent, Palmaz-Schatz stent and Type One stent. The hemodynamic effect were investigated numerically via computational fluid dynamics by using ANSYS 14.0 software. Three hemodynamics variables were analysed in this study which are wall shear stress (WSS), oscillatory shear index (OSI) and relative residence time (RRT). Each stent affect the hemodynamic within PDA differently. The higher percentage of TAWSS exposed in range of 0.5 Pa to 2 Pa is better shown by Closed Cell V stent with 25.4%. Type One stent shown a good result in OSI which has high percentages exposed below 0.2 with the value of 34%. Palmaz-Schatz stent present a preferable results in both WSS low, 1.2% (low the better) and RRT within range of 10 Pa^-1 at 97.7%. Thus, this study can be useful in stent selection for PDA stenting. 2015-07 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/53856/1/FaraLyanaJamalruhanordinMFBME2015.pdf Jamalruhanordin, Fara Lyana (2015) Arterial hemodynamics in patent ductus arteriosus stenting. Masters thesis, Universiti Teknologi Malaysia, Faculty of Biosciences and Medical Engineering. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:85894
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic R Medicine (General)
spellingShingle R Medicine (General)
Jamalruhanordin, Fara Lyana
Arterial hemodynamics in patent ductus arteriosus stenting
description Cyanotic congenital heart disease (CHD) is the condition when insufficient blood transported throughout the whole body due to anomalies of blood vessels or heart. Hence, the procedure of maintaing the patency of ductus arteriosus were introduced where the stent is implanted at ductus arteriosus that should be closed naturally within 48 hours after the birth. The main purpose of this study is to investigate the hemodyamic effect of patent ductus arteriosus (PDA) after different types of stent design were implanted. Three different types of commercial stent design were used in this study: Closed Cell V stent, Palmaz-Schatz stent and Type One stent. The hemodynamic effect were investigated numerically via computational fluid dynamics by using ANSYS 14.0 software. Three hemodynamics variables were analysed in this study which are wall shear stress (WSS), oscillatory shear index (OSI) and relative residence time (RRT). Each stent affect the hemodynamic within PDA differently. The higher percentage of TAWSS exposed in range of 0.5 Pa to 2 Pa is better shown by Closed Cell V stent with 25.4%. Type One stent shown a good result in OSI which has high percentages exposed below 0.2 with the value of 34%. Palmaz-Schatz stent present a preferable results in both WSS low, 1.2% (low the better) and RRT within range of 10 Pa^-1 at 97.7%. Thus, this study can be useful in stent selection for PDA stenting.
format Thesis
author Jamalruhanordin, Fara Lyana
author_facet Jamalruhanordin, Fara Lyana
author_sort Jamalruhanordin, Fara Lyana
title Arterial hemodynamics in patent ductus arteriosus stenting
title_short Arterial hemodynamics in patent ductus arteriosus stenting
title_full Arterial hemodynamics in patent ductus arteriosus stenting
title_fullStr Arterial hemodynamics in patent ductus arteriosus stenting
title_full_unstemmed Arterial hemodynamics in patent ductus arteriosus stenting
title_sort arterial hemodynamics in patent ductus arteriosus stenting
publishDate 2015
url http://eprints.utm.my/id/eprint/53856/1/FaraLyanaJamalruhanordinMFBME2015.pdf
http://eprints.utm.my/id/eprint/53856/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:85894
_version_ 1677781105590140928
score 13.18916