Determination of optical path difference of white light fibre interferometer using peak tracking method

The aim of this paper is to evaluate the peak tracking method for determination of optical path difference of a fibre interferometer. This study narros the scope for Mach-Zehnder configuration with neutral white LED as its light source. The peak tracking method is then applied on the interference sp...

Full description

Saved in:
Bibliographic Details
Main Authors: Ley, Hood Hong, Yahaya, Asiah, Munajat, Yusof
Format: Article
Language:English
Published: Penerbit UTM 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/52342/1/LeyHoodHong2014_Determinationofopticalpath.pdf
http://eprints.utm.my/id/eprint/52342/
http://dx.doi.org/10.11113/jt.v71.3860
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.52342
record_format eprints
spelling my.utm.523422018-09-17T04:08:05Z http://eprints.utm.my/id/eprint/52342/ Determination of optical path difference of white light fibre interferometer using peak tracking method Ley, Hood Hong Yahaya, Asiah Munajat, Yusof QC Physics The aim of this paper is to evaluate the peak tracking method for determination of optical path difference of a fibre interferometer. This study narros the scope for Mach-Zehnder configuration with neutral white LED as its light source. The peak tracking method is then applied on the interference spectrum recorded from the output port of the interferometer using a spectrometer, allowing the optical path difference to be computed. Accuracy of this method is greatly affected by the wavelength resolution of the detector, where the uncertainty of the result is smaller with higher wavelength resolution and the maximum measurable path difference was found to be about 0.6 mm Penerbit UTM 2014 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/52342/1/LeyHoodHong2014_Determinationofopticalpath.pdf Ley, Hood Hong and Yahaya, Asiah and Munajat, Yusof (2014) Determination of optical path difference of white light fibre interferometer using peak tracking method. Jurnal Teknologi, 71 (5). pp. 79-82. ISSN 0127-9696 http://dx.doi.org/10.11113/jt.v71.3860 DOI: 10.11113/jt.v71.3860
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic QC Physics
spellingShingle QC Physics
Ley, Hood Hong
Yahaya, Asiah
Munajat, Yusof
Determination of optical path difference of white light fibre interferometer using peak tracking method
description The aim of this paper is to evaluate the peak tracking method for determination of optical path difference of a fibre interferometer. This study narros the scope for Mach-Zehnder configuration with neutral white LED as its light source. The peak tracking method is then applied on the interference spectrum recorded from the output port of the interferometer using a spectrometer, allowing the optical path difference to be computed. Accuracy of this method is greatly affected by the wavelength resolution of the detector, where the uncertainty of the result is smaller with higher wavelength resolution and the maximum measurable path difference was found to be about 0.6 mm
format Article
author Ley, Hood Hong
Yahaya, Asiah
Munajat, Yusof
author_facet Ley, Hood Hong
Yahaya, Asiah
Munajat, Yusof
author_sort Ley, Hood Hong
title Determination of optical path difference of white light fibre interferometer using peak tracking method
title_short Determination of optical path difference of white light fibre interferometer using peak tracking method
title_full Determination of optical path difference of white light fibre interferometer using peak tracking method
title_fullStr Determination of optical path difference of white light fibre interferometer using peak tracking method
title_full_unstemmed Determination of optical path difference of white light fibre interferometer using peak tracking method
title_sort determination of optical path difference of white light fibre interferometer using peak tracking method
publisher Penerbit UTM
publishDate 2014
url http://eprints.utm.my/id/eprint/52342/1/LeyHoodHong2014_Determinationofopticalpath.pdf
http://eprints.utm.my/id/eprint/52342/
http://dx.doi.org/10.11113/jt.v71.3860
_version_ 1643653183653806080